Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    P0AC0-123    Hybrid Battery Pack Current Sensor Circuit Range / Performance

for Preparation Click here


DESCRIPTION

Refer to the Description for DTC P0ABF-123 .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0AC0
123
When the battery current sensor is abnormal (1 or 2 trip detection)
  1. Hybrid battery junction block assembly
  2. Battery smart unit

INSPECTION PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check and record any HV system DTCs, INF codes and freeze frame data.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    Only DTC P0AC0-123 is output or DTC P0AC0-123 and DTCs other than those in the following table are output.
    A
    Any of the DTCs in the following table are output at the same time.
    B

    Relevant DTC
    P0A95-123
    High Voltage Fuse
    P0ABF-123
    Hybrid Battery Pack Current Sensor Circuit
    P0AC1-123
    Hybrid Battery Pack Current Sensor Circuit Low
    P0AC2-123
    Hybrid Battery Pack Current Sensor Circuit High
    P0AFC-123
    Hybrid Battery Pack Sensor Module
    P0B3D-123, P0B42-123, P0B47-123, P0B4C-123, P0B51-123, P0B56-123, P0B5B-123, P0B60-123, P0B65-123, P0B6A-123, P0B6F-123, P0B74-123, P0B79-123, P0B7E-123, P0B83-123, P0B88-123, P0B8D-123, P0B92-123
    Hybrid Battery Voltage Sensor "A - R" Circuit Low

  1. Turn the power switch off.

  1. Disconnect the intelligent tester from the DLC3.



B
GO TO DTC CHART (HYBRID BATTERY SYSTEM) (Click here)
A


2.READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    Do not turn the power switch on (READY).

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / Battery Block Vol -V01 to V17.

    NOTICE:
    Select "Battery Block Vol -V01 to V17" only. (Do not select any other Data List items.)



  1. Check the voltage of each "Battery Block Vol" of "Battery Block Vol -V01 to V17" in the Data List with the power switch on (IG).


    A315508E03

    Specified Condition:
    Any "Battery Block Vol" changes by 0.3 V or more, 60 seconds after the power switch is turned on (IG). (The difference between the maximum and minimum voltage is 0.3 V or more.)

    Result:
    Result
    Proceed to
    The change in voltage of any "Battery Block Vol" is 0.3 V or more.
    A
    Other than above.
    B

  1. Turn the power switch off.

  1. Disconnect the intelligent tester from the DLC3.



B
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)
A

REPLACE BATTERY SMART UNIT (Click here)