HYBRID CONTROL SYSTEM > TERMINALS OF ECU |

| *1 | Power Management Control ECU | - | - |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| A38-2 (+B2) - I3-6 (E1) | B - BR | Power source | Power switch on (IG) | 11 to 14 V |
| A38-11 (VLO) - I3-6 (E1) | BE - BR | DC/DC operation monitor / voltage change signal | Power switch on (IG) | Pulse generation (Waveform 1) |
| A38-13 (IWP) - I3-6 (E1) | LG - BR | Inverter water pump assembly signal | Power switch on (READY) | Pulse generation (Waveform 2) |
| A38-14 (NIWP) - I3-6 (E1) | R - BR | Inverter water pump assembly signal | Power switch on (READY) | Pulse generation (Waveform 2) |
| A38-15 (BL) - I3-6 (E1) | W - BR | Back up light | Power switch on (IG), shift lever in R | 11 to 14 V |
| A38-16 (GI) - I3-6 (E1) | B - BR | Camshaft position sensor signal | Power switch on (READY), with engine running | Pulse generation (Waveform 3) |
| A38-19 (CLK) - I3-6 (E1) | GR - BR | A/C communication signal | Power switch on (READY), air conditioning system stopped | Pulse generation (Waveform 4) |
| A38-20 (STB) - I3-6 (E1) | V - BR | A/C communication signal | Power switch on (READY), air conditioning system stopped | Pulse generation (Waveform 4) |
| A38-21 (NODD) - I3-6 (E1) | SB - BR | DC/DC operation | DC/DC converter operating normally | 5 to 7 V |
| DC/DC converter not operating normally | 2 to 4 V | |||
| DC/DC converter operating prohibited | 0.1 to 0.5 V | |||
| A38-24 (MMT) - A38-25 (MMTG) | G - GR | Motor temperature sensor | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | |||
| A38-26 (GMT) - A38-27 (GMTG) | L - P | Generator temperature sensor | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | |||
| A38-29 (SI0) - I3-6 (E1) | P - BR | HV battery blower fan operation signal | Power switch on (IG), during Active Test | Pulse generation (Waveform 5) |
| A38-30 (ETI) - I3-6 (E1) | Y - BR | A/C communication signal | Power switch on (READY), air conditioning system stopped | Pulse generation (Waveform 4) |
| A38-31 (ITE) - I3-6 (E1) | W - BR | A/C communication signal | Power switch on (READY), air conditioning system stopped | Pulse generation (Waveform 4) |
| A38-32 (ILK) - I3-6 (E1) | L - BR | Interlock switch | Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) and service plug grip installed correctly | 0 to 1.5 V |
| Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) or service plug grip not installed | 11 to 14 V | |||
| A39-1 (IG2) - I3-6 (E1) | BE - BR | Power source | Power switch on (IG) | 11 to 14 V |
| A39-2 (IG2D) - I3-6 (E1) | R - BR | IG2 relay | Power switch on (IG) | 11 to 14 V |
| A39-5 (+B1) - I3-6 (E1) | B - BR | Power source | Power switch on (IG) | 11 to 14 V |
| A39-6 (MREL) - I3-6 (E1) | V - BR | Main relay | Power switch on (IG) | 11 to 14 V |
| A39-7 (ST1-) - I3-6 (E1) | GR - BR | Brake cancel switch | Power switch on (IG), brake pedal depressed | 0 to 1.5 V |
| Power switch on (IG), brake pedal released | 11 to 14 V | |||
| A39-8 (FD) - I3-6 (E1) | LG - BR | Shift lever position signal | Power switch on (IG), shift lever in D or B | 11 to 14 V |
| Power switch on (IG), shift lever not in D or B | 0.5 to 1.5 V | |||
| A39-9 (RV) - I3-6 (E1) | P - BR | Shift lever position signal | Power switch on (IG), shift lever in R | 11 to 14 V |
| Power switch on (IG), shift lever not in R | 0.5 to 1.5 V | |||
| A39-11 (D) - I3-6 (E1) | Y - BR | Shift lever position signal | Power switch on (IG), shift lever in D | 11 to 14 V |
| Power switch on (IG), shift lever not in D | 0.5 to 1.5 V | |||
| A39-12 (N) - I3-6 (E1) | SB - BR | Shift lever position signal | Power switch on (IG), shift lever in N | 11 to 14 V |
| Power switch on (IG), shift lever not in N | 1.2 to 2.8 V | |||
