Item
| Abnormality Detection Condition
| Return Condition
| Master Warning Light
| Multi-information Display
|
Abnormal input voltage (High input voltage)
| Abnormal power source voltage (more than 17 V) is detected.
| Normal power source voltage (10 to 16 V) is detected.
| Flashes
| "Check Headlight System" is displayed
|
Abnormal input voltage (Low input voltage)*
| If the power source voltage is too low (8.5 to 10 V), LED output current will be limited. (Headlights will remain illuminated.)
| Output current limit is canceled when the voltage returns to the specified operation voltage (10 to 16 V).
| Flashes
| "Check Headlight System" is displayed
|
If the power source voltage is too low (7.1 to 8.5 V), headlight operation will stop.
| If the voltage returns to 8.5 V or more, headlight operation will resume.
|
Abnormal output
| - Open in output side circuit
- Short between output terminal and body ground
| Light control switch is turned off to head.
| Flashes
| "Check Headlight System" is displayed
|