DTC    P0A94-127    DC / DC Converter Performance

for Preparation Click here


DESCRIPTION

For a description of the boost converter .
If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the power management control ECU.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A94
127
Boost converter overvoltage signal detection (overvoltage due to system malfunction)
  1. Hybrid battery junction block assembly
  2. Inverter with converter assembly
  3. Service plug grip
  4. No. 4 Floor wire
  5. Hybrid vehicle transaxle assembly
  6. Wire harness or connector
  7. INV fuse
  8. Power management control ECU

WIRING DIAGRAM

Refer to the wiring diagram for DTC P1CAC-200 .
Refer to the wiring diagram for DTC P0AA6-526 .
Refer to the wiring diagram for DTC P324E-788 .
Refer to the wiring diagram for DTC U0110-159 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A94-127 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P06B0-163
    Sensor Power Supply "A" Circuit / Open
    P06D6-511
    Sensor Reference Voltage "F" Circuit / Open
    P06E6-164
    Sensor Power Supply "C" Circuit / Open
    P0A1A-151, 166, 517, 658, 791, 809
    Generator Control Module
    P0A1B-198, 503, 505, 547, 554, 786, 794, 806
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500, 504, 506, 549, 556, 808
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513, 518, 811
    Generator Position Sensor Circuit Range / Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A78-113, 128, 279, 284, 286, 287, 548, 555, 807
    Drive Motor "A" Inverter Performance
    P0A7A-122, 130, 322, 324, 325, 810
    Generator Inverter Performance
    P0A90-509
    Drive Motor "A" Performance
    P0A92-521
    Hybrid Generator Performance
    P0A94-172, 553, 557
    DC / DC Converter Performance
    P0AA6 (all INF codes)*1
    Hybrid Battery Voltage System Isolation Fault
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0BEA-290
    Drive Motor "A" Phase V Current Sensor Circuit Range / Performance
    P0BEE-298
    Drive Motor "A" Phase V Current Sensor Circuit Range / Performance
    P0C19-306
    Drive Motor "A" Torque Delivered Performance
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P0CA3-442
    DC/DC Converter Step Up Voltage Performance
    P0D2E-586
    Drive Motor "A" Inverter Voltage Sensor Circuit Range / Performance
    P0D2F-266
    Drive Motor "A" Inverter Voltage Sensor Circuit Low
    P0D30-267
    Drive Motor "A" Inverter Voltage Sensor Circuit High
    P0E05-328
    Generator Phase V Current Sensor Circuit Range / Performance
    P0E09-336
    Generator Phase W Current Sensor Circuit Range / Performance
    P0E32-564, 585
    DC/DC Converter Voltage Sensor "A" Range / Performance
    P0E33-589
    DC/DC Converter Voltage Sensor "A" Low
    P0E34-590
    DC/DC Converter Voltage Sensor "A" High
    P0E71-344
    Generator Torque Delivered Performance
    P1C2A-155
    Generator A/D Converter Circuit
    P1C2B-192
    Drive Motor "A" A/D Converter Circuit
    P1C2D-587
    Hybrid Battery Voltage / DC/DC Converter Voltage Correlation
    P1C3C-294
    Drive Motor "A" Phase V Current Sensor Correlation
    P1C3D-302
    Drive Motor "A" Phase W Current Sensor Correlation
    P1C3E-333
    Generator Phase V Current Sensor Correlation
    P1C3F-341
    Generator Phase W Current Sensor Correlation
    P1C4A-288
    Drive Motor "A" Phase V Current Sensor Sub Circuit Range / Performance
    P1C4F-296
    Drive Motor "A" Phase W Current Sensor Sub Circuit Range / Performance
    P1C54-326
    Generator Phase V Current Sensor Sub Circuit Range / Performance
    P1C59-334
    Generator Phase W Current Sensor Sub Circuit Range / Performance
    P1C6D-501
    Drive Motor "A" Phase V Current Sensor Offset Range / Performance
    P1C6E-502
    Drive Motor "A" Phase W Current Sensor Offset Range / Performance
    P1C71-515
    Generator Phase V Current Sensor Offset Range / Performance
    P1C72-516
    Generator Phase W Current Sensor Offset Range / Performance
    P1C73-512
    Sensor Standard Voltage "F" Circuit / Open
    P1CA6-156
    Generator Control Module Malfunction
    P1CA7-193
    Drive Motor Control Module Malfunction
    P1CAC-200
    Generator Position Sensor Angle Malfunction
    P1CAD-168
    Drive Motor "A" Position Sensor Angle Malfunction
    P1CAF-792
    Generator Position Sensor REF Signal Cycle Malfunction
    P1CB0-795
    Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
    P1CB2-793
    Generator Position Sensor REF Signal Stop Malfunction
    P1CB3-796
    Drive Motor "A" Position Sensor REF Signal Stop Malfunction
    P3004-803
    High Voltage Power Resource
    P3133-659
    Communication Error from Generator to Drive Motor "A"
    P3134-661
    Communication Error from Drive Motor "A" to Generator

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0A94-127 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

  1. Turn the power switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



  1. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

    NOTICE:
    Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.


