DTC P0AE2-773 Hybrid Battery Precharge Contactor Circuit Stuck Closed |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0AE2 | 773 | SMRP on the HV battery positive side stuck closed |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0E2-773 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 658, 791 | Generator Control Module |
| P0A1B-786, 794 | Drive Motor "A" Control Module |
| P0A1D-148 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0AA4-232 | Hybrid Battery Negative Contactor Circuit Stuck Closed |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0AE7-224 | Hybrid Battery Precharge Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P2511-149 | HV CPU Power Relay Sense Circuit Intermittent No Continuity |
| P3004-132 | Power Cable Malfunction |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK FREEZE FRAME DATA (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data of DTC P0AE2-773.
| Result | Proceed to |
| "VL-Voltage before Boosting" is 55 V or more. | A |
| "VL-Voltage before Boosting" is less than 55 V. | B |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR) |
![]() |
Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors (Click here).
|
| ||||
|
| ||||
| 4.CONNECT SECURELY |
| NEXT | |
| 5.CHECK CONNECTOR CONNECTION CONDITION (NO. 2 FLOOR WIRE CONNECTOR) |
Check the connector connections and contact pressure of the relevant terminals for the IO2 floor wire connector (Click here).
|
| ||||
|
| ||||
| 6.CONNECT SECURELY |
| NEXT | |
| 7.CHECK CONNECTOR CONNECTION CONDITION (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Remove the No. 4 hybrid battery shield panel .
![]() |
Check the connector connections and contact pressure of the relevant terminals for the hybrid battery junction block assembly connector (Click here).
Install the No. 4 hybrid battery shield panel.
|
| ||||
|
| ||||
| 8.CONNECT SECURELY |
| NEXT | |
| 9.CHECK GROUND WIRE CONNECTION CONDITION (SMR ACTIVATION LOW-VOLTAGE CIRCUIT) |
Check the installation condition of the ground wires I1, I2 and O1.
|
| ||||
|
| ||||
| 10.CONNECT SECURELY |
| NEXT | |
| 11.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY) |
Check that the service plug grip is not installed.
Remove the No. 4 hybrid battery shield panel .
Disconnect the O9 hybrid battery junction block assembly connector.
Disconnect the I3 power management control ECU connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I3-3 (SMRP) - O9-4 (SMRP) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| I3-3 (SMRP) and O9-4 (SMRP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
| *b | Rear view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Reconnect the I3 power management control ECU connector.
Reconnect the O9 hybrid battery junction block assembly connector.
Install the No. 4 hybrid battery shield panel.
|
| ||||
|
| ||||
| 12.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | |
| 13.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BODY GROUND) |
Check that the service plug grip is not installed.
Remove the No. 4 hybrid battery shield panel .
Disconnect the O9 hybrid battery junction block assembly connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O9-2 (GND) - Body ground | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Reconnect the O9 hybrid battery junction block assembly connector.
Install the No. 4 hybrid battery shield panel.
|
| ||||
|
| ||||
| 14.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | |
| 15.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP) |
Check that the service plug grip is not installed.
Remove the No. 4 hybrid battery shield panel .
Disconnect the O9 hybrid battery junction block assembly connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O9-4 (SMRP) - O9-2 (GND) | -40 to 80 °C (-40 to 176°F) | 112 to 274 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Reconnect the O9 hybrid battery junction block assembly connector.
Install the No. 4 hybrid battery shield panel.
|
| ||||
|
| ||||
| 16.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY |
|
| ||||
| 17.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid battery shield sub-assembly .
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| Q3-1 (CEI) - q1-1 (-) | Power switch off | 10 kΩ or higher |
Install the No. 1 hybrid battery shield sub-assembly.
| NEXT | |
| 18.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY |
| NEXT | |
| 19.CHECK POWER MANAGEMENT CONTROL ECU (CHECK FOR NORMAL OPERATION) |
Install the service plug grip.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Clear the DTCs (Click here).
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Data List / Power Resource VB, VL-Voltage before Boosting.
According to the display on the intelligent tester, read the Data List and monitor the values of "Power Resource VB" and "VL-Voltage before Boosting" for 3 minutes.
| Result | Proceed to |
| Difference between "Power Resource VB" and "VL-Voltage before Boosting" is always less than 100 V. | A |
| Difference between "Power Resource VB" and "VL-Voltage before Boosting" is 100 V or more. | B |
Turn the power switch off.
|
| ||||
| A | ||
| ||