| A39-13 (B) - I3-6 (E1) | GR - BR | Shift lever position signal | Power switch on (IG), shift lever in B | 11 to 14 V |
| Power switch on (IG), shift lever not in B | 0.5 to 1.5 V | |||
| A39-14 (R) - I3-6 (E1) | L - BR | Shift lever position signal | Power switch on (IG), shift lever in R | 11 to 14 V |
| Power switch on (IG), shift lever not in R | 0.5 to 1.5 V | |||
| A39-15 (P) - I3-6 (E1) | G - BR | Shift lever position signal | Power switch on (IG), shift lever in P | 11 to 14 V |
| Power switch on (IG), shift lever not in P | 0.5 to 1.5 V | |||
| A39-16 (MJ) - I3-6 (E1) | V - BR | Shift lever position signal | Power switch on (IG), shift lever in P, R, N, D or B | 11 to 14 V |
| A39-18 (VCP1) - A39-34 (EP1) | B - LG | Accelerator pedal sensor assembly power source (for VPA1) | Power switch on (IG) | 4.5 to 5.5 V |
| A39-19 (VCP2) - A39-35 (EP2) | W - Y | Accelerator pedal sensor assembly power source (for VPA2) | Power switch on (IG) | 4.5 to 5.5 V |
| A39-20 (CLK-) - I3-6 (E1) | W - BR | MG communication clock signal | Power switch on (READY) | Pulse generation (Waveform 6) |
| A39-21 (CLK+) - I3-6 (E1) | B - BR | MG communication clock signal | Power switch on (READY) | Pulse generation (Waveform 6) |
| A39-23 (STP) - I3-6 (E1) | W - BR | Stop light switch | Brake pedal depressed | 11 to 14 V |
| Brake pedal released | 0 to 1.5 V | |||
| A39-24 (HTM+) - I3-6 (E1) | B - BR | Communication signal from power management control ECU to MG ECU | Power switch on (READY) | Pulse generation (Waveform 7) |
| A39-25 (HTM-) - I3-6 (E1) | W - BR | Communication signal from power management control ECU to MG ECU | Power switch on (READY) | Pulse generation (Waveform 7) |
| A39-26 (VPA1) - A39-34 (EP1) | R - LG | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Power switch on (IG), accelerator pedal released | 0.4 to 1.4 V |
| Power switch on (IG) engine stopped, shift lever in P accelerator pedal fully depressed | 2.6 to 4.5 V | |||
| A39-27 (VPA2) - A39-35 (EP2) | P - Y | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Power switch on (IG), accelerator pedal released | 1.0 to 2.2 V |
| Power switch on (IG) engine stopped, shift lever in P accelerator pedal fully depressed | 3.4 to 5.3 V | |||
| A39-29 (MTH-) - I3-6 (E1) | Y - BR | Communication signal from MG ECU to power management control ECU | Power switch on (READY) | Pulse generation (Waveform 8) |
| A39-30 (MTH+) - I3-6 (E1) | L - BR | Communication signal from MG ECU to power management control ECU | Power switch on (READY) | Pulse generation (Waveform 8) |
| A39-31 (HSDN) - I3-6 (E1) | B - BR | MG ECU shutdown signal | Power switch on (READY) | 0 to 1.5 V |
| A39-32 (REQ-) - I3-6 (E1) | Y - BR | MG ECU communication request signal | Power switch on (READY) | Pulse generation (Waveform 9) |
| A39-33 (REQ+) - I3-6 (E1) | L - BR | MG ECU communication request signal | Power switch on (READY) | Pulse generation (Waveform 9) |
| I3-1 (AM22) - I3-6 (E1) | SB - BR | Constant power source | Power switch on (IG) | 11 to 14 V |
| Power switch on (READY) | 11 to 15.5 V | |||
| I3-2 (SMRG) - I3-5 (E01) | R - W-B | System main relay operation signal | Power switch on (IG)→Power switch on (READY) | Pulse generation (Waveform 10) |
| I3-3 (SMRP) - I3-5 (E01) | B - W-B | System main relay operation signal | Power switch on (IG)→Power switch on (READY) | Pulse generation (Waveform 10) |
| I3-4 (SMRB) - I3-5 (E01) | GR - W-B | System main relay operation signal | Power switch on (IG)→Power switch on (READY) | Pulse generation (Waveform 10) |
| I3-7 (SSW1) - I3-6 (E1) | R - BR | Power switch | Power switch pressed and held | 0 to 1.5 V |
| I3-11 (TC) - I3-6 (E1) | R - BR | Diagnosis terminal | Power switch on (IG) | 11 to 14 V |