    A258444E01

    OK:
    The connectors are connected securely and there are no contact pressure problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK


3.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector E1 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A259709E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E1-1 (GRF) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-7 (GRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-2 (GSN) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-8 (GSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-3 (GCS) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-9 (GCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK GENERATOR RESOLVER

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector E1 from the inverter with converter assembly.



    A259709E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    E1-1 (GRF) - E1-7 (GRFG)
    Power switch off
    4.2 to 12.5 Ω
    E1-2 (GSN) - E1-8 (GSNG)
    Power switch off
    9.8 to 20.1 Ω
    E1-3 (GCS) - E1-9 (GCSG)
    Power switch off
    9.8 to 20.1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    E1-1 (GRF) or E1-7 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-2 (GSN) or E1-8 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-3 (GCS) or E1-9 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 23
OK


5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector E1 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A259709E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E1-4 (MRF) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-11 (MRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-5 (MSN) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-12 (MSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-6 (MCS) - Body ground
    Power switch on (IG)
    Below 1 V
    E1-13 (MCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK MOTOR RESOLVER

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector E1 from the inverter with converter assembly.



    A259709E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    E1-4 (MRF) - E1-11 (MRFG)
    Power switch off
    4.2 to 12.5 Ω
    E1-5 (MSN) - E1-12 (MSNG)
    Power switch off
    9.8 to 20.1 Ω
    E1-6 (MCS) - E1-13 (MCSG)
    Power switch off
    9.8 to 20.1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    E1-4 (MRF) or E1-11 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-5 (MSN) or E1-12 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-6 (MCS) or E1-13 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 25
OK


7.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258951
  1. Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.



    A258953
  1. Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

    Specified Condition:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

  1. Disconnect the generator cable from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the generator cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the generator cable to the inverter with converter assembly.

  1. Install the upper inverter cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


8.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258952
  1. Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258954
  1. Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

    Specified Condition:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

  1. Disconnect the motor cable from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the motor cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable to the inverter with converter assembly.

  1. Install the upper inverter cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


9.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258636
  1. Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258637E10
  1. Disconnect the generator cable and motor cable from the inverter with converter assembly.
    Text in Illustration 
    *1
    Generator Cable
    *2
    Motor Cable



    A258955E15
  1. Check MG1 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      o3-1 (W) - o3-3 (U)
      Power switch off
      59.1 to 67.5 mΩ
      o3-2 (V) - o3-1 (W)
      Power switch off
      59.1 to 67.5 mΩ
      o3-3 (U) - o3-2 (V)
      Power switch off
      62.1 to 70.5 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Generator Cable
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    o3-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    o3-2 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    o3-3 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable and motor cable.

  1. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK


10.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258636
  1. Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258637E10
  1. Disconnect the generator cable and motor cable from the inverter with converter assembly.
    Text in Illustration 
    *1
    Generator Cable
    *2
    Motor Cable



    A258955E16
  1. Check MG2 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      n3-1 (W) - n3-3 (U)
      Power switch off
      71.4 to 81.0 mΩ
      n3-2 (V) - n3-1 (W)
      Power switch off
      71.4 to 81.0 mΩ
      n3-3 (U) - n3-2 (V)
      Power switch off
      74.4 to 84.1 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Motor Cable
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    n3-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    n3-2 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    n3-3 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable and motor cable.

  1. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK


11.CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A259710
  1. Remove the connector cover assembly from the inverter with converter assembly.



    A259712E01
  1. Check that the bolt for the No. 4 floor wire is tightened to the specified torque, the No. 4 floor wire is connected securely, and there are no contact problems.

    Specified Condition:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

  1. Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.

  1. Check for arc marks at the bolt and terminals for the No. 4 floor wire.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the No. 4 floor wire to the inverter with converter assembly.

  1. Install the connector cover assembly.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


12.CHECK SERVICE PLUG GRIP (CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.

    OK:
    Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.



