AIR CONDITIONING SYSTEM > DETAILS |
| SYSTEM CONTROL |
The air conditioning system uses the following controls.
| Control | Function |
| Neural Network Control | This control is capable of performing complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship that is similar to a human brain. |
| Outlet Air Temperature Control | Based on the temperature set at the temperature control switch, the neural network control calculates the outlet air temperature based on the input signals from various sensors. |
| Left and Right Independent Control | The temperature setting for the driver and front passenger is controlled independently in order to provide a separate vehicle interior temperature for the right and left sides of the vehicle. Thus, air conditioning control that accommodates occupant preferences has been realized. |
| 3-zone Control*1 | The temperature setting for the driver, front passenger and rear passengers is controlled independently in order to provide 3 vehicle interior temperature zones, one each for the driver, front passenger and rear passengers. Thus, air conditioning control that accommodates occupant preferences has been realized. |
| Blower Control | Controls the blower motor in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors. |
| Air Outlet Control | Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control based on the input signals from various sensors. |
| In accordance with the engine coolant temperature, outside air temperature, amount of sunlight, required blower, outlet temperature, and vehicle speed conditions, this control automatically switches the blower outlet to FOOT/DEF mode to prevent the windows from becoming fogged when the outside air temperature is low. | |
| Air Inlet Control | Automatically controls the air inlet control damper to achieve the calculated outlet air temperature that is required. |
| Compressor Control | Through the calculation of the target evaporator temperature based on various sensor signals, the air conditioning amplifier assembly optimally controls the discharge capacity by regulating the opening extent of the solenoid valve. |
| The air conditioning amplifier assembly compares the pulley speed signals (transmitted by the lock sensor located on the compressor) with the engine speed signal (which are transmitted by the ECM (crankshaft position sensor)). When the air conditioning amplifier assembly determines that the pulley is locked, it turns off the magnetic clutch.*2 | |
| Refrigerant Shortage Detection Control | When the air conditioning is operating and the engine coolant temperature is above a specified value, the air conditioning amplifier assembly calculates the amount of refrigerant based on signals from the air conditioning pressure sensor, evaporator temperature sensor (No. 1 cooler thermistor) and outside temperature sensor (thermistor assembly). |
| Ion Generator Control*3 | The air conditioning amplifier assembly controls the ion generator assembly in accordance with the operation of the blower with fan motor sub-assembly. |
| Defroster Control | Defroster control logic is used to improve defroster performance. |
| Rear Window Defogger Control | When the rear defogger switch is pushed, the system is activated to keep the defogger heater on for approx. 15 minutes. However, the operating time of the rear defogger can be extended up to approx. 45 minutes when both of the following requirements are met:
|
| Fresh Air Introduction While Parking System | While parking, fresh air introduction mode is automatically selected. |
| Diagnosis | A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier assembly detects a problem with the air conditioning system. |
Neural Network Control
Previously, in automatic air conditioning systems without neural network control, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for performing a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly. The air conditioning amplifier assembly can then perform control in a way that provides enhanced air conditioning comfort.
The neural network control consists of neurons in the input layer, intermediate layer and output layer. The input layer neurons process the input data of the outside temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.

Fresh Air Introduction While Parking System
While parking, fresh air introduction mode is automatically selected to enhance ventilation and reduce any odor remaining in the air conditioning unit, thus odor during engine start-up is minimized.

| CONSTRUCTION |
Air Conditioning Control Assembly (Except TMMK Made Models)
A push-button type air conditioning control assembly is used.

| *A | LHD Models with Ion Generator Control | *B | RHD Models |
Air Conditioning Control Assembly (TMMK Made Models)
A push-button and dial type air conditioning control assembly is used for both automatic and manual air conditioning.
The air conditioning control assembly uses a Liquid Crystal Display (LCD).

