DTC P0A92-261 Hybrid Generator Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A92 | 261 | Generator magnetic force deterioration or same phase short circuit |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Only P0A92-261 is output or P0A92-261 and DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit / Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit / Open |
| P06E6-164 | Sensor Power Supply "C" Circuit / Open |
| P0A1A-151, 166, 658, 791 | Generator Control Module |
| P0A1B-198, 786, 794 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A51-174 | Drive Motor "A" Current Sensor Circuit |
| P0A7A-203 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0AA6 (all INF codes)*1 | Hybrid Battery Voltage System Isolation Fault |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range / Performance |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range / Performance |
| P0C19-306 | Drive Motor "A" Torque Delivered Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range / Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range / Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range / Performance |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range / Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P0E71-344 | Generator Torque Delivered Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range / Performance |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range / Performance |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range / Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range / Performance |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range / Performance |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range / Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range / Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range / Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit / Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3004-132 | High Voltage Power Resource |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
Turn the power switch off.
|
| ||||
| A | |
| 2.SIMULATION TEST |
Turn the power switch on (READY).
Leave the vehicle for 1 minute with the engine on (with MG1 rotating).
Connect the intelligent tester to the DLC3.
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A92-261 is output or no DTC is output. | A |
| Any DTCs other than P0A92-261 are output. | B |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

|
| ||||
| OK | |
| 4.CHECK POWER MANAGEMENT CONTROL ECU |
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-30 (HSDN) - I3-6 (E1) | Power switch on (IG) | Below 4.5 V |
| *a | Component with harness connected (Power Management Control ECU) |
Turn the power switch off.
|
| ||||
| OK | |
| 5.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.
![]() |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
Disconnect the generator cable from the inverter with converter assembly.
Check for arc marks at the terminals for the generator cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the inverter with converter assembly.
Install the upper inverter cover.
|
| ||||
|
| ||||
| A | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector A14 from the inverter with converter assembly.
Disconnect connector A38 and A39 from the power management control ECU.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.

| *a | Front view of wire harness connector (to Inverter with Converter Assembly) | *b | Rear view of wire harness connector (to Power Management Control ECU) |
| Tester Connection | Switch Condition | Specified Condition |
| A14-40 (HSDN) or A38-30 (HSDN) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-30 (HSDN) - A39-1 (IG2) | Power switch off | 10 kΩ or higher |
| A38-30 (HSDN) - A39-2 (IG2D) | Power switch off | 10 kΩ or higher |
| A38-30 (HSDN) - A39-3 (+B1) | Power switch off | 10 kΩ or higher |
| A38-30 (HSDN) - A38-4 (MREL) | Power switch off | 10 kΩ or higher |
| A14-40 (HSDN) - A14-30 (+B) | Power switch off | 10 kΩ or higher |
| A14-40 (HSDN) - A14-31 (+B2) | Power switch off | 10 kΩ or higher |
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 7.CHECK INVERTER WITH CONVERTER ASSEMBLY |
Check that the service plug grip is not installed.
Disconnect connector A14 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-40 (HSDN) - A14-30 (+B) | Power switch off | 5 kΩ or higher |
| A14-40 (HSDN) - A14-31 (+B2) | Power switch off | 5 kΩ or higher |
| *a | Component without harness connected (Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||