DTC P0C76-523 Hybrid Battery System Discharge Time Too Long |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0C76 | 523 | Inverter voltage (VH) sensor offset malfunction |
|

| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0C76-523 only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit / Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit / Open |
| P06E6-164 | Sensor Power Supply "C" Circuit / Open |
| P0A1A-151, 658, 791 | Generator Control Module |
| P0A1B-786, 794 | Drive Motor "A" Control Module |
| P0A1D-148 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0AE7-224 | Hybrid Battery Precharge Contactor Control Circuit High |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P2511-149 | ECM/PCM Power Relay Sense Circuit Intermittent |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Any of the following DTCs are also output. | A |
| P0C76-523 only is output, or DTCs except the ones in the table below are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A90-251, 509 | Drive Motor "A" Performance |
| P0A92-261, 521 | Hybrid Generator Performance |
| P0C19-306 | Drive Motor "A" Torque Delivered Performance |
| P0E71-344 | Generator Torque Delivered Performance |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK POWER MANAGEMENT CONTROL ECU |
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-30 (HSDN) - I3-6 (E1) | Power switch on (IG) | Below 4.5 V |
| *a | Component with harness connected (Power Management Control ECU) |
Turn the power switch off.
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector A14 from the inverter with converter assembly.
Disconnect connector A38 and A39 from the power management control ECU.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.

| *a | Front view of wire harness connector (to Inverter with Converter Assembly) | *b | Rear view of wire harness connector (to Power Management Control ECU) |
| Tester Connection | Switch Condition | Specified Condition |
| A14-40 (HSDN) or A38-30 (HSDN) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-30 (HSDN) - A39-1 (IG2) | Power switch off | 10 kΩ or higher |
| A38-30 (HSDN) - A39-2 (IG2D) | Power switch off | 10 kΩ or higher |
| A38-30 (HSDN) - A39-3 (+B1) | Power switch off | 10 kΩ or higher |
| A38-30 (HSDN) - A38-4 (MREL) | Power switch off | 10 kΩ or higher |
| A14-40 (HSDN) - A14-30 (+B) | Power switch off | 10 kΩ or higher |
| A14-40 (HSDN) - A14-31 (+B2) | Power switch off | 10 kΩ or higher |
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 5.CHECK INVERTER WITH CONVERTER ASSEMBLY |
Check that the service plug grip is not installed.
Disconnect connector A14 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-40 (HSDN) - A14-30 (+B) | Power switch off | 5 kΩ or higher |
| A14-40 (HSDN) - A14-31 (+B2) | Power switch off | 5 kΩ or higher |
| *a | Component without harness connected (Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||