NG
REPLACE SERVICE PLUG GRIP (Click here)
OK


13.INSPECT SERVICE PLUG GRIP
  1. Remove the service plug drip.



    A204559E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Service plug grip terminals
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Service plug grip

  1. Install the service plug drip.



NG
REPLACE SERVICE PLUG GRIP (Click here)
OK


14.CHECK NO. 4 FLOOR WIRE

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 4 hybrid battery shield panel .



    A259723E04
  1. Disconnect connectors Q2 and Q3 of the No. 4 floor wire from the hybrid battery junction block assembly.



    A259710
  1. Remove the connector cover assembly from the inverter with converter assembly.



    A259712E01
  1. Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.



    A258639E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    Q1-1 (CBI) - Q2-1 (CBI) (Positive terminal)
    Power switch off
    Below 1 Ω
    Q1-2 (CEI) - Q3-1 (CEI) (Negative terminal)
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *1
    Shield Ground
    *a
    No. 4 Floor Wire
    (Inverter with Converter Assembly Side)
    *b
    No. 4 Floor Wire
    (Hybrid Battery Junction Block Assembly Side)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    Q2-1 (CBI) - Body ground and shielded ground
    Power switch off
    10 MΩ or higher
    Q3-1 (CEI) - Body ground and shielded ground
    Power switch off
    10 MΩ or higher
    Q2-1 (CBI) - Q3-1 (CEI)
    Power switch off
    10 MΩ or higher

  1. Connect the No. 4 floor wire to the hybrid battery junction block assembly.

  1. Connect the No. 4 floor wire to the inverter with converter assembly.

  1. Install the connector cover assembly.

  1. Install the No. 4 hybrid battery shield panel.



NG
REPLACE NO. 4 FLOOR WIRE (Click here)
OK


15.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A259731E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A-1 (+) - Q2-1 (CBI)
    Auxiliary battery voltage is not applied between terminals O9-1 (SMRB) and O9-2 (GND)
    10 kΩ or higher
    A-1 (+) - Q2-1 (CBI)
    Auxiliary battery voltage is applied between terminals O9-1 (SMRB) and O9-2 (GND)
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Hybrid Battery Junction Block Assembly)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    O9-1 (SMRB) - O9-2 (GND)
    -40 to 80°C (-40 to 176°F)
    25.0 to 59.0 Ω

  1. Install the hybrid battery junction block assembly.



NG
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)
OK


16.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRG)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A259731E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    q1-1 (-) - Q3-1 (CEI)
    Auxiliary battery voltage is not applied between terminals O9-3 (SMRG) and O9-2 (GND)
    10 kΩ or higher
    q1-1 (-) - Q3-1 (CEI)
    Auxiliary battery voltage is applied between terminals O9-3 (SMRG) and O9-2 (GND)
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Hybrid Battery Junction Block Assembly)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    O9-3 (SMRG) - O9-2 (GND)
    -40 to 80°C (-40 to 176°F)
    25.0 to 59.0 Ω

  1. Install the hybrid battery junction block assembly.



NG
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)
OK


17.CHECK FUSE (INV)


    A256539E01
  1. Remove the INV fuse from the No. 2 engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    INV fuse terminal
    Always
    Below 1Ω

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block
    *2
    INV fuse

  1. Install the INV fuse.



NG
Go to step 27
OK


18.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A14 from inverter with converter assembly.



    A258451E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A14-10 (GND1) - Body ground
    Power switch off
    Below 1 Ω
    A14-11 (GND2) - Body ground
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A14-30 (+B) - Body ground
    Power switch on (IG)
    11 to 14 V
    A14-31 (+B2) - Body ground
    Power switch on (IG)
    11 to 14 V

    NOTICE:
    Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE POWER SOURCE CIRCUIT
OK


19.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A38 from the power management control ECU.

