Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    P0ABF-123    Hybrid Battery Pack Current Sensor Circuit

DTC    P0AC1-123    Hybrid Battery Pack Current Sensor Circuit Low

DTC    P0AC2-123    Hybrid Battery Pack Current Sensor Circuit High

for Preparation Click here


DESCRIPTION


  1. The battery current sensor, which is mounted on the positive cable side of the HV battery, detects the amperage that flows into the HV battery. The battery smart unit receives a voltage, which varies between 0 and 5 V in proportion to the amperage, at its IB terminal from the battery current sensor. An output voltage of the battery current sensor below 2.5 V indicates that the HV battery is being charged, and above 2.5 V indicates that the HV battery is being discharged. The power management control ECU determines the charging and discharging amperage of the HV battery based on the signals that are input to its IB terminal from the battery smart unit, and calculates the SOC (state of charge) of the HV battery through the accumulated amperage.


    A260083E02


DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0ABF
P0AC1
P0AC2
123
When the battery current sensor is abnormal (1 trip detection)
  1. Hybrid battery junction block assembly
  2. Battery smart unit
  3. Wire harness or connector

WIRING DIAGRAM


A255194E03

Refer to the wiring diagram for DTC U0A29-123 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    P0AFC-123 is not output.
    A
    P0AFC-123 is also output.
    B

  1. Turn the power switch off.

  1. Disconnect the intelligent tester from the DLC3.



B
GO TO DTC CHART (P0AFC-123) (Click here)
A


2.CHECK BATTERY SMART UNIT (IGCT VOLTAGE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the rear side seat back assembly LH (Click here).

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A260174E16
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    N18-3 (IGCT) - N18-6 (GND)
    Power switch on (IG)
    11 to 14 V

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Smart Unit)

NOTICE:
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

HINT:
As there might be an intermittent malfunction in the battery smart unit power source circuit, inspect the following even if the measured voltage is as specified:

  1. Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)
  2. Fuse condition (before and after removing fuse(s)) (IGCT circuit)
  3. Connection condition of connectors (IGCT circuit)
  4. Wire harness condition (IGCT circuit)
  5. Wire harness condition (GND circuit)
  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Install the rear side seat back assembly LH.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY SMART UNIT POWER SOURCE CIRCUIT)
OK


3.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BATTERY SMART UNIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 HV battery LH cover bracket .

  1. Remove the No. 4 hybrid battery shield panel .

  1. Disconnect only the z8 connector of the battery smart unit.



    A259430E01
  1. Disconnect the z9 battery current sensor connector from the hybrid battery junction block assembly.



    A260183E01
  1. Measure the resistance according to the value(s) in the tables below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    z8-5 (IB) - z9-3 (IB)
    Power switch off
    Below 1 Ω
    z8-12 (GIB) - z9-2 (GIB)
    Power switch off
    Below 1 Ω
    z8-6 (VIB) - z9-1 (VIB)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    z8-5 (IB) or z9-3 (IB) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    z8-12 (GIB) or z9-2 (GIB) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    z8-6 (VIB) or z9-1 (VIB) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Battery Smart Unit)
    *b
    Front view of wire harness connector
    (to Hybrid Battery Junction Block Assembly)

HINT:
Because the battery harness is not available as a supply part, if the harness cannot be repaired, replace the HV battery assembly.

  1. Connect the battery smart unit connector.

  1. Connect the battery current sensor connector to the hybrid battery junction block assembly.

  1. Install the No. 4 hybrid battery shield panel.

  1. Install the No. 1 HV battery LH cover bracket.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK BATTERY SMART UNIT (VIB VOLTAGE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 HV battery LH cover bracket .

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A260172E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    z8-6 (VIB) - z8-12 (GIB)
    Power switch on (IG)
    4.6 to 5.4 V

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Smart Unit)

NOTICE:
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Install the No. 1 HV battery LH cover bracket.



NG
REPLACE BATTERY SMART UNIT (Click here)
OK


5.CHECK BATTERY SMART UNIT (IB VOLTAGE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 HV battery LH cover bracket .

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A260172E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    z8-5 (IB) - z8-12 (GIB)
    Power switch on (IG)
    2.46 to 2.54 V

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Smart Unit)

NOTICE:
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Install the No. 1 HV battery LH cover bracket.



NG
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPLACE BATTERY SMART UNIT (Click here)