DTC P0A7A-122 Generator Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A7A | 122 | Generator inverter fail signal detection (overcurrent due to system malfunction) |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A7A-122 is set before any of the DTCs in the table below are set. | A |
| Any of the DTCs in the table 1 below are set before P0A7A-122 is set. | B |
| Any of the DTCs in the table 2 below are set before P0A7A-122 is set. | C |
| DTC No. | Relevant Diagnosis |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P3004-803 | High Voltage Power Resource |
| DTC No. | Relevant Diagnosis |
| P3011-123, P3012-123, P3013-123, P3014-123, P3015-123, P3016-123, P3017-123, P3018-123, P3019-123, P3020-123, P3021-123, P3022-123, P3023-123, P3024-123, P3025-123, P3026-123, P3027-123 | Battery Block # Becomes Weak |
| P0A9C-123 | Hybrid Battery Temperature Sensor "A" Range / Performance |
| P0A9D-123 | Hybrid Battery Temperature Sensor "A" Circuit Low |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0AC0-123 | Hybrid Battery Pack Current Sensor Circuit Range/Performance |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High |
| P0AC6-123 | Hybrid Battery Temperature Sensor "B" Range/Performance |
| P0AC7-123 | Hybrid Battery Temperature Sensor "B" Circuit Low |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACB-123 | Hybrid Battery Temperature Sensor "C" Range / Performance |
| P0ACC-123 | Hybrid Battery Temperature Sensor "C" Circuit Low |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AFC-123 | Hybrid Battery Pack Sensor Module |
| P3065-123 | Hybrid Battery Temperature Sensor Range/Performance Stuck "A" |
| P308A-123 | Hybrid Battery Voltage Sensor All Circuits Low |
Turn the power switch off.
|
| ||||
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A7A-203 is not output. | A |
| P0A7A-203 is also output. | B |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A7A-122 only is output, or DTCs except the ones in the tables below are also output. | A |
| Any of the following DTCs including pending DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 166, 517, 658, 791, 809 | Generator Control Module |
| P0A1B-198, 503, 505, 547, 554, 786, 794, 806 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500, 504, 506, 549, 556, 808 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513, 518, 811 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-279, 287, 548, 555, 807 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 810 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range/Performance |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range/Performance |
| P0C19-306 | Drive Motor "A" Torque Delivered Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range/Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range/Performance |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range/Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P0E71-344 | Generator Torque Delivered Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range/Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range/Performance |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range/Performance |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range/Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range/Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range/Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3004-803 | Power Cable Malfunction |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 166, 517, 658, 791, 809 | Generator Control Module |
| P0A1B-198, 503, 505, 547, 554, 786, 794, 806 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500, 504, 506, 549, 556, 808 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513, 518, 811 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-279, 287, 548, 555, 807 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 810 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range/Performance |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range/Performance |
| P0C19-306 | Drive Motor "A" Torque Delivered Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range/Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range/Performance |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range/Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3004-803 | Power Cable Malfunction |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
Turn the power switch off.
|
| ||||
| A | |
| 4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-7 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-2 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-3 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 6.CHECK GENERATOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - E1-7 (GRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-2 (GSN) - E1-8 (GSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-3 (GCS) - E1-9 (GCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) or E1-7 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E1-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E1-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-11 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-5 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-12 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-13 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 8.CHECK MOTOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - E1-11 (MRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-5 (MSN) - E1-12 (MSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-6 (MCS) - E1-13 (MCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) or E1-11 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E1-12 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E1-13 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 9.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.
![]() |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
Disconnect the generator cable from the inverter with converter assembly.
Check for arc marks at the terminals for the generator cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the inverter with converter assembly.
Install the upper inverter cover.
|
| ||||
|
| ||||
| A | |
| 10.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.
![]() |
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
Disconnect the motor cable from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable to the inverter with converter assembly.
Install the upper inverter cover.
|
| ||||
|
| ||||
| A | |
| 11.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.
![]() |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *1 | Generator Cable |
| *2 | Motor Cable |
![]() |
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| o3-1 (W) - o3-3 (U) | Power switch off | 59.1 to 67.5 mΩ |
| o3-2 (V) - o3-1 (W) | Power switch off | 59.1 to 67.5 mΩ |
| o3-3 (U) - o3-2 (V) | Power switch off | 62.1 to 70.5 mΩ |
| *1 | Shield Ground |
| *a | Generator Cable (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| o3-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| o3-2 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| o3-3 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the generator cable and motor cable.
Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).
|
| ||||
| OK | |
| 12.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.
![]() |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *1 | Generator Cable |
| *2 | Motor Cable |
![]() |
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| n3-1 (W) - n3-3 (U) | Power switch off | 71.4 to 81.0 mΩ |
| n3-2 (V) - n3-1 (W) | Power switch off | 71.4 to 81.0 mΩ |
| n3-3 (U) - n3-2 (V) | Power switch off | 74.4 to 84.1 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| n3-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| n3-2 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| n3-3 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the generator cable and motor cable.
Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).
|
| ||||
| OK | |
| 13.CHECK FUSE (INV) |
![]() |
Remove the INV fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| INV fuse terminal | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV fuse |
Install the INV fuse.
|
| ||||
| OK | |
| 14.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT) |
Check that the service plug grip is not installed.
Disconnect connector A14 from inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-10 (GND1) - Body ground | Power switch off | Below 1 Ω |
| A14-11 (GND2) - Body ground | Power switch off | Below 1 Ω |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-30 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| A14-31 (+B2) - Body ground | Power switch on (IG) | 11 to 14 V |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 15.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector A38 from the power management control ECU.
Disconnect connector A14 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-34 (HTM+) - A14-9 (HTM+) | Power switch off | Below 1 Ω |
| A38-33 (HTM-) - A14-20 (HTM-) | Power switch off | Below 1 Ω |
| A38-21 (MTH+) - A14-8 (MTH+) | Power switch off | Below 1 Ω |
| A38-20 (MTH-) - A14-19 (MTH-) | Power switch off | Below 1 Ω |
| A38-32 (REQ+) - A14-26 (REQ+) | Power switch off | Below 1 Ω |
| A38-31 (REQ-) - A14-37 (REQ-) | Power switch off | Below 1 Ω |
| A38-29 (CLK+) - A14-7 (CLK+) | Power switch off | Below 1 Ω |
| A38-28 (CLK-) - A14-18 (CLK-) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| A38-34 (HTM+) or A14-9 (HTM+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-33 (HTM-) or A14-20 (HTM-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-21 (MTH+) or A14-8 (MTH+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-20 (MTH-) or A14-19 (MTH-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-32 (REQ+) or A14-26 (REQ+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-31 (REQ-) or A14-37 (REQ-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-29 (CLK+) or A14-7 (CLK+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-28 (CLK-) or A14-18 (CLK-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
| *b | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-34 (HTM+) or A14-9 (HTM+) - Body ground | Power switch on (IG) | Below 1 V |
| A38-33 (HTM-) or A14-20 (HTM-) - Body ground | Power switch on (IG) | Below 1 V |
| A38-21 (MTH+) or A14-8 (MTH+) - Body ground | Power switch on (IG) | Below 1 V |
| A38-20 (MTH-) or A14-19 (MTH-) - Body ground | Power switch on (IG) | Below 1 V |
| A38-32 (REQ+) or A14-26 (REQ+) - Body ground | Power switch on (IG) | Below 1 V |
| A38-31 (REQ-) or A14-37 (REQ-) - Body ground | Power switch on (IG) | Below 1 V |
| A38-29 (CLK+) or A14-7 (CLK+) - Body ground | Power switch on (IG) | Below 1 V |
| A38-28 (CLK-) or A14-18 (CLK-) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 16.CHECK POWER MANAGEMENT CONTROL ECU |
Disconnect connector A38 from the power management control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-34 (HTM+) - A38-33 (HTM-) | Power switch off | 80 to 170 Ω |
| A38-21 (MTH+) - A38-20 (MTH-) | Power switch off | 80 to 170 Ω |
| A38-32 (REQ+) - A38-31 (REQ-) | Power switch off | 80 to 170 Ω |
| A38-29 (CLK+) - A38-28 (CLK-) | Power switch off | 80 to 170 Ω |
| *a | Component without harness connected (Power Management Control ECU) |
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 17.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 18.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 19.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 20.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - E13-1 (GRF) | Power switch off | Below 1 Ω |
| E1-7 (GRFG) - E13-5 (GRFG) | Power switch off | Below 1 Ω |
| E1-2 (GSN) - E13-2 (GSN) | Power switch off | Below 1 Ω |
| E1-8 (GSNG) - E13-6 (GSNG) | Power switch off | Below 1 Ω |
| E1-3 (GCS) - E13-3 (GCS) | Power switch off | Below 1 Ω |
| E1-9 (GCSG) - E13-7 (GCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) or E13-1 (GRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-7 (GRFG) or E13-5 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E13-2 (GSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-8 (GSNG) or E13-6 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E13-3 (GCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-9 (GCSG) or E13-7 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 21.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 22.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - E12-1 (MRF) | Power switch off | Below 1 Ω |
| E1-11 (MRFG) - E12-4 (MRFG) | Power switch off | Below 1 Ω |
| E1-5 (MSN) - E12-2 (MSN) | Power switch off | Below 1 Ω |
| E1-12 (MSNG) - E12-5 (MSNG) | Power switch off | Below 1 Ω |
| E1-6 (MCS) - E12-3 (MCS) | Power switch off | Below 1 Ω |
| E1-13 (MCSG) - E12-6 (MCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) or E12-1 (MRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-11 (MRFG) or E12-4 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E12-2 (MSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-12 (MSNG) or E12-5 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E12-3 (MCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-13 (MCSG) or E12-6 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 23.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - INV FUSE) |
Check that the service plug grip is not installed.
Disconnect connector A14 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-30 (+B) - Body ground | Power switch off | 10 kΩ or higher |
| A14-31 (+B2) - Body ground | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 24.REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| NEXT | ||
| ||
| 25.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | ||
| ||