DTC P0A7A-518 Generator Inverter Performance |
DTC P0A7A-811 Generator Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A7A | 518 | Generator inverter fail signal detection (overcurrent due to hybrid vehicle transaxle assembly malfunction) |
|
| 811 | Abnormal generator current value detection (hybrid vehicle transaxle assembly malfunction) |
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A7A-203 is not output. | A |
| P0A7A-203 is also output. | B |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A7A-518 or 811 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-585, 587, 589, 590 | DC/DC Converter Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72-333 | Generator Phase V Current |
| P0A75-341 | Generator Phase W Current |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-585, 587, 589, 590 | DC/DC Converter Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-7 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-2 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-3 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 5.CHECK GENERATOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - E1-7 (GRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-2 (GSN) - E1-8 (GSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-3 (GCS) - E1-9 (GCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) or E1-7 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E1-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E1-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-11 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-5 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-12 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-13 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 7.CHECK MOTOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - E1-11 (MRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-5 (MSN) - E1-12 (MSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-6 (MCS) - E1-13 (MCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) or E1-11 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E1-12 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E1-13 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 8.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 9.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 10.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 11.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - E13-1 (GRF) | Power switch off | Below 1 Ω |
| E1-7 (GRFG) - E13-5 (GRFG) | Power switch off | Below 1 Ω |
| E1-2 (GSN) - E13-2 (GSN) | Power switch off | Below 1 Ω |
| E1-8 (GSNG) - E13-6 (GSNG) | Power switch off | Below 1 Ω |
| E1-3 (GCS) - E13-3 (GCS) | Power switch off | Below 1 Ω |
| E1-9 (GCSG) - E13-7 (GCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) or E13-1 (GRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-7 (GRFG) or E13-5 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E13-2 (GSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-8 (GSNG) or E13-6 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E13-3 (GCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-9 (GCSG) or E13-7 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 12.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 13.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - E12-1 (MRF) | Power switch off | Below 1 Ω |
| E1-11 (MRFG) - E12-4 (MRFG) | Power switch off | Below 1 Ω |
| E1-5 (MSN) - E12-2 (MSN) | Power switch off | Below 1 Ω |
| E1-12 (MSNG) - E12-5 (MSNG) | Power switch off | Below 1 Ω |
| E1-6 (MCS) - E12-3 (MCS) | Power switch off | Below 1 Ω |
| E1-13 (MCSG) - E12-6 (MCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) or E12-1 (MRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-11 (MRFG) or E12-4 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E12-2 (MSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-12 (MSNG) or E12-5 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E12-3 (MCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-13 (MCSG) or E12-6 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||