COOLING FAN ECU > ON-VEHICLE INSPECTION |
| 1. INSPECT COOLING FAN ECU |
Put the vehicle in the following conditions:
The power switch is off.
The coolant temperature is less than 92°C (198°F).
The auxiliary battery voltage is between 11 to 14 V.
The A/C switch is off.
Connect the pickup of a clamp-on ammeter over one of the two wires for the cooling fan motor.
Turn the power switch on (IG) and wait for approximately 10 seconds. Check that the fan stops.
Start the engine. Check that the fan stops with the engine idling.
Check that the fan operates when the A/C switch is turned on.
| Item | Specified Condition |
| Cooling fan motor | 10.6 to 16.6 A |
| No. 2 cooling fan motor | 10.6 to 16.6 A |
Check that the fan operates when the engine coolant temperature sensor connector is disconnected.
| Item | Specified Condition |
| Cooling fan motor | 10.6 to 16.6 A |
| No. 2 cooling fan motor | 10.6 to 16.6 A |
![]() |
After the engine is warmed up, check that the fan operates as shown in the illustration.