WATER PUMP WITH MOTOR > REMOVAL |
| 1. DRAIN COOLANT (for Inverter) |
Remove the reserve tank cap.
![]() |
Using a hexagon wrench (10 mm), remove the drain plug indicated in the illustration and drain the coolant.
Install the plug with a new gasket.
| 2. REMOVE INVERTER RESERVE TANK ASSEMBLY |
![]() |
Remove the 2 bolts and inverter reserve tank assembly.
| 3. REMOVE WATER PUMP WITH MOTOR ASSEMBLY |
![]() |
Disconnect the water hose.
![]() |
Disconnect the connector.
Remove the 3 bolts.
![]() |
Disconnect the water hose.