Cooler Control Switch Assembly (Models with 3-zone Control)
A push-button type cooler control switch assembly is used for the rear seat.
Air Conditioning Radiator Assembly
The air conditioning radiator assembly consists of the evaporator, heater radiator unit sub-assembly, servo motors, evaporator temperature sensor (No. 1 cooler thermistor) and blower with fan motor sub-assembly.
A semi-center location air conditioning radiator assembly, in which the evaporator and heater radiator unit sub-assembly are placed in the vehicle's longitudinal direction. As a result, the air conditioning radiator assembly has been made compact and lightweight.

| *1 | Evaporator | *2 | Heater Radiator Unit Sub-assembly |
| *a | Side View | *b | Top View |
![]() | Front | - | - |
Evaporator
A Revolutionary super-Slim structure (RS) type evaporator is used.
Placing the tanks at the top and the bottom of the evaporator and adopting a micropore tube construction has provided the following benefits:

| *1 | Tank | *2 | Micropore Tube |
| *3 | Cooling Fin | - | - |
Evaporator Temperature Sensor (No. 1 Cooler Thermistor)
The evaporator temperature sensor (No. 1 cooler thermistor) detects the temperature of the cooled air immediately past the evaporator in the form of resistance changes, and outputs this data to the air conditioning amplifier assembly.
Heater Radiator Unit Sub-assembly
The compact, lightweight and highly efficient Straight Flow Aluminum (SFA)-II type heater radiator unit sub-assembly is used for the air conditioning system.

| *1 | Tank | - | - |
Blower with Fan Motor Sub-assembly
The blower with fan motor sub-assembly has a built-in blower controller which is controlled by the air conditioning amplifier assembly.
Air Conditioning Harness Assembly
An air conditioning harness assembly is used in the wire harness connection that connects the servo motor from the air conditioning amplifier assembly.

| *A | LHD Models without 3-zone Control | *B | LHD Models with 3-zone Control |
| *C | RHD Models | - | - |
| *1 | Bus Connector | *2 | Air Conditioning Harness Assembly |
| *a | To Air Conditioning Amplifier Assembly | *b | To Evaporator Temperature Sensor (No. 1 Cooler Thermistor) |
The air conditioning harness assembly has a built-in driver IC with a position detection function that communicates with each servo motor connector and actuates the servo motor. This enables bus communication for the servo motor wire harness with a more lightweight construction and a reduced number of wires.

| *A | Models with Bus Connector | *B | Models without Bus Connector |
| *1 | Air Conditioning Amplifier Assembly | *2 | Bus Connector |
| *3 | Communication Driver IC | *4 | Servo Motor |
| *5 | Communication IC | *6 | CPU |
| *7 | Driver IC | - | - |
Servo Motor
The pulse pattern type servo motor consists of a printed-circuit board and a servo motor. The printed-circuit board has 3 contact points, and can transmit 2 on-off signals to the air conditioning amplifier assembly based on the difference in the pulse phases. The bus connector can detect damper position and direction of movement with this signal.

Clean Air Filter
A high efficiency type filter is used. This filter is made of polyester and excels in the removal of dust and pollen. Because the filter is made of polyester it can be disposed of easily as a non-hazardous combustible material, a feature provided out of consideration for the environment.

| *1 | Clean Air Filter | *2 | Large Foreign Object Filter Layer |
| *3 | Electret Layer | *4 | Air Flow |
Cooler Condenser Assembly
The cooler condenser assembly consists of 2 cooling portions: a condensing portion and a super-cooling portion. These portions are integrated with a gas-liquid separator (modulator). This cooler condenser assembly uses a sub-cool cycle that offers excellent heat-exchange performance.
In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied state.
The desiccant and filter at the bottom of the modulator remove moisture and debris from the refrigerant.

| *1 | Gaseous Refrigerant | *2 | Condensing Portion |
| *3 | Modulator | *4 | Desiccant |
| *5 | Filter | *6 | Super-cooling Portion |
| *7 | Liquid Refrigerant | - | - |

Compressor
The compressor is a continuously variable capacity type air conditioning compressor. Its capacity can be varied in accordance with the cooling load of the air conditioning system.
The compressor consists of a pulley, shaft, lug plate, swash plate, piston, shoe, crank chamber, cylinder, air conditioning lock sensor (2GR-FE engine), solenoid valve with built-in Crank chamber to Suction passage (CS) valve, air conditioning mass flow sensor, oil separator and variable suction side throttle.
The oil separator consists of an oil separator chamber and an oil separator cylinder.

