AIR CONDITIONING SYSTEM > GENERAL



OUTLINE
  1. The automatic air conditioning system uses left and right independent temperature control and neural network control to enhance comfort.


SPECIFICATION
  1. Performance

    Heater
    Heater Output
    W
    5850
    Air Flow Volume
    m3/h
    380
    Power Consumption
    W
    220
    Cooler
    Cooling Capacity
    W
    6100
    Air Flow Volume
    m3/h
    530
    Power Consumption
    W
    260

  2. Ventilation and Heater Core

    Heater Radiator Unit Sub-assembly
    Type
    Straight Flow Aluminum (SFA) -II
    Size W x H x L
    mm (in.)
    201.5 x 150 x 27 (7.9 x 5.9 x 1.1)
    Fin Pitch
    mm (in.)
    1.5 (0.06)
    Blower with Fan Motor Sub-assembly
    Motor Type
    BMM - K70
    Fan Type
    Semi Sirocco
    Fan Size (Dia. x H)
    mm (in.)
    165 x 70 (6.5 x 2.8)

  3. Air Conditioning

    Cooler Condenser Assembly
    Type
    Multi-Flow (MF)-IV
    Size W x H x L
    mm (in.)
    726 x 261.4 x 22
    (28.6 x 10.3 x 0.9)
    Fin Pitch
    mm (in.)
    2.7 (0.11)
    Compressor with Motor Assembly
    Type
    ES27
    Compressor Oil Type
    cc
    ND11
    Refrigerant
    Type
    HFC 134a
    Charge Volume
    g
    480 to 580
    Evaporator
    Type
    Revolutionary super-slim Structure (RS)
    Size W x H x L
    mm (in.)
    266.3 x 251 x 38 (10.5 x 9.9 x 1.5)
    Fin Pitch
    mm (in.)
    2.6 (0.10)


MAIN FEATURES
  1. The air conditioning system has the following features:

    High Performance
    1. Neural network control is used so passengers can control the air conditioning accurately for maximum comfort.
    2. The Positive Temperature Coefficient (PTC) heater system is used. This system contains a PTC heater that heats the air that has passed through the heater radiator unit sub-assembly to ensure proper heater performance.
    Lightweight
    1. An air conditioning harness assembly with a built-in IC is used in a lightweight wire harness design to allow a reduced number of wires.
    2. The use of this connector means that pulse pattern type servo motors are used.
    Others
    The following parts are used to ensure high cooling performance while realizing a compact and lightweight construction.
    1. Semi-center Location Air Conditioning Unit
    2. Revolutionary Super-slim Structure (RS) Evaporator
    3. Straight Flow Aluminum (SFA)-II Heater Radiator Sub-assembly
    4. Multi-Flow (MF)-IV Sub-cool Condenser