DTC P0A7A-344 Generator Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A7A | 344 | MG1 torque execution monitoring malfunction |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Only P0A7A-344 is output or P0A7A-344 and DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-203, 325, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A94-547, 548, 549, 554, 555, 556, 585, 587, 589, 590 | DC/DC Converter Performance |
| P0AA6 (all INF codes)*1 | Hybrid Battery Voltage System Isolation Fault |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-132 | High Voltage Power Resource |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Any of the following DTCs are also output. | A |
| Only P0A7A-344 is output or P0A7A-344 and DTCs other than the ones in the table below are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A78-306 | Drive Motor "A" Inverter Performance |
| P0A90-251, 509 | Drive Motor "A" Performance |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK POWER MANAGEMENT CONTROL ECU |
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A39-31 (HSDN) - I3-6 (E1) | Power switch on (IG) | Below 4.5 V |
| *a | Component with harness connected (Power Management Control ECU) |
Turn the power switch off.
|
| ||||
| OK | |
| 4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

|
| ||||
| OK | |
| 5.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.
![]() |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
Disconnect the generator cable from the inverter with converter assembly.
Check for arc marks at the terminals for the generator cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the inverter with converter assembly.
Install the upper inverter cover.
|
| ||||
|
| ||||
| A | |
| 6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.
![]() |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *1 | Generator Cable |
| *2 | Motor Cable |
![]() |
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| o1-1 (W) - o1-3 (U) | Power switch off | 59.1 to 67.5 mΩ |
| o1-2 (V) - o1-1 (W) | Power switch off | 59.1 to 67.5 mΩ |
| o1-3 (U) - o1-2 (V) | Power switch off | 62.1 to 70.5 mΩ |
| *1 | Shield Ground |
| *a | Generator Cable (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| o1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| o1-2 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| o1-3 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the generator cable and motor cable.
Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).
|
| ||||
| OK | ||
| ||
| 7.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector A14 from the inverter with converter assembly.
Disconnect connector A39 from the power management control ECU.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-40 (HSDN) or A39-31 (HSDN) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector (to Power Management Control ECU) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A39-31 (HSDN) - A39-1 (IG2) | Power switch off | 10 kΩ or higher |
| A39-31 (HSDN) - A39-2 (IG2D) | Power switch off | 10 kΩ or higher |
| A39-31 (HSDN) - A39-5 (+B1) | Power switch off | 10 kΩ or higher |
| A39-31 (HSDN) - A39-6 (MREL) | Power switch off | 10 kΩ or higher |
| A14-40 (HSDN) - A14-30 (+B) | Power switch off | 10 kΩ or higher |
| A14-40 (HSDN) - A14-31 (+B2) | Power switch off | 10 kΩ or higher |
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 8.CHECK INVERTER WITH CONVERTER ASSEMBLY |
Check that the service plug grip is not installed.
Disconnect connector A14 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-40 (HSDN) - A14-30 (+B) | Power switch off | 5 kΩ or higher |
| A14-40 (HSDN) - A14-31 (+B2) | Power switch off | 5 kΩ or higher |
| *a | Component without harness connected (Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||