Home › Power Source / Network › 2AR-FXE BATTERY / CHARGING › BATTERY THERMOMETER SENSOR

BATTERY THERMOMETER SENSOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT AUXILIARY BATTERY THERMOMETER SENSOR


    E162241E31
  1. Disconnect the connector from the auxiliary battery thermometer sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    1 - 2
    15°C (59°F)
    2.45 to 2.88 kΩ
    1 - 2
    20°C (68°F)
    1.95 to 2.30 kΩ
    1 - 2
    25°C (77°F)
    1.60 to 1.80 kΩ
    1 - 2
    30°C (86°F)
    1.28 to 1.47 kΩ
    1 - 2
    35°C (95°F)
    1.00 to 1.22 kΩ
    1 - 2
    40°C (104°F)
    0.80 to 1.00 kΩ
    1 - 2
    45°C (113°F)
    0.65 to 0.85 kΩ
    1 - 2
    50°C (122°F)
    0.50 to 0.70 kΩ
    1 - 2
    55°C (131°F)
    0.44 to 0.60 kΩ
    1 - 2
    60°C (140°F)
    0.36 to 0.50 kΩ

    Text in Illustration 
    *a
    Component without harness connected
    (Auxiliary Battery Thermometer Sensor)
    *b
    Sensing Portion
    *c
    Resistance (kΩ)
    *d
    Temperature °C (°F)
    *e
    Allowable Range

    NOTICE:
    1. Hold the sensor only by its connector. Touching the sensor may change the resistance value.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    If the resistance is not as specified, replace the auxiliary battery thermometer sensor.