DTC    P0AA1-233    Hybrid Battery Positive Contactor Circuit Stuck Closed

for Preparation Click here


DESCRIPTION

  1. Refer to the description for DTC P0AE6-225 .
  2. This circuit uses the power management control ECU to monitor the system main relays and stops the system if a malfunction is detected in the relays, because it may be impossible to shut off the high-voltage system if any of the relays becomes stuck.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0AA1
233
SMRP, SMRB and SMRG on the HV battery positive and negative sides are stuck closed.
  1. Hybrid battery junction block assembly
  2. Inverter with converter assembly
  3. Power management control ECU
  4. Wire harness or connector

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AE6-225 .

INSPECTION PROCEDURE

CAUTION:
  1. When performing P0AA1-233 troubleshooting, use either a tool wrapped with vinyl insulation tape or a insulated tool. (It is extremely dangerous when a high-voltage charge passes through a non-insulated tool causing a short.)
  2. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  3. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
  1. After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).
  2. If the DTCs are cleared or the cable is disconnected and reconnected to the negative (-) auxiliary battery terminal before performing repairs, turning the power switch on (READY) may cause a malfunction. Do not turn the power switch on (READY)
  3. Do not turn the power switch on (IG) with the service plug grip removed, as this may cause a malfunction.
  4. If DTC P0AA1-233 is output, do not install the service plug grip before completing repair. If the service plug grip is not removed, the HV battery will gradually discharge and the SOC will decrease.

HINT:
If P0AA1-233 is stored, the hybrid system cannot be turned on.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0AA1-233 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P06B0-163
    Sensor Power Supply "A" Circuit/Open
    P06D6-511
    Sensor Reference Voltage "F" Circuit/Open
    P06E6-164
    Sensor Power Supply "C" Circuit/Open
    P0A1A-151, 658, 791
    Generator Control Module
    P0A1B-786, 794
    Drive Motor "A" Control Module
    P0A1D-148
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0AE7-224
    Hybrid Battery Precharge Contactor Control Circuit High
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P0CA3-442
    DC/DC Converter Step Up Voltage Performance
    P0D2E-586
    Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance
    P0D2F-266
    Drive Motor "A" Inverter Voltage Sensor Circuit Low
    P0D30-267
    Drive Motor "A" Inverter Voltage Sensor Circuit High
    P1C2A-155
    Generator A/D Converter Circuit
    P1C73-512
    Sensor Standard Voltage "F" Circuit/Open
    P1CA6-156
    Generator Control Module Malfunction
    P1CA7-193
    Drive Motor Control Module Malfunction
    P1CAC-200
    Generator Position Sensor Angle Malfunction
    P1CAD-168
    Drive Motor "A" Position Sensor Angle Malfunction
    P1CAF-792
    Generator Position Sensor REF Signal Cycle Malfunction
    P1CB0-795
    Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
    P1CB2-793
    Generator Position Sensor REF Signal Stop Malfunction
    P1CB3-796
    Drive Motor "A" Position Sensor REF Signal Stop Malfunction
    P2511-149
    HV CPU Power Relay Sense Circuit Intermittent No Continuity
    P3004-132
    Power Cable Malfunction
    P3133-659
    Communication Error from Generator to Drive Motor "A"
    P3134-661
    Communication Error from Drive Motor "A" to Generator
    P324E-788
    MG-ECU Power Relay Intermittent Circuit
    U0110 (all INF codes)*1
    Lost Communication with Drive Motor Control Module "A"

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0AA1-233 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.

  1. Turn the power switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


2.CHECK FREEZE FRAME DATA (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read the freeze frame data of DTC P0AA1-233.

    Result:

    Result
    Proceed to
    VH-Voltage after Boosting minus VL-Voltage before Boosting is 100 V or less.
    A
    The preceding condition is not satisfied.
    B

  1. Turn the power switch off.



B
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
A


3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


    A264189
  1. Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors (Click here).

    OK:
    The connectors are connected securely and there are no contact pressure problems.



OK
Go to step 5

NG
Go to step 4

4.CONNECT SECURELY

NEXT


5.CHECK CONNECTOR CONNECTION CONDITION (NO. 2 FLOOR WIRE CONNECTOR)
  1. Check the connector connections and contact pressure of the relevant terminals for the IO2 floor wire connector (Click here).

    OK:
    The connectors are connected securely and there are no contact pressure problems.



OK
Go to step 7

NG
Go to step 6

6.CONNECT SECURELY

NEXT


7.CHECK CONNECTOR CONNECTION CONDITION (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (IG), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 4 hybrid battery shield panel .



    A289040
  1. Check the connector connections and contact pressure of the relevant terminals for the hybrid battery junction block assembly connector (Click here).

