DTC P0A94-127 DC / DC Converter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A94 | 127 | Boost converter overvoltage signal detection (overvoltage due to system malfunction) |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A94-127 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-113, 128, 266, 267, 279, 284, 286, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-122, 130, 322, 324, 325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-172, 442, 547, 548, 549, 553, 554, 555, 556, 557, 564, 585, 587, 589, 590 | DC / DC Converter Performance |
| P0AA6-526 | Hybrid Battery Voltage System Isolation Fault |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-803 | High Voltage Power Resource |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-7 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-2 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-3 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 4.CHECK GENERATOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - E1-7 (GRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-2 (GSN) - E1-8 (GSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-3 (GCS) - E1-9 (GCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) or E1-7 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E1-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E1-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-11 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-5 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-12 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-13 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 6.CHECK MOTOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - E1-11 (MRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-5 (MSN) - E1-12 (MSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-6 (MCS) - E1-13 (MCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) or E1-11 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E1-12 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E1-13 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 7.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.
![]() |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
Disconnect the generator cable from the inverter with converter assembly.
Check for arc marks at the terminals for the generator cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the inverter with converter assembly.
Install the upper inverter cover.
|
| ||||
|
| ||||
| A | |
| 8.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.
![]() |
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
Disconnect the motor cable from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable to the inverter with converter assembly.
Install the upper inverter cover.
|
| ||||
|
| ||||
| A | |
| 9.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.
![]() |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *1 | Generator Cable |
| *2 | Motor Cable |
![]() |
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| o1-1 (W) - o1-3 (U) | Power switch off | 59.1 to 67.5 mΩ |
| o1-2 (V) - o1-1 (W) | Power switch off | 59.1 to 67.5 mΩ |
| o1-3 (U) - o1-2 (V) | Power switch off | 62.1 to 70.5 mΩ |
| *1 | Shield Ground |
| *a | Generator Cable (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| o1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| o1-2 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| o1-3 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the generator cable and motor cable.
Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).
|
| ||||
| OK | |
| 10.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.
![]() |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *1 | Generator Cable |
| *2 | Motor Cable |
![]() |
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| n1-1 (W) - n1-3 (U) | Power switch off | 71.4 to 81.0 mΩ |
| n1-2 (V) - n1-1 (W) | Power switch off | 71.4 to 81.0 mΩ |
| n1-3 (U) - n1-2 (V) | Power switch off | 74.4 to 84.1 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| n1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| n1-2 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| n1-3 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the generator cable and motor cable.
Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).
|
| ||||
| OK | |
| 11.CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the connector cover assembly from the inverter with converter assembly.
![]() |
Check that the bolt for the No. 4 floor wire is tightened to the specified torque, the No. 4 floor wire is connected securely, and there are no contact problems.
Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.
Check for arc marks at the bolt and terminals for the No. 4 floor wire.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the No. 4 floor wire to the inverter with converter assembly.
Install the connector cover assembly.
|
| ||||
|
| ||||
| A | |
| 12.CHECK SERVICE PLUG GRIP (CONNECTION CONDITION) |
Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.
|
| ||||
| OK | |
| 13.INSPECT SERVICE PLUG GRIP |
Remove the service plug drip.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Service plug grip terminals | Always | Below 1 Ω |
| *1 | Service plug grip |
Install the service plug drip.
|
| ||||
| OK | |
| 14.CHECK NO. 4 FLOOR WIRE |
Check that the service plug grip is not installed.
Remove the No. 4 hybrid battery shield panel .
![]() |
Disconnect connectors Q2 and Q3 of the No. 4 floor wire from the hybrid battery junction block assembly.
![]() |
Remove the connector cover assembly from the inverter with converter assembly.
![]() |
Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| Q1-1 (CBI) - Q2-1 (CBI) (Positive terminal) | Power switch off | Below 1 Ω |
| Q1-2 (CEI) - Q3-1 (CEI) (Negative terminal) | Power switch off | Below 1 Ω |
| *1 | Shield Ground |
| *a | No. 4 Floor Wire (Inverter with Converter Assembly Side) |
| *b | No. 4 Floor Wire (Hybrid Battery Junction Block Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| Q2-1 (CBI) - Body ground and shielded ground | Power switch off | 10 MΩ or higher |
| Q3-1 (CEI) - Body ground and shielded ground | Power switch off | 10 MΩ or higher |
| Q2-1 (CBI) - Q3-1 (CEI) | Power switch off | 10 MΩ or higher |
Connect the No. 4 floor wire to the hybrid battery junction block assembly.
Connect the No. 4 floor wire to the inverter with converter assembly.
Install the connector cover assembly.
Install the No. 4 hybrid battery shield panel.
|
| ||||
| OK | |
| 15.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB) |
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-1 (+) - Q2-1 (CBI) | Auxiliary battery voltage is not applied between terminals O9-1 (SMRB) and O9-2 (GND) | 10 kΩ or higher |
| A-1 (+) - Q2-1 (CBI) | Auxiliary battery voltage is applied between terminals O9-1 (SMRB) and O9-2 (GND) | Below 1 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O9-1 (SMRB) - O9-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
Install the hybrid battery junction block assembly.
|
| ||||
| OK | |
| 16.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRG) |
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| q1-1 (-) - Q3-1 (CEI) | Auxiliary battery voltage is not applied between terminals O9-3 (SMRG) and O9-2 (GND) | 10 kΩ or higher |
| q1-1 (-) - Q3-1 (CEI) | Auxiliary battery voltage is applied between terminals O9-3 (SMRG) and O9-2 (GND) | Below 1 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O9-3 (SMRG) - O9-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
Install the hybrid battery junction block assembly.
|
| ||||
| OK | |
| 17.CHECK FUSE (INV) |
![]() |
Remove the INV fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| INV fuse terminal | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV fuse |
Install the INV fuse.
|
| ||||
| OK | |
| 18.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT) |
Check that the service plug grip is not installed.
