Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

HYBRID CONTROL SYSTEM > TERMINALS OF ECU

for Preparation Click here



C146689E48


Text in Illustration 
*1
Power Management Control ECU
-
-

Power management control ECU 
Terminal No.
(Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
A38-1 (+B2) - I3-6 (E1)
B - BR
Power source
Power switch on (IG)
11 to 14 V
A38-4 (MREL) - I3-6 (E1)
V - BR
Main relay
Power switch on (IG)
11 to 14 V
A38-6 (ST1-) - I3-6 (E1)
GR - BR
Brake cancel switch
Power switch on (IG), brake pedal depressed
0 to 1.5 V
Power switch on (IG), brake pedal released
11 to 14 V
A38-9 (PSFT) - I3-6 (E1)
B - BR
Shift lever position sensor power source
Power switch on (IG)
11 to 14 V
A38-10 (ACCI) - I3-6 (E1)
B - BR
Power source
Power switch on (ACC)
11 to 14 V
A38-12 (NIWP) - I3-6 (E1)
R - BR
Inverter water pump assembly signal
Power switch on (READY)
Pulse generation
(Waveform 1)
A38-13 (IWP) - I3-6 (E1)
LG - BR
Inverter water pump assembly signal
Power switch on (READY)
Pulse generation
(Waveform 1)
A38-14 (VLO) - I3-6 (E1)
BE - BR
DC/DC operation monitor / voltage change signal
Power switch on (IG)
Pulse generation
(Waveform 2)
A38-19 (GI) - I3-6 (E1)
B - BR
Camshaft position sensor signal
Power switch on (READY), with engine running
Pulse generation
(Waveform 3)
A38-20 (MTH-) - I3-6 (E1)
Y - BR
Communication signal from MG ECU to power management control ECU
Power switch on (READY)
Pulse generation
(Waveform 4)
A38-21 (MTH+) - I3-6 (E1)
L - BR
Communication signal from MG ECU to power management control ECU
Power switch on (READY)
Pulse generation
(Waveform 4)
A38-22 (ILK) - I3-6 (E1)
L - BR
Interlock switch
Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) and service plug grip installed correctly
0 to 1.5 V
Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) or service plug grip not installed
11 to 14 V
A38-23 (NODD) - I3-6 (E1)
SB - BR
DC/DC operation
DC/DC converter operating normally
5 to 7 V
DC/DC converter not operating normally
2 to 4 V
DC/DC converter operating prohibited
0.1 to 0.5 V
A38-28 (CLK-) - I3-6 (E1)
W - BR
MG communication clock signal
Power switch on (READY)
Pulse generation
(Waveform 5)
A38-29 (CLK+) - I3-6 (E1)
B - BR
MG communication clock signal
Power switch on (READY)
Pulse generation
(Waveform 5)
A38-30 (HSDN) - I3-6 (E1)
B - BR
MG ECU shutdown signal
Power switch on (READY)
0 to 1.5 V
A38-31 (REQ-) - I3-6 (E1)
Y - BR
MG ECU communication request signal
Power switch on (READY)
Pulse generation
(Waveform 6)
A38-32 (REQ+) - I3-6 (E1)
L - BR
MG ECU communication request signal
Power switch on (READY)
Pulse generation
(Waveform 6)
A38-33 (HTM-) - I3-6 (E1)
W - BR
Communication signal from power management control ECU to MG ECU
Power switch on (READY)
Pulse generation
(Waveform 7)
A38-34 (HTM+) - I3-6 (E1)
B - BR
Communication signal from power management control ECU to MG ECU
Power switch on (READY)
Pulse generation
(Waveform 7)
A39-1 (IG2) - I3-6 (E1)
BE - BR
Power source
Power switch on (IG)
11 to 14 V
A39-2 (IG2D) - I3-6 (E1)
R - BR
IG2 relay
Power switch on (IG)
11 to 14 V
A39-3 (+B1) - I3-6 (E1)
B - BR
Power source
Power switch on (IG)
11 to 14 V
A39-8 (FD) - I3-6 (E1)
LG - BR
Shift lever position signal
Power switch on (IG), shift lever in D or B
11 to 14 V
Power switch on (IG), shift lever not in D or B
0.5 to 1.5 V
A39-9 (RV) - I3-6 (E1)
P - BR