    OK:
    The connector is connected securely and there are no contact pressure problems.

  1. Install the No. 4 hybrid battery shield panel.



OK
Go to step 9

NG
Go to step 8

8.CONNECT SECURELY

NEXT


9.CHECK GROUND WIRE CONNECTION CONDITION (SMR ACTIVATION LOW-VOLTAGE CIRCUIT)
  1. Check the installation condition of the ground wires I1, I2 and O1.

    OK:
    The ground wires I1, I2 and O1 are securely installed.



OK
Go to step 11

NG
Go to step 10

10.CONNECT SECURELY

NEXT


11.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (IG), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 4 hybrid battery shield panel .

  1. Disconnect the O9 hybrid battery junction block assembly connector.

  1. Disconnect the I3 power management control ECU connector.



    A260191E80
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    I3-4 (SMRB) - O9-1 (SMRB)
    Power switch off
    Below 1 Ω
    I3-2 (SMRG) - O9-3 (SMRG)
    Power switch off
    Below 1 Ω
    I3-3 (SMRP) - O9-4 (SMRP)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    I3-4 (SMRB) and O9-1 (SMRB) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    I3-2 (SMRG) and O9-3 (SMRG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    I3-3 (SMRP) and O9-4 (SMRP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Rear view of wire harness connector
    (to Hybrid Battery Junction Block Assembly)

  1. Reconnect the I3 power management control ECU connector.

  1. Reconnect the O9 hybrid battery junction block assembly connector.

  1. Install the No. 4 hybrid battery shield panel.



OK
Go to step 13

NG
Go to step 12

12.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT


13.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BODY GROUND)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (IG), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 4 hybrid battery shield panel .

  1. Disconnect the O9 hybrid battery junction block assembly connector.



    A259727E09
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    O9-2 (GND) - Body ground
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Hybrid Battery Junction Block Assembly)

  1. Reconnect the O9 hybrid battery junction block assembly connector.

  1. Install the No. 4 hybrid battery shield panel.



OK
Go to step 15

NG
Go to step 14

14.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT


15.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB, SMRG, SMRP)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (IG), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 4 hybrid battery shield panel .

  1. Disconnect the O9 hybrid battery junction block assembly connector.



    A259731E79
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    O9-1 (SMRB) - O9-2 (GND)
    -40 to 80 °C (-40 to 176°F)
    25.0 to 59.0 Ω
    O9-3 (SMRG) - O9-2 (GND)
    -40 to 80 °C (-40 to 176°F)
    25.0 to 59.0 Ω
    O9-4 (SMRP) - O9-2 (GND)
    -40 to 80 °C (-40 to 176°F)
    112 to 274 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Hybrid Battery Junction Block Assembly)

  1. Reconnect the O9 hybrid battery junction block assembly connector.

  1. Install the No. 4 hybrid battery shield panel.



OK
Go to step 17

NG
Go to step 16

16.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
(Click here)


NEXT
Go to step 19

17.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB, SMRG, SMRP)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (IG), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery shield sub-assembly .



    A266985E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (SMRB):
    Tester Connection
    Switch Condition
    Specified Condition
    Q2-1 (CBI) - A-1 (+)
    Power switch off
    10 kΩ or higher

    HINT:
    1. If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.
    2. If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.



    A266986E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (SMRG, SMRP):
    Tester Connection
    Switch Condition
    Specified Condition
    Q3-1 (CEI) - q1-1 (-)
    Power switch off
    10 kΩ or higher

    HINT:
    1. If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.
    2. If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
    3. If the resistance is between 28.5 and 31.5 Ω, it can be determined that SMRP is stuck closed.

  1. Install the No. 1 hybrid battery shield sub-assembly.


NEXT


18.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
(Click here)

NEXT


19.CHECK POWER MANAGEMENT CONTROL ECU (CHECK FOR NORMAL OPERATION)
  1. Install the service plug grip.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Clear the DTCs (Click here).

  1. Turn the power switch off and wait for 30 seconds or more.

  1. Turn the power switch on (READY).

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / Power Resource VB, VL-Voltage before Boosting.

  1. According to the display on the intelligent tester, read the Data List and monitor the values of "Power Resource VB" and "VL-Voltage before Boosting" for 3 minutes.

    Result:
    Result
    Proceed to
    Difference between "Power Resource VB" and "VL-Voltage before Boosting" is always less than 100 V.
    A
    Difference between "Power Resource VB" and "VL-Voltage before Boosting" is 100 V or more.
    B

  1. Turn the power switch off.



B
REPLACE POWER MANAGEMENT CONTROL ECU AND HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
A

END