DTC P0A10-263 DC / DC Converter Status Circuit High Input |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A10 | 263 | Short to +B in the hybrid vehicle converter (DC/DC converter) NODD signal line |
|
| 1.CHECK POWER MANAGEMENT CONTROL ECU (NODD) |
Turn the power switch on (READY).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-23 (NODD) - I3-6 (E1) | Power switch on (READY) | 5 to 7 V |
| *a | Component with harness connected (Power Management Control ECU) |
Turn the power switch off.
|
| ||||
| OK | |
| 2.CLEAR DTC |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Clear DTCs and freeze frame data.
Turn the power switch off.
| NEXT | |
| 3.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A10-263 is not output. | A |
| P0A10-263 is output again. | B |
Turn the power switch off.
|
| ||||
| A | |
| 4.CHECK FOR INTERMITTENT PROBLEMS |
|
| ||||
| OK | ||
| ||
| 5.CHECK POWER MANAGEMENT CONTROL ECU (NODD) |
Check that the service plug grip is not installed.
Disconnect connector A13 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A13-5 (NODD) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU) |
Check that the service plug grip is not installed.
Disconnect connector A13 from the inverter with converter assembly.
Disconnect connector A38 from the power management control ECU.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A13-5 (NODD) or A38-23 (NODD) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector (to Power Management Control ECU) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
|
| ||||
| OK | ||
| ||