Home › General › SPECIFICATIONS › 2AR-FXE COOLING

2AR-FXE COOLING > SERVICE DATA



THERMOSTAT 
Condition
Specified Condition
Standard valve opening temperature
80 to 84°C (176 to 183°F)
Standard valve lift
10 to 11.3 mm (0.394 to 0.445 in.) at 95°C (203°F)

COOLING FAN MOTOR 
Item
Condition
Specified Condition
Cooling fan motor
Auxiliary battery voltage applied at 20°C (68°F)
10.6 to 16.6 A
No. 2 cooling fan motor
Auxiliary battery voltage applied at 20°C (68°F)
10.6 to 16.6 A

COOLING FAN RELAY 
Item
Tester Connection
Specified Condition
Cooling fan relay
3 - 5
10 kΩor higher
(Battery voltage is not applied between terminals 1 and 2)
3 - 5
Below 1 Ω
(Battery voltage is applied between terminals 1 and 2)

RADIATOR 
Item
Condition
Specified Condition
Radiator cap
Standard value (for brand-new cap)
93.3 to 122.7 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18.0 psi)
Minimum standard value (for used cap)
78.5 kPa (0.8 kgf/cm2, 11.4 psi)