| I3-13 (EVSW) - I3-6 (E1) | Y - BR | EV drive mode switch (pattern select switch assembly) signal | Power switch on (IG), EV drive mode switch (pattern select switch assembly) not operated | 11 to 14 V |
| Power switch on (IG), EV drive mode switch (pattern select switch assembly) operated | 0 to 1.5 V | |||
| I3-14 (SPDI) - I3-6 (E1) | V - BR | Vehicle speed signal | Driving at approximately 20 km/h (12 mph) with power switch on (READY) | Pulse generation (Waveform 11) |
| I3-28 (THB) - I3-30 (ETHB) | SB - LG | Auxiliary battery temperature | Power switch on (IG), auxiliary battery temperature 25°C (77°F) | 1.7 to 2.3 V |
| Power switch on (IG), auxiliary battery temperature 60°C (140°F) | 0.6 to 0.9 V | |||
| I3-29 (ABFS) - I3-6 (E1) | G - BR | Airbag activation signal | Power switch on (READY) | Pulse generation (Waveform 12) |
| I3-32 (BTH+) - I3-6 (E1) | B - BR | Communication signal from battery smart unit to power management control ECU | Power switch on (IG) | Pulse generation (Waveform 13) |
| I3-33 (BTH-) - I3-6 (E1) | W - BR | Communication signal from battery smart unit to power management control ECU | Power switch on (IG) | Pulse generation (Waveform 13) |
| I4-1 (ACCD) - I3-6 (E1) | W - BR | ACC relay | Power switch on (ACC) | 11 to 14 V |
| I4-2 (IG1D) - I3-6 (E1) | P - BR | IG1 relay | Power switch on (IG) | 11 to 14 V |
| I4-7 (AM21) - I3-6 (E1) | L - BR | Constant power source | Power switch on (IG) | 11 to 14 V |
| Power switch on (READY) | 11 to 15.5 V | |||
| I4-11 (LIN2) - I3-6 (E1) | Y - BR | LIN communication signal | Power switch on (IG) | Pulse generation |
| I4-17 (SSW2) - I3-6 (E1) | V - BR | Power switch | Power switch pressed and held | 0 to 1.5 V |
| I4-24 (CA1L) - I3-6 (E1) | W - BR | CAN communication signal | Power switch on (IG) | Pulse generation (Waveform 14) |
| I4-25 (CA1H) - I3-6 (E1) | G - BR*1 BE - BR*2 | CAN communication signal | Power switch on (IG) | Pulse generation (Waveform 14) |
| I4-30 (CA3N) - I3-6 (E1) | W - BR | CAN communication signal | Power switch on (IG) | Pulse generation (Waveform 15) |
| I4-31 (CA3P) - I3-6 (E1) | B - BR | CAN communication signal | Power switch on (IG) | Pulse generation (Waveform 15) |
| Oscilloscope waveforms |
![]() |
Waveform 1 (DC/DC operation monitor / voltage change signal)
| Item | Content |
| Terminal | A38-11 (VLO) - I3-6 (E1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 2 (Inverter water pump assembly signal)
| Item | Content |
| Terminal | CH1: A38-13 (IWP) - I3-6 (E1) CH2: A38-14 (NIWP) - I3-6 (E1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 3 (Camshaft position sensor signal)
| Item | Content |
| Terminal | A38-16 (GI) - I3-6 (E1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (READY), with engine running |
![]() |
Waveform 4 (A/C communication signal)
| Item | Content |
| Terminal | CH1: A38-19 (CLK) - I3-6 (E1) CH2: A38-31 (ITE) - I3-6 (E1) CH3: A38-30 (ETI) - I3-6 (E1) CH4: A38-20 (STB) - I3-6 (E1) |
| Equipment Setting | 10 V/DIV., 100 ms./DIV. |
| Condition | Power switch on (READY), air conditioning system stopped |
![]() |
Waveform 5 (HV battery blower fan operation signal)
| Item | Content |
| Terminal | A38-29 (SI0) - I3-6 (E1) |
| Equipment Setting | 5 V/DIV., 500 ms./DIV. |
| Condition | Power switch on (IG), during Active Test |
![]() |
Waveform 6 (MG communication clock signal)
| Item | Content |
| Terminal | CH1: A39-21 (CLK+) - I3-6 (E1) CH2: A39-20 (CLK-) - I3-6 (E1) |
| Equipment Setting | 1 V/DIV., 1 μs./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 7 (communication signal from power management control ECU to MG ECU)
| Item | Content |
| Terminal | CH1: A39-24 (HTM+) - I3-6 (E1) CH2: A39-25 (HTM-) - I3-6 (E1) |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 8 (communication signal from MG ECU to power management control ECU)
