REFRIGERANT LINE > INSTALLATION |
| 1. INSTALL PIPING CLAMP |
Remove the vinyl tape from the open ends of the suction pipe sub-assembly and suction hose sub-assembly.
![]() |
Install a new piping clamp onto the suction hose sub-assembly.
| *1 | Piping Clamp |
| *2 | Groove |
| *3 | Suction Hose Sub-assembly |
Thoroughly coat 2 new O-rings and the contact surface of the suction hose sub-assembly with compressor oil (ND-OIL11).
Install the 2 O-rings onto the suction hose sub-assembly.
![]() |
Engage the suction tube sub-assembly and suction hose sub-assembly by matching the alignment marks.
| *a | Large Diameter Section of Piping Clamp |
| *b | Alignment Mark |
![]() |
Securely insert the piping clamp to the point where the large diameter section of the piping clamp is covered by the suction pipe sub-assembly.
| *a | Large Diameter Section of Piping Clamp |