DTC C1442/44 Invalid Data Received from Acceleration Sensor |
DTC C1443/34 Invalid Data Received from Yaw Rate Sensor |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| C1442/44 | 572 | With terminal IG1 voltage between 9.5 and 17.4 V, an invalid data signal is received from the acceleration sensor for 10 seconds or more. |
|
| C1443/34 | 715 | With terminal IG1 voltage between 9.5 and 17.4 V, an invalid data signal is received from the yaw rate sensor for 10 seconds or more. |
|
| 1.CHECK DTC |
Clear the DTCs (Click here).
Check if the same DTC is output (Click here).
| Result | Proceed to |
| DTCs C1442/44 and C1443/34 are not output. | A |
| DTCs C1442/44 and/or C1443/34 are output (for separate type yaw rate sensor). | B |
| DTCs C1442/44 and/or C1443/34 are output (for built-in type yaw rate sensor). | C |
|
| ||||
|
| ||||
| A | ||
| ||