Shift lever position signal
Power switch on (IG), shift lever in R
11 to 14 V
Power switch on (IG), shift lever not in R
0.5 to 1.5 V
A39-10 (D) - I3-6 (E1)
Y - BR
Shift lever position signal
Power switch on (IG), shift lever in D
11 to 14 V
Power switch on (IG), shift lever not in D
0.5 to 1.5 V
A39-11 (N) - I3-6 (E1)
SB - BR
Shift lever position signal
Power switch on (IG), shift lever in N
11 to 14 V
Power switch on (IG), shift lever not in N
1.2 to 2.8 V
A39-12 (B) - I3-6 (E1)
GR - BR
Shift lever position signal
Power switch on (IG), shift lever in B
11 to 14 V
Power switch on (IG), shift lever not in B
0.5 to 1.5 V
A39-13 (R) - I3-6 (E1)
L - BR
Shift lever position signal
Power switch on (IG), shift lever in R
11 to 14 V
Power switch on (IG), shift lever not in R
0.5 to 1.5 V
A39-14 (P) - I3-6 (E1)
G - BR
Shift lever position signal
Power switch on (IG), shift lever in P
11 to 14 V
Power switch on (IG), shift lever not in P
0.5 to 1.5 V
A39-15 (MJ) - I3-6 (E1)
V - BR
Shift lever position signal
Power switch on (IG), shift lever in P, R, N, D or B
11 to 14 V
A39-16 (CLK) - I3-6 (E1)
GR - BR
A/C communication signal
Power switch on (READY), air conditioning system stopped
Pulse generation
(Waveform 8)
A39-17 (ITE) - I3-6 (E1)
W - BR
A/C communication signal
Power switch on (READY), air conditioning system stopped
Pulse generation
(Waveform 8)
A39-18 (ETI) - I3-6 (E1)
Y - BR
A/C communication signal
Power switch on (READY), air conditioning system stopped
Pulse generation
(Waveform 8)
A39-19 (STB) - I3-6 (E1)
V - BR
A/C communication signal
Power switch on (READY), air conditioning system stopped
Pulse generation
(Waveform 8)
A39-22 (VPA2) - A39-20 (EP2)
P - Y
Accelerator pedal sensor assembly (for accelerator pedal position detection)
Power switch on (IG), accelerator pedal released
1.0 to 2.2 V
Power switch on (IG) engine stopped, shift lever in P accelerator pedal fully depressed
3.4 to 5.3 V
A39-23 (VPA1) - A39-21 (EP1)
R - LG
Accelerator pedal sensor assembly (for accelerator pedal position detection)
Power switch on (IG), accelerator pedal released
0.4 to 1.4 V
Power switch on (IG) engine stopped, shift lever in P accelerator pedal fully depressed
2.6 to 4.5 V
A39-27 (GMT) - A39-26 (GMTG)
L - P
Generator temperature sensor
Power switch on (IG), temperature 25°C (77°F)
3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F)
2.2 to 3.2 V
A39-29 (VCP1) - A39-21 (EP1)
B - LG
Accelerator pedal sensor assembly power source (for VPA1)
Power switch on (IG)
4.5 to 5.5 V
A39-30 (VCP2) - A39-20 (EP2)
W - Y
Accelerator pedal sensor assembly power source (for VPA2)
Power switch on (IG)
4.5 to 5.5 V
A39-35 (MMT) - A39-34 (MMTG)
G - GR
Motor temperature sensor
Power switch on (IG), temperature 25°C (77°F)
3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F)
2.2 to 3.2 V
I3-1 (AM22) - I3-6 (E1)
SB - BR
Constant power source
Power switch on (IG)
11 to 14 V
Power switch on (READY)
11 to 15.5 V
I3-2 (SMRG) - I3-5 (E01)
R - W-B
System main relay operation signal
Power switch on (IG)→Power switch on (READY)
Pulse generation
(Waveform 9)
I3-3 (SMRP) - I3-5 (E01)
B - W-B
System main relay operation signal
Power switch on (IG)→Power switch on (READY)
Pulse generation
(Waveform 9)
I3-4 (SMRB) - I3-5 (E01)
GR - W-B
System main relay operation signal
Power switch on (IG)→Power switch on (READY)
Pulse generation
(Waveform 9)
I3-7 (SSW1) - I3-6 (E1)
