AIR CONDITIONING SYSTEM > SYSTEM DESCRIPTION |
| GENERAL |
The air conditioning system has the following controls.
| Control | Outline |
| Neural Network Control | This control is capable of performing complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship similar to that of a human brain. |
| Outlet Air Temperature Control | Based on the temperature set by the temperature control dial, neural network control calculates outlet air temperature based on input signals from various sensors. |
| Dual Control | The temperature settings for the driver and front passenger are controlled independently in order to provide separate vehicle interior temperatures for the right and left sides of the vehicle. Thus, air conditioning that accommodates the occupants' preferences has been realized. |
| Blower Control | Controls the blower motor with fan sub-assembly in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors. |
| Air Outlet Control | Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control. |
| In accordance with the engine coolant temperature, ambient air temperature, amount of sunlight, required blower, outlet temperature and vehicle speed conditions, this control automatically switches the blower outlet to foot and defroster mode to prevent the windows from becoming fogged up when the ambient air temperature is low. | |
| Air Inlet Control | Automatically controls the air inlet control damper to help achieve the calculated outlet air temperature that is required. |
| Drives the air inlet control servo motor according to the operation of the air inlet control switch and moves the dampers to the fresh or recirculation position. | |
| Electric Inverter Compressor Control | The air conditioning amplifier assembly calculates the target speed of the compressor based on the target evaporator temperature (which is calculated by the room temperature sensor, outside temperature sensor, and the automatic light control sensor (solar sensor)) and the actual evaporator temperature that is detected by the evaporator temperature sensor in order to control the compressor speed. |
| The air conditioning amplifier assembly calculates the target evaporator temperature, which includes corrections based on the room temperature sensor, outside temperature sensor, the automatic light control sensor (solar sensor), and evaporator temperature sensor. Accordingly, the air conditioning amplifier assembly controls the compressor speed to an extent that would not inhibit the proper cooling performance or defogging performance. | |
| Turns the air conditioning on automatically when the AUTO button is pressed when the blower is ON and the air conditioning is off. | |
| Decreases the compressor speed in order to ensure quietness when the vehicle is stopped or the engine is off. | |
| Defroster Control | Defroster control logic is used to improve defroster performance. |
| PTC Heater Control | When the hybrid system is operating (READY), and the blower with fan motor sub-assembly is turned on, the air conditioning amplifier assembly turns on the quick heater assembly if the conditions listed below are met. - Engine coolant temperature is below specified temperature. - Outside temperature is below specified temperature. - Tentative air mix damper opening angle is above the specified value (MAX HOT). |
| Rear Defogger Control | When the power switch is on (IG) and the rear defogger switch is pushed, the system is activated to keep the defogger heater on for approx. 15 minutes. |
| ECO Mode Control | When the ECO mode switch (eco switch assembly) is turned on, the air conditioning amplifier assembly limits the air conditioning system performance. |
| Diagnosis | A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier detects a problem with the air conditioning system. |
| NEURAL NETWORK CONTROL |

| MODE POSITION AND DAMPER OPERATION |
Mode Position and Damper Operation

| Control Damper | Operation Position | Damper Position | Operation |
| Air Inlet Control Damper | FRESH | A | Allows fresh air to enter. |
| RECIRCULATION | B | Causes internal air to recirculate. | |
| Air Mix Control Damper | MAX COLD to MAX HOT Temperature Setting | C - D - E (C' - D' - E') T - U - V | Varies the mixture ratio of warm air and cool air in order to regulate the temperature continuously between hot and cold. |
| Air Outlet Control Damper | DEF![]() | F, J, L, P, S, Y | Defrosts the windshield through the center defroster, side defroster, and side registers. |
FOOT / DEF![]() | G, J, L, P, Q, X | Defrosts the windshield through the center defroster, side defrosters, side registers, and rear center register, while air is also blown out from the front and rear footwell register ducts. | |
FOOT![]() | H, J, L, P, Q, X | Air blows out of the front and rear footwell register duct, and side registers. In addition, air blows out slightly from the center defroster and side defrosters. | |
BI-LEVEL![]() | I, K, N, O, R, X | Air blows out of the front and rear center registers, side registers and front and rear footwell registers ducts. | |
FACE![]() | I, K, M, O, S, W | Air blows out of the front and rear center registers, and side registers. |
| AIR OUTLETS AND AIRFLOW VOLUME |
Air Outlets and Airflow Volume