| *A | Models with 2AR-FE Engine or 6AR-FSE Engine | *B | Models with 2GR-FE Engine |
| *1 | Pulley | *2 | Magnetic Clutch Assembly |
| *3 | Air Conditioning Lock Sensor | *4 | Lug Plate |
| *5 | Crank Chamber | *6 | Shoe |
| *7 | Swash Plate | *8 | Piston |
| *9 | Cylinder | *10 | Solenoid Valve with Built-in CS Valve |
| *11 | Shaft | *12 | Air Conditioning Mass Flow Sensor |
| *13 | Oil Separator | *14 | Oil Separator Chamber |
| *15 | Oil Separator Cylinder | *16 | Variable Suction Side Throttle |
A plastic Damper and Limiter (DL) pulley and a steel pulley with magnetic clutch are present.
The plastic DL pulley contains a damper mechanism to absorb the torque fluctuations of the engine and a limiter mechanism to protect the drive belt in case the compressor locks. If the compressor locks, the limiter integrated into the pulley breaks, disconnecting the pulley from the compressor. To reduce weight, the pulley portion is made of plastic.
If the compressor locks, the steel with magnetic clutch pulley turns the magnetic clutch off to protect the drive belt and separates the pulley from the compressor.

| *A | Models with 2AR-FE Engine or 6AR-FSE Engine | *B | Models with 2GR-FE Engine |
| *1 | Plastic DL Pulley | *2 | Steel with Magnetic Clutch Pulley |
| *3 | Pulley Portion | *4 | Shaft |
| *5 | Damper | *6 | Limiter |
| *7 | Magnetic Clutch | - | - |
Cooler (Room Temp. Sensor) Thermistor
The cooler (room temp. sensor) thermistor detects the room temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.
Outside Temperature Sensor (Thermistor Assembly)
The outside temperature sensor (thermistor assembly) detects the outside temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.
Solar Sensor (Automatic Light Control Sensor)
The solar sensor (automatic light control sensor) consists of a photo diode, 2 amplifier circuits and a frequency conversion circuit.
The solar sensor (automatic light control sensor) detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight from its left and right sides (2 directions) and outputs these sunlight strength signals to the air conditioning amplifier assembly for the automatic air conditioning control.

Ion Generator Assembly (Models with Ion Generator Control)
The ion generator assembly is controlled by the air conditioning assembly and operates in accordance with the blower with fan motor sub-assembly.
The ion generator assembly emits "nanoe" ions that are electrically charged and encapsulated with water. The ions are discharged into the cabin through the driver side vent to provide skin-friendly clean air.*
*: According to temperature and humidity conditions, fan speed and air outlet mode selected, the ion generator assembly may not operate at full capacity.

| *1 | Ion Generator Assembly | - | - |
| *a | Common Negative Ion | *b | "nanoe" |
| *c | H2O | *d | Electron |
| OPERATION |
Mode Position and Door Operation
Air Conditioning Unit

| Control Damper | Operation Position | Door Position | Operation | |
| Air Inlet Control Damper | FRESH | A | Allows fresh air to enter. | |
| RECIRCULATION | B | Causes internal air to recirculate. | ||
| Air Mix Control Damper | MAX COLD to MAX HOT Temperature Setting | C - D - E (C' - D' - E') T - U - V | Varies the mixture ratio of the warm air and the cool air in order to regulate the temperature continuously between hot and cold. | |
| Mode Control Damper | ![]() | FACE | I, K, M, O, S, W | Air blows out of the front and rear center registers, and side registers. |
![]() | BI-LEVEL | I, K, N, O, R, X | Air blows out of the front and rear center registers, side register and front and rear footwell register ducts. | |
![]() | FOOT | H, J, L, P, Q, X | Air blows out of the front and rear footwell register ducts, and side registers. In addition, air blows out slightly from the center and side defrosters. | |
![]() | FOOT/DEF | G, J, L, P, Q, X | Defrosts the windshield through the center and side defrosters, side registers, and rear center register, while air is also blown out from the front and rear footwell register ducts. | |
![]() | DEF | F, J, L, P, S, Y | Defrosts the windshield through the center and side defrosters, and side registers. | |
Air Outlets and Airflow Volume

| MODE | Selection | Register | Footwell | Defroster | ||||
| AUTO | Manual | CTR | SIDE | RR | CTR | RR | ||
| A | B | C | D | E | F | |||
FACE![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
BI-LEVEL![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
FOOT-F*1![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
FOOT-R*2![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
FOOT-D*3![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
FOOT/DEF![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
DEF![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
Compressor Operation
Variable Capacity Operation



Air Conditioning Lock Sensor Operation (Models with 2GR-FE Engine)
Air Conditioning Mass Flow Sensor Operation

Oil Separator Operation

Variable Suction Side Throttle Operation

CS Valve Operation

| DIAGNOSIS |
The air conditioning amplifier assembly has a diagnosis function. It stores a record of any air conditioning system failures in its memory in the form of Diagnostic Trouble Codes (DTCs). For details, refer to the Repair Manual.