  1. Disconnect connector A14 from the inverter with converter assembly.



    A319047E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    A38-34 (HTM+) - A14-9 (HTM+)
    Power switch off
    Below 1 Ω
    A38-33 (HTM-) - A14-20 (HTM-)
    Power switch off
    Below 1 Ω
    A38-21 (MTH+) - A14-8 (MTH+)
    Power switch off
    Below 1 Ω
    A38-20 (MTH-) - A14-19 (MTH-)
    Power switch off
    Below 1 Ω
    A38-32 (REQ+) - A14-26 (REQ+)
    Power switch off
    Below 1 Ω
    A38-31 (REQ-) - A14-37 (REQ-)
    Power switch off
    Below 1 Ω
    A38-29 (CLK+) - A14-7 (CLK+)
    Power switch off
    Below 1 Ω
    A38-28 (CLK-) - A14-18 (CLK-)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A38-34 (HTM+) or A14-9 (HTM+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A38-33 (HTM-) or A14-20 (HTM-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A38-21 (MTH+) or A14-8 (MTH+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A38-20 (MTH-) or A14-19 (MTH-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A38-32 (REQ+) or A14-26 (REQ+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A38-31 (REQ-) or A14-37 (REQ-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A38-29 (CLK+) or A14-7 (CLK+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A38-28 (CLK-) or A14-18 (CLK-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A38-34 (HTM+) or A14-9 (HTM+) - Body ground
    Power switch on (IG)
    Below 1 V
    A38-33 (HTM-) or A14-20 (HTM-) - Body ground
    Power switch on (IG)
    Below 1 V
    A38-21 (MTH+) or A14-8 (MTH+) - Body ground
    Power switch on (IG)
    Below 1 V
    A38-20 (MTH-) or A14-19 (MTH-) - Body ground
    Power switch on (IG)
    Below 1 V
    A38-32 (REQ+) or A14-26 (REQ+) - Body ground
    Power switch on (IG)
    Below 1 V
    A38-31 (REQ-) or A14-37 (REQ-) - Body ground
    Power switch on (IG)
    Below 1 V
    A38-29 (CLK+) or A14-7 (CLK+) - Body ground
    Power switch on (IG)
    Below 1 V
    A38-28 (CLK-) or A14-18 (CLK-) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


20.CHECK POWER MANAGEMENT CONTROL ECU
  1. Disconnect connector A38 from the power management control ECU.



    A334209E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A38-34 (HTM+) - A38-33 (HTM-)
    Power switch off
    80 to 170 Ω
    A38-21 (MTH+) - A38-20 (MTH-)
    Power switch off
    80 to 170 Ω
    A38-32 (REQ+) - A38-31 (REQ-)
    Power switch off
    80 to 170 Ω
    A38-29 (CLK+) - A38-28 (CLK-)
    Power switch off
    80 to 170 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK


21.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A259190
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


22.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A259189
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

23.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A259190
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


24.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector E1 from the inverter with converter assembly.



    A266896E01
  1. Disconnect the generator resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    E1-1 (GRF) - E13-1 (GRF)
    Power switch off
    Below 1 Ω
    E1-7 (GRFG) - E13-5 (GRFG)
    Power switch off
    Below 1 Ω
    E1-2 (GSN) - E13-2 (GSN)
    Power switch off
    Below 1 Ω
    E1-8 (GSNG) - E13-6 (GSNG)
    Power switch off
    Below 1 Ω
    E1-3 (GCS) - E13-3 (GCS)
    Power switch off
    Below 1 Ω
    E1-9 (GCSG) - E13-7 (GCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    E1-1 (GRF) or E13-1 (GRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-7 (GRFG) or E13-5 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-2 (GSN) or E13-2 (GSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-8 (GSNG) or E13-6 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-3 (GCS) or E13-3 (GCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-9 (GCSG) or E13-7 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Front view of wire harness connector
    (to Generator Resolver)

    HINT:
    The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the generator resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

25.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A259189
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


26.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector E1 from the inverter with converter assembly.



    A266897E01
  1. Disconnect the motor resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    E1-4 (MRF) - E12-1 (MRF)
    Power switch off
    Below 1 Ω
    E1-11 (MRFG) - E12-4 (MRFG)
    Power switch off
    Below 1 Ω
    E1-5 (MSN) - E12-2 (MSN)
    Power switch off
    Below 1 Ω
    E1-12 (MSNG) - E12-5 (MSNG)
    Power switch off
    Below 1 Ω
    E1-6 (MCS) - E12-3 (MCS)
    Power switch off
    Below 1 Ω
    E1-13 (MCSG) - E12-6 (MCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    E1-4 (MRF) or E12-1 (MRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-11 (MRFG) or E12-4 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-5 (MSN) or E12-2 (MSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-12 (MSNG) or E12-5 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-6 (MCS) or E12-3 (MCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    E1-13 (MCSG) or E12-6 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Front view of wire harness connector
    (to Motor Resolver)

    HINT:
    The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the motor resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

27.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - INV FUSE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A14 from the inverter with converter assembly.



    A258451E07
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A14-30 (+B) - Body ground
    Power switch off
    10 kΩ or higher
    A14-31 (+B2) - Body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 29
OK


28.REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Click here)

NEXT

REPLACE FUSE (INV) 

29.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (INV)