HYBRID / BATTERY CONTROL > SERVICE DATA |
| Item | Specified Condition |
| Standard value (for brand-new cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17.7 psi) |
| Minimum standard value (for used cap) | 94 kPa (1.0 kgf/cm2, 13.6 psi) |
| Item | Tester Connection | Specified Condition |
| IGCT relay Resistance | 3 - 5 | 10 kΩ or higher (Auxiliary battery voltage is not applied across terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (Auxiliary battery voltage is applied across terminals 1 and 2) | |
| INV W/ PMP relay Resistance | 3 - 5 | 10 kΩ or higher (Auxiliary battery voltage is not applied across terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (Auxiliary battery voltage is applied across terminals 1 and 2) |
| SMRB Resistance | A-1 (+) - Q2-1 (CBI) | 10 kΩ or more (Auxiliary battery voltage is not applied between terminals 09-1 (SMRB) and 09-2 (GND)) |
| A-1 (+) - Q2-1 (CBI) | Below 1 Ω (Auxiliary battery voltage is applied between terminals 09-1 (SMRB) and 09-2(GND)) | |
| 09-1 (SMRB) - 09-2 (GND) | 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRG Resistance | q1-1(-) - Q3- 1(CEI) | 10 kΩ or more (Auxiliary battery voltage is not applied between terminals 09- 3(SMRG) and 09-2(GND)) |
| q1-1(-) - Q3- 1(CEI) | Below 1 Ω (Auxiliary battery voltage is applied between terminals 09-3(SMRG) and 09-2(GND)) | |
| 09-3(SMRG) - 09-2(GND) | 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRP Resistance | q1-1(-) - Q3- 1(CEI) | 10 kΩ or more (Auxiliary battery voltage is not applied between terminals 09- 4(SMRP) and 09-2(GND)) |
| q1-1(-) - Q3- 1(CEI) | 28.5 to 31.5 Ω (Auxiliary battery voltage is applied between terminals 09-4(SMRP) and 09-2(GND)) | |
| 09-4(SMRP) and 09-2(GND) | 112 to 274 Ω at -40 to 80°C (-40 to 176°F) |
| Pattern select switch assembly Resistance | L128-4 (S) - L128-1 (E) | Below 1 Ω (Pattern select switch assembly operated) |
| L128-4 (S) - L128-1 (E) | 10 kΩ or more (Pattern select switch assembly operated) |
| Service plug grip | - | Below 1 Ω |