DTC P0A9D-123 Hybrid Battery Temperature Sensor "A" Circuit Low |
DTC P0A9E-123 Hybrid Battery Temperature Sensor "A" Circuit High |
DTC P0AC7-123 Hybrid Battery Temperature Sensor "B" Circuit Low |
DTC P0AC8-123 Hybrid Battery Temperature Sensor "B" Circuit High |
DTC P0ACC-123 Hybrid Battery Temperature Sensor "C" Circuit Low |
DTC P0ACD-123 Hybrid Battery Temperature Sensor "C" Circuit High |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A9D P0A9E P0AC7 P0AC8 P0ACC P0ACD | 123 | When the temperature of the battery temperature sensor is less than the standard value (open) or higher than the standard value (shorted) (1 trip detection). |
|
| Temperature Displayed | Malfunction |
| Below -45°C (-49°F) | Open or +B short circuit |
| 95°C (203°F) or more | GND short circuit |
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read output DTCs (Click here).
| Result | Proceed to |
| P0AFC-123 is not output. | A |
| P0AFC-123 is also output. | B |
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
|
| ||||
| A | |
| 2.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Temp of Batt TB 1 to 3.
Turn the power switch off.
| NEXT | |
| 3.CHECK CONNECTOR CONNECTION CONDITION |
Check that the service plug grip is not installed.
Remove the No. 1 HV battery LH cover bracket .
![]() |
Check the connections of the z8 battery smart unit connector.
Install the No. 1 HV battery LH cover bracket.
|
| ||||
| OK | |
| 4.CHECK HV BATTERY (BATTERY TEMPERATURE SENSOR) |
Check that the service plug grip is not installed.
Remove the No. 1 HV battery LH cover bracket .
Disconnect connectors z8 and N18 from the battery smart unit.
![]() |
Measure the resistance of the circuit for the malfunctioning sensor (battery temperature sensor 0 to 2).
| Tester Connection | Battery Temperature Sensor No. |
| z8-4 (TBO) - z8-10 (GBO) | 0 |
| z8-3 (TB1) - z8-9 (GB1) | 1 |
| z8-2 (TB2) - z8-8 (GB2) | 2 |
| Thermistor Temperature | Switch Condition | Specified Condition |
| 0°C (32°F) | Power switch off | 26.7 to 27.8 kΩ |
| 25°C (77°F) | Power switch off | 9.9 to 10.1 kΩ |
| 40°C (104°F) | Power switch off | 5.73 to 5.92 kΩ |
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| z8-4 (TBO) - N18-3 (IGCT) | Power switch off | 10 kΩ or higher |
| z8-4 (TBO) - N18-6 (GND) | Power switch off | 10 kΩ or higher |
| z8-10 (GBO) - N18-3 (IGCT) | Power switch off | 10 kΩ or higher |
| z8-10 (GBO) - N18-6 (GND) | Power switch off | 10 kΩ or higher |
| z8-3 (TB1) - N18-3 (IGCT) | Power switch off | 10 kΩ or higher |
| z8-3 (TB1) - N18-6 (GND) | Power switch off | 10 kΩ or higher |
| z8-9 (GB1) - N18-3 (IGCT) | Power switch off | 10 kΩ or higher |
| z8-9 (GB1) - N18-6 (GND) | Power switch off | 10 kΩ or higher |
| z8-2 (TB2) - N18-3 (IGCT) | Power switch off | 10 kΩ or higher |
| z8-2 (TB2) - N18-6 (GND) | Power switch off | 10 kΩ or higher |
| z8-8 (GB2) - N18-3 (IGCT) | Power switch off | 10 kΩ or higher |
| z8-8 (GB2) - N18-6 (GND) | Power switch off | 10 kΩ or higher |
| z8-1 (TCO) - N18-3 (IGCT) | Power switch off | 10 kΩ or higher |
| z8-1 (TCO) - N18-6 (GND) | Power switch off | 10 kΩ or higher |
| z8-7 (GCO) - N18-3 (IGCT) | Power switch off | 10 kΩ or higher |
| z8-7 (GCO) - N18-6 (GND) | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
Connect the battery smart unit connectors.
Install the No. 1 HV battery LH cover bracket.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (BATTERY TEMPERATURE SENSOR) |
Check that the service plug grip is not installed.
Remove the No. 1 HV battery LH cover bracket .
Check the wire harness and connectors of the battery temperature sensor for abnormalities by sight and touch.
Install the No. 1 HV battery LH cover bracket.
|
| ||||
| OK | ||
| ||