DTC P3004-131 High Voltage Power Resource |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P3004 | 131 | One of the following occurs during pre-charge (the time from when SMRP turns on until SMRG turns on):
|
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P3004-131 only is output. | A |
| DTCs shown in Table 1 are output simultaneously. | B |
| DTCs shown in Table 2 are output simultaneously. | C |
| DTC No. | Relevant Diagnosis |
| P06E6-164 | Sensor Power Supply "C" Circuit / Open |
| P0A1A-151, 658 | Generator Control Module |
| P0A1B-786 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0AE6-225 | Hybrid Battery Precharge Contactor Control Circuit Low |
| P0AE7-224 | Hybrid Battery Precharge Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range / Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C73-512 | Sensor Standard Voltage "F" Circuit / Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P2511-149 | ECM/PCM Power Relay Sense Circuit Intermittent |
| P3004-800, 801 | High Voltage Power Resource |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
| DTC No. | Relevant Diagnosis |
| P0A95-123 | High Voltage Fuse |
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0AC0-123 | Hybrid Battery Pack Current Sensor Circuit Range / Performance |
| P0AC1-123 | Hybrid Battery Pack Current Sensor "A" Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor "A" Circuit High |
| P0AFC-123 | Hybrid Battery Pack Sensor Module |
| P0B3D-123 | Hybrid Battery Voltage Sensor "A" Circuit Low |
| P0B42-123 | Hybrid Battery Voltage Sensor "B" Circuit Low |
| P0B47-123 | Hybrid Battery Voltage Sensor "C" Circuit Low |
| P0B4C-123 | Hybrid Battery Voltage Sensor "D" Circuit Low |
| P0B51-123 | Hybrid Battery Voltage Sensor "E" Circuit Low |
| P0B56-123 | Hybrid Battery Voltage Sensor "F" Circuit Low |
| P0B5B-123 | Hybrid Battery Voltage Sensor "G" Circuit Low |
| P0B60-123 | Hybrid Battery Voltage Sensor "H" Circuit Low |
| P0B65-123 | Hybrid Battery Voltage Sensor "I" Circuit Low |
| P0B6A-123 | Hybrid Battery Voltage Sensor "J" Circuit Low |
| P0B6F-123 | Hybrid Battery Voltage Sensor "K" Circuit Low |
| P0B74-123 | Hybrid Battery Voltage Sensor "L" Circuit Low |
| P0B79-123 | Hybrid Battery Voltage Sensor "M" Circuit Low |
| P0B7E-123 | Hybrid Battery Voltage Sensor "N" Circuit Low |
| P0B83-123 | Hybrid Battery Voltage Sensor "O" Circuit Low |
| P0B88-123 | Hybrid Battery Voltage Sensor "P" Circuit Low |
| P0B8D-123 | Hybrid Battery Voltage Sensor "Q" Circuit Low |
| P0B92-123 | Hybrid Battery Voltage Sensor "R" Circuit Low |
| P308A-123 | Hybrid Battery Voltage Sensor All Circuits Low |
| U029A-123 | Lost Communication with Hybrid Battery Pack Sensor Module |
Turn the power switch off.
|
| ||||
|
| ||||
| A | |
| 2.CHECK FREEZE FRAME DATA (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data of DTC P3004-131.
| Result | Proceed to |
Both of the following conditions are met:
| A |
| Other than above | B |
Turn the power switch off.
|
| ||||
| A | ||
| ||
| 3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR) |
![]() |
Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors (Click here).
|
| ||||
| OK | |
| 4.CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the connector cover assembly from the inverter with converter assembly.
![]() |
Check the connector Q1 connection condition between the No. 4 floor wire and the inverter with converter assembly.
Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.
Check for arc marks on the terminals of the No. 4 floor wire.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the No. 4 floor wire to the inverter with converter assembly.
Install the connector cover assembly to the inverter with converter assembly.
|
| ||||
|
| ||||
| A | |
| 5.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the No. 4 hybrid battery shield panel .
![]() |
Check the connector Q2 and connector Q3 connection condition between the No. 4 floor wire and the hybrid battery junction block assembly.
Disconnect connector Q2 and connector Q3 of the No. 4 floor wire from the hybrid battery junction block assembly.
Check for arc marks on the terminals of the No. 4 floor wire.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the No. 4 floor wire to the hybrid battery junction block assembly.
Install the No. 4 hybrid battery shield panel.
|
| ||||
|
| ||||
| A | |
| 6.CHECK NO. 4 FLOOR WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY) |
Check that the service plug grip is not installed.
![]() |
Remove the connector cover assembly from the inverter with converter assembly.
![]() |
Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.
Remove the No. 4 hybrid battery shield panel .
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| Q2-1 (CBI) - Q1-1 (CBI) | Power switch off | Below 1 Ω |
| Q3-1 (CEI) - Q1-2 (CEI) | Power switch off | Below 1 Ω |
| *a | Front view of No. 4 floor wire connector (to Inverter with Converter Assembly) |
| *b | Component with harness connected (Hybrid Battery Junction Block Assembly) |
Install the No. 4 hybrid battery shield panel.
Connect the No. 4 floor wire to the inverter with converter assembly.
Install the connector cover assembly to the inverter with converter assembly.
|
| ||||
| OK | |
| 7.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (HV BATTERY HIGH VOLTAGE TERMINAL CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid battery shield sub-assembly .
![]() |
Check the connections between the HV battery high voltage terminals and the hybrid battery junction block assembly.
Check for arc marks on the terminals of the HV battery high voltage terminals.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Install the No. 1 hybrid battery shield sub-assembly.
|
| ||||
|
| ||||
| A | |
| 8.CHECK HV BATTERY |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid battery shield sub-assembly .
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A-1 (+) - Service plug grip terminal 1 | Power switch off | 114 V or higher |
| q1-1 (-) - Service plug grip terminal 2 | Power switch off | 79 V or higher |
Install the No. 1 hybrid battery shield sub-assembly.
|
| ||||
| OK | |
| 9.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector I3 from the power management control ECU.
Remove the No. 4 hybrid battery shield panel .
Disconnect the connector O9 that drives the system main relay of the hybrid battery junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| I3-4 (SMRB) - O9-1 (SMRB) | Power switch off | Below 1 Ω |
| I3-3 (SMRP) - O9-4 (SMRP) | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
| *b | Rear view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Connect the hybrid battery junction block assembly connector.
Install the No. 4 hybrid battery shield panel.
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 10.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB) |
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q2-1 (CBI) - A-1 (+) | Auxiliary battery voltage is applied between terminals O9-1 (SMRB) and O9-2 (GND) | Below 1 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O9-1 (SMRB) - O9-2 (GND) | -40 to 80 °C (-40 to 176°F) | 25.0 to 59.0 Ω |
Install the hybrid battery junction block assembly.
|
| ||||
| OK | |
| 11.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP) |
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q3-1 (CEI) - q1-1 (-) | Auxiliary battery voltage is applied between terminals O9-4 (SMRP) and O9-2 (GND) | 28.5 to 31.5 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O9-4 (SMRP) - O9-2 (GND) | -40 to 80 °C (-40 to 176°F) | 112 to 274 Ω |
Install the hybrid battery junction block assembly.
|
| ||||
| OK | |
| 12.CHECK FOR INTERMITTENT PROBLEMS |
|
| ||||
| OK | ||
| ||