| Item | Content |
| Terminal | CH1: A39-30 (MTH+) - I3-6 (E1) CH2: A39-29 (MTH-) - I3-6 (E1) |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 9 (MG ECU communication request signal)
| Item | Content |
| Terminal | CH1: A39-33 (REQ+) - I3-6 (E1) CH2: A39-32 (REQ-) - I3-6 (E1) |
| Equipment Setting | 1 V/DIV., 1 ms./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 10 (system main relay operation signal)
| Item | Content |
| Terminal | CH1: I3-3 (SMRP) - I3-5 (E01) CH2: I3-4 (SMRB) - I3-5 (E01) CH3: I3-2 (SMRG) - I3-5 (E01) |
| Equipment Setting | 10 V/DIV., 200 ms./DIV. |
| Condition | Power switch on (IG) → Power switch on (READY) |
![]() |
Waveform 11 (vehicle speed signal)
| Item | Content |
| Terminal | I3-14 (SPDI) - I3-6 (E1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Driving at approximately 20 km/h (12 mph) with power switch on (READY) |
![]() |
Waveform 12 (airbag activation signal)
| Item | Content |
| Terminal | I3-29 (ABFS) - I3-6 (E1) |
| Equipment Setting | 5 V/DIV., 500 ms./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 13 (communication signal from battery smart unit to power management control ECU)
| Item | Content |
| Terminal | CH1: I3-32 (BTH+) - I3-6 (E1) CH2: I3-33 (BTH-) - I3-6 (E1) |
| Equipment Setting | 2 V/DIV., 500 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 14 (CAN communication signal)
| Item | Content |
| Terminal | CH1: I4-25 (CA1H) - I3-6 (E1) CH2: I4-24 (CA1L) - I3-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 15 (CAN communication signal)
| Item | Content |
| Terminal | CH1: I4-31 (CA3P) - I3-6 (E1) CH2: I4-30 (CA3N) - I3-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |

| *1 | Inverter with Converter Assembly | - | - |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Standard Condition |
| A14-1 (GI) - A14-10 (GND1) | B - W-B | Camshaft position sensor signal | Power switch on (READY), with engine running | Pulse generation (Waveform 1) |
| A14-5 (ILKO) - A14-10 (GND1) | R - W-B | Interlock switch signal | Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) and service plug grip installed correctly | Below 1 V |
| Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) or service plug grip not installed | 11 to 14 | |||
| A14-7 (CLK+) - A14-10 (GND1) | B - W-B | MG ECU communication clock signal | Power switch on (READY) | Pulse generation (Waveform 2) |
| A14-8 (MTH+) - A14-10 (GND1) | L - W-B | Communication signal from MG ECU to power management control ECU | Power switch on (READY) | Pulse generation (Waveform 3) |
| A14-9 (HTM+) - A14-10 (GND1) | B - W-B | Communication signal from power management control ECU to MG ECU | Power switch on (READY) | Pulse generation (Waveform 4) |
| A14-16 (ILKI) - A14-10 (GND1) | L - W-B | Interlock switch signal | Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) and service plug grip installed correctly | Below 1 V |
| Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) or service plug grip not installed | 11 to 14 | |||
| A14-18 (CLK-) - A14-10 (GND1) | W - W-B | MG ECU communication clock signal | Power switch on (READY) | Pulse generation (Waveform 2) |
| A14-19 (MTH-) - A14-10 (GND1) | Y - W-B | Communication signal from MG ECU to power management control ECU | Power switch on (READY) | Pulse generation (Waveform 3) |
| A14-20 (HTM-) - A14-10 (GND1) | W - W-B | Communication signal from power management control ECU to MG ECU | Power switch on (READY) | Pulse generation (Waveform 4) |
| A14-26 (REQ+) - A14-10 (GND1) | L - W-B | MG ECU communication request signal | Power switch on (READY) | Pulse generation (Waveform 5) |
| A14-30 (+B) - A14-10 (GND1) | G - W-B | MG ECU power source | Power switch on (IG) | 11 to 14 V |