R - BR
Power switch
Power switch pressed and held
0 to 1.5 V
I3-8 (BL) - I3-6 (E1)
W - BR
Back up light
Power switch on (IG), shift lever in R
11 to 14 V
I3-16 (SPDI) - I3-6 (E1)
V - BR
Vehicle speed signal
Driving at approximately 20 km/h (12 mph) with power switch on (READY)
Pulse generation
(Waveform 10)
I3-17 (SI0) - I3-6 (E1)
GR - BR
HV battery blower fan operation signal
Power switch on (IG), during Active Test
Pulse generation
(Waveform 11)
I3-20 (INDB) - I3-6 (E1)
L - BR
Shift position indicator signal
Power switch on (IG), shift lever in D or B
0 to 3.2 V
Power switch on (IG), shift lever not in D or B
11 to 14 V
I3-22 (INDD) - I3-6 (E1)
P - BR
Shift position indicator signal
Power switch on (IG), shift lever in D
0 to 3.2 V
Power switch on (IG), shift lever not in D
11 to 14 V
I3-27 (THB) - I3-26 (ETHB)
SB - LG
Auxiliary battery temperature
Power switch on (IG), auxiliary battery temperature 25°C (77°F)
1.7 to 2.3 V
Power switch on (IG), auxiliary battery temperature 60°C (140°F)
0.6 to 0.9 V
I3-29 (BTH-) - I3-6 (E1)
W - BR
Communication signal from battery smart unit to power management control ECU
Power switch on (IG)
Pulse generation
(Waveform 12)
I3-30 (BTH+) - I3-6 (E1)
B - BR
Communication signal from battery smart unit to power management control ECU
Power switch on (IG)
Pulse generation
(Waveform 12)
I3-31 (INDN) - I3-6 (E1)
V - BR
Shift position indicator signal
Power switch on (IG), shift lever in N
0 to 3.2 V
Power switch on (IG), shift lever not in N
11 to 14 V
I3-32 (INDR) - I3-6 (E1)
R - BR
Shift position indicator signal
Power switch on (IG), shift lever in R
0 to 3.2 V
Power switch on (IG), shift lever not in R
11 to 14 V
I3-33 (INDP) - I3-6 (E1)
W - BR
Shift position indicator signal
Power switch on (IG), shift lever in P
0 to 3.2 V
Power switch on (IG), shift lever not in P
11 to 14 V
I4-1 (ACCD) - I3-6 (E1)
W - BR
ACC relay
Power switch on (ACC)
11 to 14 V
I4-2 (IG1D) - I3-6 (E1)
P - BR
IG1 relay
Power switch on (IG)
11 to 14 V
I4-7 (AM21) - I3-6 (E1)
L - BR
Constant power source
Power switch on (IG)
11 to 14 V
Power switch on (READY)
11 to 15.5 V
I4-8 (TC) - I3-6 (E1)
R - BR
Diagnosis terminal
Power switch on (IG)
11 to 14 V
I4-9 (EVSW) - I3-6 (E1)
Y - BR
EV drive mode switch (pattern select switch assembly) signal
Power switch on (IG), EV drive mode switch (pattern select switch assembly) not operated
11 to 14 V
Power switch on (IG), EV drive mode switch (pattern select switch assembly) operated
0 to 1.5 V
I4-10 (STP) - I3-6 (E1)
GR - BR
Stop light switch
Brake pedal depressed
11 to 14 V
Brake pedal released
0 to 1.5 V
I4-11 (LIN2) - I3-6 (E1)
Y - BR
LIN communication signal
Power switch on (IG)
Pulse generation
I4-13 (ABFS) - I3-6 (E1)
G - BR
Airbag activation signal
Power switch on (READY)
Pulse generation
(Waveform 13)
I4-17 (SSW2) - I3-6 (E1)
V - BR
Power switch
Power switch pressed and held
0 to 1.5 V
I4-24 (CA1L) - I3-6 (E1)
W - BR
CAN communication signal
Power switch on (IG)
Pulse generation
(Waveform 14)
I4-25 (CA1H) - I3-6 (E1)
G - BR*1
BE - BR*2
CAN communication signal
Power switch on (IG)
Pulse generation
(Waveform 14)
I4-30 (CA3N) - I3-6 (E1)
W - BR
CAN communication signal
Power switch on (IG)
Pulse generation
(Waveform 15)
I4-31 (CA3P) - I3-6 (E1)
B - BR
CAN communication signal
Power switch on (IG)
Pulse generation
(Waveform 15)
  1. *1: for LHD
  2. *2: for RHD

