Home › Engine / Hybrid System › 2AR-FXE ENGINE CONTROL › INTEGRATION RELAY

INTEGRATION RELAY > INSPECTION

for Preparation Click here



1. INSPECT NO. 1 INTEGRATION RELAY



A334407E01


Text in Illustration 
*1
No. 1 Integration Relay
-
-


  1. EFI MAIN RELAY:



      A255141E01
    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      No. 1 Integration Relay

      Standard Resistance:

      Tester Connection
      Condition
      Specified Condition
      1A-8 - 1B-1
      Auxiliary battery voltage not applied between terminals 1C-7 and 1E-2
      10 kΩ or higher
      1A-8 - 1B-1
      Auxiliary battery voltage applied between terminals 1C-7 and 1E-2
      Below 1 Ω
      1C-3 - 1B-1
      1C-4 - 1B-1
      1C-9 - 1B-1
      1C-10 - 1B-1

      If the result is not as specified, replace the No. 1 integration relay.



  1. EFI MAIN2 RELAY:



      A255141E01
    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      No. 1 Integration Relay

      Standard Resistance:

      Tester Connection
      Condition
      Specified Condition
      1A-6 - 1D-1
      Auxiliary battery voltage not applied between terminals 1A-8 and 1E-2
      10 kΩ or higher
      1A-6 - 1D-1
      Auxiliary battery voltage applied between terminals 1A-8 and 1E-2
      Below 1 Ω
      1A-7 - 1D-1
      1C-6 - 1D-1

      If the result is not as specified, replace the No. 1 integration relay.



  1. IG2 RELAY:



      A255141E01
    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      No. 1 Integration Relay

      Standard Resistance:

      Tester Connection
      Condition
      Specified Condition
      1A-1 - 1D-3
      Auxiliary battery voltage not applied between terminals 1C-8 and 1E-2
      10 kΩ or higher
      1A-1 - 1D-3
      Auxiliary battery voltage applied between terminals 1C-8 and 1E-2
      Below 1 Ω
      1A-3 - 1D-3
      1C-1 - 1D-3
      1C-2 - 1D-3
      1C-5 - 1D-3

      If the result is not as specified, replace the No. 1 integration relay.