Home › General › SPECIFICATIONS › HYBRID / BATTERY CONTROL

HYBRID / BATTERY CONTROL > SERVICE DATA



Reserve Tank Cap (for Inverter) 
Item
Specified Condition
Standard value (for brand-new cap)
94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17.7 psi)
Minimum standard value (for used cap)
94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay 
Item
Tester Connection
Specified Condition
IGCT relay
Resistance
3 - 5
10 kΩ or higher
(Auxiliary battery voltage is not applied across terminals 1 and 2)
3 - 5
Below 1 Ω
(Auxiliary battery voltage is applied across terminals 1 and 2)
INV W/ PMP relay
Resistance
3 - 5
10 kΩ or higher
(Auxiliary battery voltage is not applied across terminals 1 and 2)
3 - 5
Below 1 Ω
(Auxiliary battery voltage is applied across terminals 1 and 2)

Hybrid Battery Junction Block 
SMRB
Resistance
A-1 (+) - Q2-1 (CBI)
10 kΩ or more
(Auxiliary battery voltage is not applied between terminals 09-1 (SMRB) and 09-2 (GND))
A-1 (+) - Q2-1 (CBI)
Below 1 Ω
(Auxiliary battery voltage is applied between terminals 09-1 (SMRB) and 09-2(GND))
09-1 (SMRB) - 09-2 (GND)
25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRG
Resistance
q1-1(-) - Q3- 1(CEI)
10 kΩ or more
(Auxiliary battery voltage is not applied between terminals 09- 3(SMRG) and 09-2(GND))
q1-1(-) - Q3- 1(CEI)
Below 1 Ω
(Auxiliary battery voltage is applied between terminals 09-3(SMRG) and 09-2(GND))
09-3(SMRG) - 09-2(GND)
25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRP
Resistance
q1-1(-) - Q3- 1(CEI)
10 kΩ or more
(Auxiliary battery voltage is not applied between terminals 09- 4(SMRP) and 09-2(GND))
q1-1(-) - Q3- 1(CEI)
28.5 to 31.5 Ω
(Auxiliary battery voltage is applied between terminals 09-4(SMRP) and 09-2(GND))
09-4(SMRP) and 09-2(GND)
112 to 274 Ω at -40 to 80°C (-40 to 176°F)

Combination Switch Assembly 
Pattern select switch assembly
Resistance
L128-4 (S) - L128-1 (E)
Below 1 Ω
(Pattern select switch assembly operated)
L128-4 (S) - L128-1 (E)
10 kΩ or more
(Pattern select switch assembly operated)

Service Plug Grip 
Service plug grip
-
Below 1 Ω