Oscilloscope waveforms

HINT:
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.



    C206008E03
  1. Waveform 1 (Inverter water pump assembly signal)
    Item
    Content
    Terminal
    CH1: A38-13 (IWP) - I3-6 (E1)
    CH2: A38-12 (NIWP) - I3-6 (E1)
    Equipment Setting
    5 V/DIV., 50 ms./DIV.
    Condition
    Power switch on (READY)



  2. A217985E01
  3. Waveform 2 (DC/DC operation monitor / voltage change signal)
    Item
    Content
    Terminal
    A38-14 (VLO) - I3-6 (E1)
    Equipment Setting
    5 V/DIV., 50 ms./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The cycle will vary depending on the specified voltage of the hybrid vehicle converter.



  4. A217984E01
  5. Waveform 3 (Camshaft position sensor signal)
    Item
    Content
    Terminal
    A38-19 (GI) - I3-6 (E1)
    Equipment Setting
    5 V/DIV., 20 ms./DIV.
    Condition
    Power switch on (READY), with engine running

    HINT:
    The pulse cycle becomes shorter as the engine speed increases.



  6. A114529E01
  7. Waveform 4 (communication signal from MG ECU to power management control ECU)
    Item
    Content
    Terminal
    CH1: A38-21 (MTH+) - I3-6 (E1)
    CH2: A38-20 (MTH-) - I3-6 (E1)
    Equipment Setting
    1 V/DIV., 200 μs./DIV.
    Condition
    Power switch on (READY)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  8. A111604E01
  9. Waveform 5 (MG communication clock signal)
    Item
    Content
    Terminal
    CH1: A38-29 (CLK+) - I3-6 (E1)
    CH2: A38-28 (CLK-) - I3-6 (E1)
    Equipment Setting
    1 V/DIV., 1 μs./DIV.
    Condition
    Power switch on (READY)



  10. A111605E01
  11. Waveform 6 (MG ECU communication request signal)
    Item
    Content
    Terminal
    CH1: A38-32 (REQ+) - I3-6 (E1)
    CH2: A38-31 (REQ-) - I3-6 (E1)
    Equipment Setting
    1 V/DIV., 1 ms./DIV.
    Condition
    Power switch on (READY)



  12. A114529E01
  13. Waveform 7 (communication signal from power management control ECU to MG ECU)
    Item
    Content
    Terminal
    CH1: A38-34 (HTM+) - I3-6 (E1)
    CH2: A38-33 (HTM-) - I3-6 (E1)
    Equipment Setting
    1 V/DIV., 200 μs./DIV.
    Condition
    Power switch on (READY)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  14. A111607E01
  15. Waveform 8 (A/C communication signal)
    Item
    Content
    Terminal
    CH1: A39-16 (CLK) - I3-6 (E1)
    CH2: A39-17 (ITE) - I3-6 (E1)
    CH3: A39-18 (ETI) - I3-6 (E1)
    CH4: A39-19 (STB) - I3-6 (E1)
    Equipment Setting
    10 V/DIV., 100 ms./DIV.
    Condition
    Power switch on (READY), air conditioning system stopped

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  16. C206010E02
  17. Waveform 9 (system main relay operation signal)
    Item
    Content
    Terminal
    CH1: I3-3 (SMRP) - I3-5 (E01)
    CH2: I3-4 (SMRB) - I3-5 (E01)
    CH3: I3-2 (SMRG) - I3-5 (E01)
    Equipment Setting
    10 V/DIV., 200 ms./DIV.
    Condition
    Power switch on (IG) → Power switch on (READY)



  18. A111593E03
  19. Waveform 10(vehicle speed signal)
    Item
    Content
    Terminal
    I3-16 (SPDI) - I3-6 (E1)
    Equipment Setting
    5 V/DIV., 20 ms./DIV.
    Condition
    Driving at approximately 20 km/h (12 mph) with power switch on (READY)

    HINT:
    The higher the vehicle speed, the shorter the cycle.



  20. A256953E01
  21. Waveform 11 (HV battery blower fan operation signal)
    Item
    Content
    Terminal
    I3-17 (SI0) - I3-6 (E1)
    Equipment Setting
    5 V/DIV., 500 ms./DIV.
    Condition
    Power switch on (IG), during Active Test

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  22. A111597E01
  23. Waveform 12(communication signal from battery smart unit to power management control ECU)
    Item
    Content
    Terminal
    CH1: I3-30 (BTH+) - I3-6 (E1)
    CH2: I3-29 (BTH-) - I3-6 (E1)
    Equipment Setting
    2 V/DIV., 500 μs./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  24. A111590E01
  25. Waveform 13(airbag activation signal)
    Item
    Content
    Terminal
    I4-13 (ABFS) - I3-6 (E1)
    Equipment Setting
    5 V/DIV., 500 ms./DIV.
    Condition
    Power switch on (READY)