| A14-31 (+B2) - A14-10 (GND1) | R - W-B | MG ECU power source | Power switch on (IG) | 11 to 14 V |
| A14-37 (REQ-) - A14-10 (GND1) | Y - W-B | MG ECU communication request signal | Power switch on (READY) | Pulse generation (Waveform 5) |
| A14-40 (HSDN) - A14-10 (GND1) | B - W-B | MG ECU shutdown signal | Power switch on (READY) | 0 to 1 V |
| E1-1 (GRF) - E1-7 (GRFG) | B - G | Generator resolver signal | Generator resolver running | Pulse generation (Waveform 6) |
| E1-2 (GSN) - E1-8 (GSNG) | L - R | Generator resolver signal | Generator resolver running | Pulse generation (Waveform 6) |
| E1-3 (GCS) - E1-9 (GCSG) | W - Y | Generator resolver signal | Generator resolver running | Pulse generation (Waveform 6) |
| E1-4 (MRF) - E1-11 (MRFG) | B - G | Motor resolver signal | Motor resolver running | Pulse generation (Waveform 7) |
| E1-5 (MSN) - E1-12 (MSNG) | L - R | Motor resolver signal | Motor resolver running | Pulse generation (Waveform 7) |
| E1-6 (MCS) - E1-13 (MCSG) | W - Y | Motor resolver signal | Motor resolver running | Pulse generation (Waveform 7) |
| A13-1 (IGCT) - A14-10 (GND1) | V - W-B | MG ECU power source | Power switch on (IG) | 11 to 14 V |
| A13-2 (IDH) - A14-10 (GND1) | G - W-B | PTC heater prohibit signal | Power switch on (IG) | 4 to 6 V |
| A13-3 (S) - A14-10 (GND1) | W - W-B | Auxiliary battery voltage monitor | Power switch on (IG) | 11 to 14 V |
| A13-5 (NODD) - A14-10 (GND1) | SB - W-B | DC/DC operation | DC/DC converter operating normally | 5 to 7 V |
| DC/DC converter not operating normally | 2 to 4 V | |||
| DC/DC converter operation prohibited | 0.1 to 0.5 V | |||
| A13-6 (VLO) - A14-10 (GND1) | BE - W-B | DC/DC operation monitor / Voltage change signal | Power switch on (IG) | Pulse generation (Waveform 8) |
| Oscilloscope waveforms |
![]() |
Waveform 1 (Camshaft position sensor signal)
| Item | Content |
| Terminal | A14-1 (GI) - A14-10 (GND1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (READY), with engine running |
![]() |
Waveform 2 (MG ECU communication clock signal)
| Item | Content |
| Terminal | CH1: A14-7 (CLK+) - A14-10 (GND1) CH2: A14-18 (CLK-) - A14-10 (GND1) |
| Equipment Setting | 1 V/DIV., 1 μs./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 3 (communication signal from MG ECU to power management control ECU)
| Item | Content |
| Terminal | CH1: A14-8 (MTH+) - A14-10 (GND1) CH2: A14-19 (MTH-) - A14-10 (GND1) |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 4 (communication signal from power management control ECU to MG ECU)
| Item | Content |
| Terminal | CH1: A14-9 (HTM+) - A14-10 (GND1) CH2: A14-20 (HTM-) - A14-10 (GND1) |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 5 (MG ECU communication request signal)
| Item | Content |
| Terminal | CH1: A14-26 (REQ+) - A14-10 (GND1) CH2: A14-37 (REQ-) - A14-10 (GND1) |
| Equipment Setting | 1 V/DIV., 1 ms./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 6 (generator resolver signal)
| Item | Content |
| Terminal | CH1: E1-1 (GRF) - E1-7 (GRFG) CH2: E1-2 (GSN) - E1-8 (GSNG) CH3: E1-3 (GCS) - E1-9 (GCSG) |
| Equipment Setting | CH1: 10 V/DIV., 1 ms./DIV. CH2, 3: 5 V/DIV., 1 ms./DIV. |
| Condition | Generator resolver running |
![]() |
Waveform 7 (motor resolver signal)
| Item | Content |
| Terminal | CH1: E1-4 (MRF) - E1-11 (MRFG) CH2: E1-5 (MSN) - E1-12 (MSNG) CH3: E1-6 (MCS) - E1-13 (MCSG) |
| Equipment Setting | CH1: 10 V/DIV., 1 ms./DIV. CH2, 3: 5 V/DIV., 1 ms./DIV. |
| Condition | Motor resolver running |
![]() |
Waveform 8 (DC/DC operation monitor / voltage change signal)
| Item | Content |
| Terminal | A13-6 (VLO) - A14-10 (GND1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Power switch on (IG) |