Disconnect connector A14 from inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-10 (GND1) - Body ground | Power switch off | Below 1 Ω |
| A14-11 (GND2) - Body ground | Power switch off | Below 1 Ω |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-30 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| A14-31 (+B2) - Body ground | Power switch on (IG) | 11 to 14 V |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 19.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector A39 from the power management control ECU.
Disconnect connector A14 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A39-24 (HTM+) - A14-9 (HTM+) | Power switch off | Below 1 Ω |
| A39-25 (HTM-) - A14-20 (HTM-) | Power switch off | Below 1 Ω |
| A39-30 (MTH+) - A14-8 (MTH+) | Power switch off | Below 1 Ω |
| A39-29 (MTH-) - A14-19 (MTH-) | Power switch off | Below 1 Ω |
| A39-33 (REQ+) - A14-26 (REQ+) | Power switch off | Below 1 Ω |
| A39-32 (REQ-) - A14-37 (REQ-) | Power switch off | Below 1 Ω |
| A39-21 (CLK+) - A14-7 (CLK+) | Power switch off | Below 1 Ω |
| A39-20 (CLK-) - A14-18 (CLK-) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| A39-24 (HTM+) or A14-9 (HTM+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-25 (HTM-) or A14-20 (HTM-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-30 (MTH+) or A14-8 (MTH+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-29 (MTH-) or A14-19 (MTH-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-33 (REQ+) or A14-26 (REQ+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-32 (REQ-) or A14-37 (REQ-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-21 (CLK+) or A14-7 (CLK+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-20 (CLK-) or A14-18 (CLK-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
| *b | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A39-24 (HTM+) or A14-9 (HTM+) - Body ground | Power switch on (IG) | Below 1 V |
| A39-25 (HTM-) or A14-20 (HTM-) - Body ground | Power switch on (IG) | Below 1 V |
| A39-30 (MTH+) or A14-8 (MTH+) - Body ground | Power switch on (IG) | Below 1 V |
| A39-29 (MTH-) or A14-19 (MTH-) - Body ground | Power switch on (IG) | Below 1 V |
| A39-33 (REQ+) or A14-26 (REQ+) - Body ground | Power switch on (IG) | Below 1 V |
| A39-32 (REQ-) or A14-37 (REQ-) - Body ground | Power switch on (IG) | Below 1 V |
| A39-21 (CLK+) or A14-7 (CLK+) - Body ground | Power switch on (IG) | Below 1 V |
| A39-20 (CLK-) or A14-18 (CLK-) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 20.CHECK POWER MANAGEMENT CONTROL ECU |
Disconnect connector A39 from the power management control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A39-24 (HTM+) - A39-25 (HTM-) | Power switch off | 80 to 170 Ω |
| A39-30 (MTH+) - A39-29 (MTH-) | Power switch off | 80 to 170 Ω |
| A39-33 (REQ+) - A39-32 (REQ-) | Power switch off | 80 to 170 Ω |
| A39-21 (CLK+) - A39-20 (CLK-) | Power switch off | 80 to 170 Ω |
| *a | Component without harness connected (Power Management Control ECU) |
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 21.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 22.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 23.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 24.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - E13-1 (GRF) | Power switch off | Below 1 Ω |
| E1-7 (GRFG) - E13-5 (GRFG) | Power switch off | Below 1 Ω |
| E1-2 (GSN) - E13-2 (GSN) | Power switch off | Below 1 Ω |
| E1-8 (GSNG) - E13-6 (GSNG) | Power switch off | Below 1 Ω |
| E1-3 (GCS) - E13-3 (GCS) | Power switch off | Below 1 Ω |
| E1-9 (GCSG) - E13-7 (GCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) or E13-1 (GRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-7 (GRFG) or E13-5 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E13-2 (GSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-8 (GSNG) or E13-6 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E13-3 (GCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-9 (GCSG) or E13-7 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 25.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 26.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - E12-1 (MRF) | Power switch off | Below 1 Ω |
| E1-11 (MRFG) - E12-4 (MRFG) | Power switch off | Below 1 Ω |
| E1-5 (MSN) - E12-2 (MSN) | Power switch off | Below 1 Ω |
| E1-12 (MSNG) - E12-5 (MSNG) | Power switch off | Below 1 Ω |
| E1-6 (MCS) - E12-3 (MCS) | Power switch off | Below 1 Ω |
| E1-13 (MCSG) - E12-6 (MCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) or E12-1 (MRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-11 (MRFG) or E12-4 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E12-2 (MSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-12 (MSNG) or E12-5 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E12-3 (MCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-13 (MCSG) or E12-6 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 27.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - INV FUSE) |
Check that the service plug grip is not installed.
Disconnect connector A14 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A14-30 (+B) - Body ground | Power switch off | 10 kΩ or higher |
| A14-31 (+B2) - Body ground | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 28.REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| NEXT | ||
| ||
| 29.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | ||
| ||