  26. A111598E01
  27. Waveform 14 (CAN communication signal)
    Item
    Content
    Terminal
    CH1: I4-25 (CA1H) - I3-6 (E1)
    CH2: I4-24 (CA1L) - I3-6 (E1)
    Equipment Setting
    1 V/DIV., 50 μs./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  28. A111598E01
  29. Waveform 15 (CAN communication signal)
    Item
    Content
    Terminal
    CH1: I4-31 (CA3P) - I3-6 (E1)
    CH2: I4-30 (CA3N) - I3-6 (E1)
    Equipment Setting
    1 V/DIV., 50 μs./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).


A259502E01


Text in Illustration 
*1
Inverter with Converter Assembly
-
-

HINT:
Since the inverter with converter assembly uses waterproof connectors, the voltage and waveform cannot be inspected directly. Standard voltage readings and waveforms are indicated for reference only.


Inverter with converter assembly 
Terminal No.
(Symbol)
Wiring Color
Terminal Description
Condition
Standard Condition
A14-1 (GI) - A14-10 (GND1)
B - W-B
Camshaft position sensor signal
Power switch on (READY), with engine running
Pulse generation
(Waveform 1)
A14-5 (ILKO) - A14-10 (GND1)
R - W-B
Interlock switch signal
Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) and service plug grip installed correctly
Below 1 V
Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) or service plug grip not installed
11 to 14
A14-7 (CLK+) - A14-10 (GND1)
B - W-B
MG ECU communication clock signal
Power switch on (READY)
Pulse generation
(Waveform 2)
A14-8 (MTH+) - A14-10 (GND1)
L - W-B
Communication signal from MG ECU to power management control ECU
Power switch on (READY)
Pulse generation
(Waveform 3)
A14-9 (HTM+) - A14-10 (GND1)
B - W-B
Communication signal from power management control ECU to MG ECU
Power switch on (READY)
Pulse generation
(Waveform 4)
A14-16 (ILKI) - A14-10 (GND1)
L - W-B
Interlock switch signal
Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) and service plug grip installed correctly
Below 1 V
Power switch on (IG), connector cover assembly, upper inverter cover, No. 4 engine wire (air conditioner wire) or service plug grip not installed
11 to 14
A14-18 (CLK-) - A14-10 (GND1)
W - W-B
MG ECU communication clock signal
Power switch on (READY)
Pulse generation
(Waveform 2)
A14-19 (MTH-) - A14-10 (GND1)
Y - W-B
Communication signal from MG ECU to power management control ECU
Power switch on (READY)
Pulse generation
(Waveform 3)
A14-20 (HTM-) - A14-10 (GND1)
W - W-B
Communication signal from power management control ECU to MG ECU
Power switch on (READY)
Pulse generation
(Waveform 4)
A14-26 (REQ+) - A14-10 (GND1)
L - W-B
MG ECU communication request signal
Power switch on (READY)
Pulse generation
(Waveform 5)
A14-30 (+B) - A14-10 (GND1)
G - W-B
MG ECU power source
Power switch on (IG)
11 to 14 V
A14-31 (+B2) - A14-10 (GND1)
R - W-B
MG ECU power source
Power switch on (IG)
11 to 14 V
A14-37 (REQ-) - A14-10 (GND1)
Y - W-B
MG ECU communication request signal
Power switch on (READY)
Pulse generation
(Waveform 5)
A14-40 (HSDN) - A14-10 (GND1)
B - W-B
MG ECU shutdown signal
Power switch on (READY)
0 to 1 V
E1-1 (GRF) - E1-7 (GRFG)
B - G
Generator resolver signal
Generator resolver running
Pulse generation
(Waveform 6)
E1-2 (GSN) - E1-8 (GSNG)
L - R
Generator resolver signal
Generator resolver running
Pulse generation
(Waveform 6)
E1-3 (GCS) - E1-9 (GCSG)
W - Y
Generator resolver signal
Generator resolver running
Pulse generation
(Waveform 6)
E1-4 (MRF) - E1-11 (MRFG)
B - G
Motor resolver signal
Motor resolver running
Pulse generation
(Waveform 7)
E1-5 (MSN) - E1-12 (MSNG)
L - R
Motor resolver signal
Motor resolver running
Pulse generation
(Waveform 7)
E1-6 (MCS) - E1-13 (MCSG)
W - Y
Motor resolver signal
Motor resolver running
Pulse generation
(Waveform 7)
A13-1 (IGCT) - A14-10 (GND1)
V - W-B
MG ECU power source
Power switch on (IG)
11 to 14 V
A13-2 (IDH) - A14-10 (GND1)
G - W-B
PTC heater prohibit signal
Power switch on (IG)
4 to 6 V
A13-3 (S) - A14-10 (GND1)
W - W-B
Auxiliary battery voltage monitor
Power switch on (IG)
11 to 14 V
A13-5 (NODD) - A14-10 (GND1)
SB - W-B
DC/DC operation
DC/DC converter operating normally
5 to 7 V
DC/DC converter not operating normally
2 to 4 V
DC/DC converter operation prohibited
0.1 to 0.5 V
A13-6 (VLO) - A14-10 (GND1)
BE - W-B
DC/DC operation monitor / Voltage change signal
Power switch on (IG)
Pulse generation
(Waveform 8)

