SPIRAL CABLE (for TMC, TMMR Made) > INSPECTION |
| 1. INSPECT SPIRAL CABLE SUB-ASSEMBLY |
Remove the spiral cable with sensor sub-assembly from the vehicle (Click here).
Visually check for defects on the spiral cable sub-assembly.
The defects are as follows:
Check the spiral cable sub-assembly.

| *a | Component without harness connected (Spiral Cable Sub-assembly) | - | - |
![]() | Interlock | - | - |
Set the spiral cable sub-assembly to the center position .
Measure the resistance between each terminal of the spiral cable sub-assembly according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I28-1 (CCS) - z2-3 (CCS) | Always | 3 Ω or less |
| I28-2 (ECC) - z2-4 (ECC) | Always | 3 Ω or less |
| I28-3 (EAU) - z3-8 (EAU) | Always | 3 Ω or less |
| I28-4 (AU3) - z3-9 (AU3) | Always | 3 Ω or less |
| I28-5 (AU2) - z3-10 (AU2) | Always | 3 Ω or less |
| I28-6 (AU1) - z3-11 (AU1) | Always | 3 Ω or less |
| I28-9 (HO) - z3-1 (HO) | Always | 3 Ω or less |
| I28-10 (+DP) - z3-2 (+DP) | Always | 3 Ω or less |
| I28-11 (+DP2) - z3-3 (+DP2) | Always | 3 Ω or less |
| I28-13 (IL+2) - z3-5 (IL+2) | Always | 3 Ω or less |
| I27-1 (D+) - z4-2 (D+) | Always | Below 1 Ω |
| I27-2 (D-) - z4-1 (D-) | Always | Below 1 Ω |
After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise, and measure the resistance according to the value(s) in the table below. Then rotate the spiral cable sub-assembly 5 times counterclockwise, and measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I28-1 (CCS) - z2-3 (CCS) | Always | 3 Ω or less |
| I28-2 (ECC) - z2-4 (ECC) | Always | 3 Ω or less |
| I28-3 (EAU) - z3-8 (EAU) | Always | 3 Ω or less |
| I28-4 (AU3) - z3-9 (AU3) | Always | 3 Ω or less |
| I28-5 (AU2) - z3-10 (AU2) | Always | 3 Ω or less |
| I28-6 (AU1) - z3-11 (AU1) | Always | 3 Ω or less |
| I28-9 (HO) - z3-1 (HO) | Always | 3 Ω or less |
| I28-10 (+DP) - z3-2 (+DP) | Always | 3 Ω or less |
| I28-11 (+DP2) - z3-3 (+DP2) | Always | 3 Ω or less |
| I28-13 (IL+2) - z3-5 (IL+2) | Always | 3 Ω or less |
| I27-1 (D+) - z4-2 (D+) | Always | Below 1 Ω |
| I27-2 (D-) - z4-1 (D-) | Always | Below 1 Ω |
After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise. Then while rotating the spiral cable sub-assembly 5 times counterclockwise, measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I28-1 (CCS) - z2-3 (CCS) | Always | 3 Ω or less |
| I28-2 (ECC) - z2-4 (ECC) | Always | 3 Ω or less |
| I28-3 (EAU) - z3-8 (EAU) | Always | 3 Ω or less |
| I28-4 (AU3) - z3-9 (AU3) | Always | 3 Ω or less |
| I28-5 (AU2) - z3-10 (AU2) | Always | 3 Ω or less |
| I28-6 (AU1) - z3-11 (AU1) | Always | 3 Ω or less |
| I28-9 (HO) - z3-1 (HO) | Always | 3 Ω or less |
| I28-10 (+DP) - z3-2 (+DP) | Always | 3 Ω or less |
| I28-11 (+DP2) - z3-3 (+DP2) | Always | 3 Ω or less |
| I28-13 (IL+2) - z3-5 (IL+2) | Always | 3 Ω or less |
| I27-1 (D+) - z4-2 (D+) | Always | Below 1 Ω |
| I27-2 (D-) - z4-1 (D-) | Always | Below 1 Ω |