| MODE | Selection | Register | Footwell | Defroster | ||||||
| Automatic | Manual | CTR | SIDE | RR | FR | RR | CTR | SIDE | ||
| A | B | C | D | E | F | G | ||||
| FACE-U*1 | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
| B/L-U*2 | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
| FOOT-F*3 | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
| FOOT-R*4 | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |
| FOOT-D*5 | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |
| F/D | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
| DEF | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
| COMPRESSOR WITH MOTOR ASSEMBLY |
General
Along with the use of the hybrid system on this vehicle, an electric inverter compressor that is driven by a motor is used. The basic construction and operation of this compressor are the same as an ordinary scroll compressor, except that it is driven by an electric motor.
The Air Conditioning (A/C) inverter is integrated with the compressor.
The electric motor is actuated by 3-phase alternating current (244.8 V) supplied by the A/C inverter. As a result, the air conditioning control system on this vehicle is actuated without depending on the operation of the engine, thus realizing a comfortable air conditioning system and low fuel consumption.
Due to the use of an electric inverter compressor, the compressor speed can be controlled at the required speed calculated by the air conditioning amplifier assembly. Thus, the cooling and dehumidification performance and power consumption have been optimized.
Low-moisture permeation hoses are used for the suction and discharge hoses at the compressor in order to minimize the entry of moisture into the refrigeration cycle.
The compressor uses high-voltage alternating current. If a short or open circuit occurs in the compressor, the power management control ECU will cut off the A/C inverter circuit in order to stop the power supply to the compressor motor.
Compressor Speed Control
The air conditioning amplifier assembly calculates the target compressor speed based on the target evaporator temperature (calculated from the temperature control switch, room temperature sensor, ambient temperature sensor, and automatic light control sensor (solar sensor)) and the actual evaporator temperature detected by the evaporator temperature sensor. Then, the air conditioning amplifier assembly transmits the target speed to the power management control ECU. The power management control ECU controls the A/C inverter based on the target speed data in order to control the compressor to a speed that suits the operating condition of the air conditioning system.
The air conditioning amplifier assembly calculates the target evaporator temperature, which includes corrections based on the room temperature sensor, outside temperature sensor, automatic light control sensor (solar sensor), and evaporator temperature sensor. Accordingly, the air conditioning amplifier assembly controls the compressor speed to an extent that does not inhibit the proper cooling performance or defogging performance. As a result, comfort and low fuel consumption can be realized.
| EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR) |
| BLOWER MOTOR WITH FAN SUB-ASSEMBLY |
| BUS CONNECTOR (AIR CONDITIONING HARNESS ASSEMBLY) |
BUS connectors are used in the wire harness that connects the servo motors to the air conditioning amplifier assembly.

Each BUS connector has a built-in communication/driver IC which communicates with the air conditioning amplifier assembly, actuates the servo motor, and has a position detection function. This enables bus communication for the servo motor wire harness, for a more lightweight construction and a reduced number of wires.

| SERVO MOTOR |

| PTC HEATER |
General
The quick heater assembly is located above the heater core in the air conditioning unit.
The quick heater assembly consists of a PTC element, aluminum fins, and brass plates. When current is applied to the PTC element, it generates heat to warm the air that passes through the unit.

| *1 | Quick Heater Assembly | *2 | Brass Plate |
| *3 | PTC Element | *4 | Aluminum Fin |
Quick Heater Assembly Operating Conditions
The quick heater assembly is turned on and off by the air conditioning amplifier assembly in accordance with the engine coolant temperature, ambient temperature, temperature setting, and electrical load (generator power ratio).
| ION GENERATOR |
The ion generator is controlled by the air conditioning assembly and operates in accordance with the blower motor with fan sub-assembly.
The ion generator assembly emits "nanoe" ions that are electrically charged and encapsulated with water. The ions are discharged into the cabin through the driver side vent to provide skin-friendly clean air.*1

| *1 | Ion Generator Assembly | - | - |
| *a | Common Negative Ion | *b | "nanoe" |
| *c | H2O | *d | Electron |
| ECO MODE CONTROL |
Under the control of eco mode, the air conditioning amplifier assembly restricts the air conditioning system performance under specified conditions, thus improving fuel economy.
| ROOM TEMPERATURE SENSOR (COOLER THERMISTOR) |
| AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY) |
| SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR) |
The solar sensor (automatic light control sensor) consists of a photo diode, two amplifier circuits for the solar sensor (automatic light control sensor), and frequency converter circuit for the light control sensor.
The solar sensor (automatic light control sensor) detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight from the LH and RH sides (2 directions) and outputs these sunlight strength signals to the air conditioning amplifier assembly.

| AIR CONDITIONING PRESSURE SENSOR |