Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    U0110-160    Lost Communication with Drive Motor Control Module "A"

for Preparation Click here


DESCRIPTION

For a description of the inverter .
The MG ECU located in the inverter with converter assembly controls MG2 based on commands from the power management control ECU. The MG ECU monitors communication data and detects malfunctions.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
U0110
160
Error in signal transmission to the inverter with converter assembly (MG ECU) via serial communication (no transmission, out of communication standard)
  1. Wire harness or connector
  2. Inverter with converter assembly
  3. Hybrid vehicle transaxle assembly
  4. Power management control ECU

WIRING DIAGRAM

Refer to the wiring diagram for DTC U0110-159 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
  1. After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).
  2. If the DTC U0110-160 was set due to incomplete engagement of the connectors, and if the system returns to normal when the power switch is on (IG) after clearing the DTCs, DTC P324E-788 will be set. Proceed to troubleshooting without considering DTC P324E-788.

1.CLEAR DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Clear DTCs and freeze frame data.

  1. Turn the power switch off.


NEXT


2.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    DTC U0110-160 is output.
    A
    DTC U0110-160 is not output.
    B

  1. Turn the power switch off.



B
CHECK FOR INTERMITTENT PROBLEMS (Click here)
A


3.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258951
  1. Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.



    A258953
  1. Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

    Specified Condition:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

  1. Disconnect the generator cable from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the generator cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the generator cable to the inverter with converter assembly.

  1. Install the upper inverter cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


4.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258952
  1. Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258954
  1. Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

    Specified Condition:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

  1. Disconnect the motor cable from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the motor cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable to the inverter with converter assembly.

  1. Install the upper inverter cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


5.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258636
  1. Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258637E05
  1. Disconnect the generator cable and motor cable from the inverter with converter assembly.
    Text in Illustration 
    *1
    Generator Cable
    *2
    Motor Cable



    A258955E05
  1. Check MG1 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      o1-1 (W) - o1-3 (U)
      Power switch off
      59.1 to 67.5 mΩ
      o1-2 (V) - o1-1 (W)
      Power switch off
      59.1 to 67.5 mΩ
      o1-3 (U) - o1-2 (V)
      Power switch off
      62.1 to 70.5 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Generator Cable
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    o1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    o1-2 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    o1-3 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable and motor cable.

  1. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK


6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258636
  1. Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258637E05
  1. Disconnect the generator cable and motor cable from the inverter with converter assembly.
    Text in Illustration 
    *1
    Generator Cable
    *2
    Motor Cable



    A258955E06
  1. Check MG2 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      n1-1 (W) - n1-3 (U)
      Power switch off
      71.4 to 81.0 mΩ
      n1-2 (V) - n1-1 (W)
      Power switch off
      71.4 to 81.0 mΩ
      n1-3 (U) - n1-2 (V)
      Power switch off
      74.4 to 84.1 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Motor Cable
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    n1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    n1-2 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    n1-3 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable and motor cable.

  1. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK


7.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
  1. Connect an oscilloscope between the power management control ECU terminals specified in the following table.

  1. Turn the power switch on (IG).



    A204498E20
  1. Measure the waveform.
    Item
    Contents
    Tester Connection
    CH1: A39-24 (HTM+) - I3-6 (E1)
    CH2: A39-25 (HTM-) - I3-6 (E1)
    Equipment Setting
    1V/DIV., 200μs/DIV.
    Condition
    Power switch on (IG)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

    HINT:
    1. Inspect with the connector connected.
    2. If pulses are generated, the shape of the waveform can be assumed to be normal.
    3. The shape of the waveform may vary according to communication conditions.

  1. Turn the power switch off.



B
Go to step 14
A


8.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
  1. Connect an oscilloscope between the power management control ECU terminals specified in the following table.

  1. Turn the power switch on (IG).



    A204496E11
  1. Measure the waveform.
    Item
    Contents
    Tester Connection
    CH1: A39-21 (CLK+) - I3-6 (E1)
    CH2: A39-20 (CLK-) - I3-6 (E1)
    Equipment Setting
    1V/DIV., 1μs/DIV.
    Condition
    Power switch on (IG)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

    HINT:
    1. Inspect with the connector connected.
    2. If pulses are generated, the shape of the waveform can be assumed to be normal.
    3. The shape of the waveform may vary according to communication conditions.

  1. Turn the power switch off.



B
Go to step 10
A


9.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
  1. Connect an oscilloscope between the power management control ECU terminals specified in the following table.

  1. Turn the power switch on (IG).



    A204500E12
  1. Measure the waveform.
    Item
    Contents
    Tester Connection
    CH1: A39-33 (REQ+) - I3-6 (E1)
    CH2: A39-32 (REQ-) - I3-6 (E1)
    Equipment Setting
    1V/DIV., 1ms/DIV.
    Condition
    Power switch on (IG)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

    HINT:
    1. Inspect with the connector connected.
    2. If pulses are generated, the shape of the waveform can be assumed to be normal.
    3. The shape of the waveform may vary according to communication conditions.

  1. Turn the power switch off.



B
Go to step 12
A

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

10.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A39 from the power management control ECU.

  1. Disconnect connector A14 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A259928E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-21 (CLK+) - Body ground
    Power switch on (IG)
    Below 1 V
    A39-20 (CLK-) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-21 (CLK+) - A14-7 (CLK+)
    Power switch off
    Below 1 Ω
    A39-20 (CLK-) - A14-18 (CLK-)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-21 (CLK+) or A14-7 (CLK+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A39-20 (CLK-) or A14-18 (CLK-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


11.CHECK INVERTER WITH CONVERTER ASSEMBLY
  1. Disconnect connector A39 from the power management control ECU.



    A204444E30
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-21 (CLK+) - A39-20 (CLK-)
    Power switch off
    80 to 170 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

12.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A39 from the power management control ECU.

  1. Disconnect connector A14 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A259928E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-33 (REQ+) - Body ground
    Power switch on (IG)
    Below 1 V
    A39-32 (REQ-) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-33 (REQ+) - A14-26 (REQ+)
    Power switch off
    Below 1 Ω
    A39-32 (REQ-) - A14-37 (REQ-)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-33 (REQ+) or A14-26 (REQ+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A39-32 (REQ-) or A14-37 (REQ-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


13.CHECK INVERTER WITH CONVERTER ASSEMBLY
  1. Disconnect connector A39 from the power management control ECU.



    A204444E31
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-33 (REQ+) - A39-32 (REQ-)
    Power switch off
    80 to 170 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

14.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A39 from the power management control ECU.

  1. Disconnect connector A14 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A259928E04
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-24 (HTM+) - Body ground
    Power switch on (IG)
    Below 1 V
    A39-25 (HTM-) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the connector of the power management control ECU and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-24 (HTM+) - A14-9 (HTM+)
    Power switch off
    Below 1 Ω
    A39-25 (HTM-) - A14-20 (HTM-)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-24 (HTM+) or A14-9 (HTM+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A39-25 (HTM-) or A14-20 (HTM-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


15.CHECK INVERTER WITH CONVERTER ASSEMBLY
  1. Disconnect connector A39 from the power management control ECU.



    A204444E32
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-24 (HTM+) - A39-25 (HTM-)
    Power switch off
    80 to 170 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)