NOTICE:
Do not measure the voltage or waveform directly at the sealed side of the inverter with converter assembly connector. Doing so may damage the connector because the connector is waterproof.


Oscilloscope waveforms

HINT:
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.



    A217984E01
  1. Waveform 1 (Camshaft position sensor signal)
    Item
    Content
    Terminal
    A14-1 (GI) - A14-10 (GND1)
    Equipment Setting
    5 V/DIV., 20 ms./DIV.
    Condition
    Power switch on (READY), with engine running

    HINT:
    The pulse cycle becomes shorter as the engine speed increases.



  2. A111604E01
  3. Waveform 2 (MG ECU communication clock signal)
    Item
    Content
    Terminal
    CH1: A14-7 (CLK+) - A14-10 (GND1)
    CH2: A14-18 (CLK-) - A14-10 (GND1)
    Equipment Setting
    1 V/DIV., 1 μs./DIV.
    Condition
    Power switch on (READY)



  4. A114529E01
  5. Waveform 3 (communication signal from MG ECU to power management control ECU)
    Item
    Content
    Terminal
    CH1: A14-8 (MTH+) - A14-10 (GND1)
    CH2: A14-19 (MTH-) - A14-10 (GND1)
    Equipment Setting
    1 V/DIV., 200 μs./DIV.
    Condition
    Power switch on (READY)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  6. A114529E01
  7. Waveform 4 (communication signal from power management control ECU to MG ECU)
    Item
    Content
    Terminal
    CH1: A14-9 (HTM+) - A14-10 (GND1)
    CH2: A14-20 (HTM-) - A14-10 (GND1)
    Equipment Setting
    1 V/DIV., 200 μs./DIV.
    Condition
    Power switch on (READY)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  8. A111605E01
  9. Waveform 5 (MG ECU communication request signal)
    Item
    Content
    Terminal
    CH1: A14-26 (REQ+) - A14-10 (GND1)
    CH2: A14-37 (REQ-) - A14-10 (GND1)
    Equipment Setting
    1 V/DIV., 1 ms./DIV.
    Condition
    Power switch on (READY)



  10. A111610E01
  11. Waveform 6 (generator resolver signal)
    Item
    Content
    Terminal
    CH1: E1-1 (GRF) - E1-7 (GRFG)
    CH2: E1-2 (GSN) - E1-8 (GSNG)
    CH3: E1-3 (GCS) - E1-9 (GCSG)
    Equipment Setting
    CH1: 10 V/DIV., 1 ms./DIV.
    CH2, 3: 5 V/DIV., 1 ms./DIV.
    Condition
    Generator resolver running

    HINT:
    Pulse cycle A becomes shorter as the rotor speed increases.



  12. A111610E01
  13. Waveform 7 (motor resolver signal)
    Item
    Content
    Terminal
    CH1: E1-4 (MRF) - E1-11 (MRFG)
    CH2: E1-5 (MSN) - E1-12 (MSNG)
    CH3: E1-6 (MCS) - E1-13 (MCSG)
    Equipment Setting
    CH1: 10 V/DIV., 1 ms./DIV.
    CH2, 3: 5 V/DIV., 1 ms./DIV.
    Condition
    Motor resolver running

    HINT:
    Pulse cycle A becomes shorter as the rotor speed increases.



  14. A217985E01
  15. Waveform 8 (DC/DC operation monitor / voltage change signal)
    Item
    Content
    Terminal
    A13-6 (VLO) - A14-10 (GND1)
    Equipment Setting
    5 V/DIV., 50 ms./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The cycle will vary depending on the specified voltage of the hybrid vehicle converter.