DTC P0A40-504 Drive Motor "A" Position Sensor Circuit Range / Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A40 | 504 | Motor inverter overvoltage signal detection (overvoltage due to hybrid vehicle transaxle assembly malfunction) |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A40-504 only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit / Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit / Open |
| P06E6-164 | Sensor Power Supply "C" Circuit / Open |
| P0A1A-151, 166, 517, 658, 791, 809 | Generator Control Module |
| P0A1B-198, 505, 554, 786, 794, 806 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500, 506, 556, 808 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513, 518, 811 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-287, 555, 807 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 810 | Generator Inverter Performance |
| P0A93-346 | Inverter Cooling System Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range / Performance |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range / Performance |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0D2E-565, 586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range / Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range / Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range / Performance |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range / Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range / Performance |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range / Performance |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range / Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range / Performance |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range / Performance |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range / Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range / Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range / Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit / Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3004-803 | High Voltage Power Resource |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P314A-828 | Inverter Coolant Pump Speed Signal |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-7 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-2 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-3 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 4.CHECK GENERATOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - E1-7 (GRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-2 (GSN) - E1-8 (GSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-3 (GCS) - E1-9 (GCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) or E1-7 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E1-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E1-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-11 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-5 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-12 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-13 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 6.CHECK MOTOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - E1-11 (MRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-5 (MSN) - E1-12 (MSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-6 (MCS) - E1-13 (MCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) or E1-11 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E1-12 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E1-13 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 7.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 8.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 9.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) - E13-1 (GRF) | Power switch off | Below 1 Ω |
| E1-7 (GRFG) - E13-5 (GRFG) | Power switch off | Below 1 Ω |
| E1-2 (GSN) - E13-2 (GSN) | Power switch off | Below 1 Ω |
| E1-8 (GSNG) - E13-6 (GSNG) | Power switch off | Below 1 Ω |
| E1-3 (GCS) - E13-3 (GCS) | Power switch off | Below 1 Ω |
| E1-9 (GCSG) - E13-7 (GCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-1 (GRF) or E13-1 (GRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-7 (GRFG) or E13-5 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E13-2 (GSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-8 (GSNG) or E13-6 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E13-3 (GCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-9 (GCSG) or E13-7 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 11.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 12.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector E1 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) - E12-1 (MRF) | Power switch off | Below 1 Ω |
| E1-11 (MRFG) - E12-4 (MRFG) | Power switch off | Below 1 Ω |
| E1-5 (MSN) - E12-2 (MSN) | Power switch off | Below 1 Ω |
| E1-12 (MSNG) - E12-5 (MSNG) | Power switch off | Below 1 Ω |
| E1-6 (MCS) - E12-3 (MCS) | Power switch off | Below 1 Ω |
| E1-13 (MCSG) - E12-6 (MCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| E1-4 (MRF) or E12-1 (MRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-11 (MRFG) or E12-4 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E12-2 (MSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-12 (MSNG) or E12-5 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E12-3 (MCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-13 (MCSG) or E12-6 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||