Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A7A-344    Generator Inverter Performance

for Preparation Click here


DESCRIPTION

For a description of the inverter .
If the MG1 torque execution value does not correspond to the torque command value from the MG ECU to MG1, the power management control ECU will store this DTC.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A7A
344
MG1 torque execution monitoring malfunction
  1. Hybrid vehicle transaxle assembly
  2. Inverter with converter assembly
  3. Wire harness or connector
  4. Power management control ECU

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AA6-526 .
Refer to the wiring diagram for DTC P321E-318 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    Only P0A7A-344 is output or P0A7A-344 and DTCs other than the ones in the table below are also output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes)*1
    Generator Control Module
    P0A1B (all INF codes)*1
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A60 (all INF codes)*1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes)*1
    Drive Motor "A" Phase W Current
    P0A72 (all INF codes)*1
    Generator Phase V Current
    P0A75 (all INF codes)*1
    Generator Phase W Current
    P0A78-266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808
    Drive Motor "A" Inverter Performance
    P0A7A-203, 325, 517, 518, 809, 810, 811
    Generator Inverter Performance
    P0A94-547, 548, 549, 554, 555, 556, 585, 587, 589, 590
    DC/DC Converter Performance
    P0AA6 (all INF codes)*1
    Hybrid Battery Voltage System Isolation Fault
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P3004-132
    High Voltage Power Resource

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0A7A-344 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

  1. Turn the power switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


2.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    Any of the following DTCs are also output.
    A
    Only P0A7A-344 is output or P0A7A-344 and DTCs other than the ones in the table below are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A78-306
    Drive Motor "A" Inverter Performance
    P0A90-251, 509
    Drive Motor "A" Performance

    HINT:
    When the DTCs listed in the table above are also output, there may be a short between the HSDN (MG shut down signal) circuit and power circuit.

  1. Turn the power switch off.



B
Go to step 4
A


3.CHECK POWER MANAGEMENT CONTROL ECU
  1. Turn the power switch on (IG).



    A252924E04
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-31 (HSDN) - I3-6 (E1)
    Power switch on (IG)
    Below 4.5 V

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

  1. Turn the power switch off.



NG
Go to step 7
OK


4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



  1. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

    NOTICE:
    Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.


    A258444E01

    OK:
    The connectors are connected securely and there are no contact pressure problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK


5.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258951
  1. Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.



    A258953
  1. Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

    Specified Condition:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

  1. Disconnect the generator cable from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the generator cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the generator cable to the inverter with converter assembly.

  1. Install the upper inverter cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258636
  1. Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258637E05
  1. Disconnect the generator cable and motor cable from the inverter with converter assembly.
    Text in Illustration 
    *1
    Generator Cable
    *2
    Motor Cable



    A258955E05
  1. Check MG1 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      o1-1 (W) - o1-3 (U)
      Power switch off
      59.1 to 67.5 mΩ
      o1-2 (V) - o1-1 (W)
      Power switch off
      59.1 to 67.5 mΩ
      o1-3 (U) - o1-2 (V)
      Power switch off
      62.1 to 70.5 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Generator Cable
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    o1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    o1-2 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    o1-3 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable and motor cable.

  1. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

7.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A14 from the inverter with converter assembly.

  1. Disconnect connector A39 from the power management control ECU.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A259927E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A14-40 (HSDN) or A39-31 (HSDN) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Rear view of wire harness connector
    (to Power Management Control ECU)

    NOTICE:
    Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-31 (HSDN) - A39-1 (IG2)
    Power switch off
    10 kΩ or higher
    A39-31 (HSDN) - A39-2 (IG2D)
    Power switch off
    10 kΩ or higher
    A39-31 (HSDN) - A39-5 (+B1)
    Power switch off
    10 kΩ or higher
    A39-31 (HSDN) - A39-6 (MREL)
    Power switch off
    10 kΩ or higher
    A14-40 (HSDN) - A14-30 (+B)
    Power switch off
    10 kΩ or higher
    A14-40 (HSDN) - A14-31 (+B2)
    Power switch off
    10 kΩ or higher

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.CHECK INVERTER WITH CONVERTER ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A14 from the inverter with converter assembly.



    A258450E04
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A14-40 (HSDN) - A14-30 (+B)
    Power switch off
    5 kΩ or higher
    A14-40 (HSDN) - A14-31 (+B2)
    Power switch off
    5 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)