Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › SPIRAL CABLE (for TMMK Made)

SPIRAL CABLE (for TMMK Made) > INSPECTION

for Preparation Click here



1. INSPECT SPIRAL CABLE WITH SENSOR SUB-ASSEMBLY
  1. Visually check for defects on the spiral cable with sensor sub-assembly.

    1. The defects are as follows:

      1. Scratches
      2. Small cracks
      3. Dents
      4. Chips
      5. Cracks or other damage to the connector

        OK:
        No defects are found.

      If any of the defects is found, replace the spiral cable with sensor sub-assembly with a new one.



  1. Check the spiral cable with sensor sub-assembly.


    C286213E05


    Text in Illustration 
    *a
    Component without harness connected
    (Spiral Cable with Sensor Sub-assembly)
    *b
    Color: Orange
    *c
    Color: Black
    -
    -
    V100144
    Interlock
    -
    -

    NOTICE:
    1. When rotating the spiral cable with sensor sub-assembly, make sure to push on the interlock indicated in the illustration to release the interlock mechanism.
    2. As the spiral cable with sensor sub-assembly may break, do not rotate the spiral cable with sensor sub-assembly more than the specified amount.


    1. Set the spiral cable with sensor sub-assembly to the center position .

    2. Measure the resistance between each terminal of the spiral cable with sensor sub-assembly according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      I28-1 (CCS) - z2-3 (CCS)
      Always
      3 Ω or less
      I28-2 (ECC) - z2-4 (ECC)
      Always
      3 Ω or less
      I28-3 (EAU) - z3-8 (EAU)
      Always
      3 Ω or less
      I28-4 (AU3) - z3-9 (AU3)
      Always
      3 Ω or less
      I28-5 (AU2) - z3-10 (AU2)
      Always
      3 Ω or less
      I28-6 (AU1) - z3-11 (AU1)
      Always
      3 Ω or less
      I28-7 (SDN) - z3-12 (SDN)
      Always
      3 Ω or less
      I28-9 (HO) - z3-1 (HO)
      Always
      3 Ω or less
      I28-10 (+DP) - z3-2 (+DP)
      Always
      3 Ω or less
      I28-11 (+DP2) - z3-3 (+DP2)
      Always
      3 Ω or less
      I28-13 (IL+2) - z3-5 (IL+2)
      Always
      3 Ω or less
      I28-14 (SUP) - z3-6 (SUP)
      Always
      3 Ω or less
      I27-1 (D+) - z4-2 (D+)
      Always
      Below 1 Ω
      I27-2 (D-) - z4-1 (D-)
      Always
      Below 1 Ω
      I27-3 (D2-) - z5-1 (D2-)
      Always
      Below 1 Ω
      I27-4 (D2+) - z5-2 (D2+)
      Always
      Below 1 Ω

    3. After setting the spiral cable with sensor sub-assembly to the center position, rotate the spiral cable with sensor sub-assembly 2.5 times clockwise, and measure the resistance according to the value(s) in the table below. Then rotate the spiral cable with sensor sub-assembly 5 times counterclockwise, and measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      I28-1 (CCS) - z2-3 (CCS)
      Always
      3 Ω or less
      I28-2 (ECC) - z2-4 (ECC)
      Always
      3 Ω or less
      I28-3 (EAU) - z3-8 (EAU)
      Always
      3 Ω or less
      I28-4 (AU3) - z3-9 (AU3)
      Always
      3 Ω or less
      I28-5 (AU2) - z3-10 (AU2)
      Always
      3 Ω or less
      I28-6 (AU1) - z3-11 (AU1)
      Always
      3 Ω or less
      I28-7 (SDN) - z3-12 (SDN)
      Always
      3 Ω or less
      I28-9 (HO) - z3-1 (HO)
      Always
      3 Ω or less
      I28-10 (+DP) - z3-2 (+DP)
      Always
      3 Ω or less
      I28-11 (+DP2) - z3-3 (+DP2)
      Always
      3 Ω or less
      I28-13 (IL+2) - z3-5 (IL+2)
      Always
      3 Ω or less
      I28-14 (SUP) - z3-6 (SUP)
      Always
      3 Ω or less
      I27-1 (D+) - z4-2 (D+)
      Always
      Below 1 Ω
      I27-2 (D-) - z4-1 (D-)
      Always
      Below 1 Ω
      I27-3 (D2-) - z5-1 (D2-)
      Always
      Below 1 Ω
      I27-4 (D2+) - z5-2 (D2+)
      Always
      Below 1 Ω

    4. After setting the spiral cable with sensor sub-assembly to the center position, rotate the spiral cable with sensor sub-assembly 2.5 times clockwise. Then while rotating the spiral cable with sensor sub-assembly 5 times counterclockwise, measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      I28-1 (CCS) - z2-3 (CCS)
      Always
      3 Ω or less
      I28-2 (ECC) - z2-4 (ECC)
      Always
      3 Ω or less
      I28-3 (EAU) - z3-8 (EAU)
      Always
      3 Ω or less
      I28-4 (AU3) - z3-9 (AU3)
      Always
      3 Ω or less
      I28-5 (AU2) - z3-10 (AU2)
      Always
      3 Ω or less
      I28-6 (AU1) - z3-11 (AU1)
      Always
      3 Ω or less
      I28-7 (SDN) - z3-12 (SDN)
      Always
      3 Ω or less
      I28-9 (HO) - z3-1 (HO)
      Always
      3 Ω or less
      I28-10 (+DP) - z3-2 (+DP)
      Always
      3 Ω or less
      I28-11 (+DP2) - z3-3 (+DP2)
      Always
      3 Ω or less
      I28-13 (IL+2) - z3-5 (IL+2)
      Always
      3 Ω or less
      I28-14 (SUP) - z3-6 (SUP)
      Always
      3 Ω or less
      I27-1 (D+) - z4-2 (D+)
      Always
      Below 1 Ω
      I27-2 (D-) - z4-1 (D-)
      Always
      Below 1 Ω
      I27-3 (D2-) - z5-1 (D2-)
      Always
      Below 1 Ω
      I27-4 (D2+) - z5-2 (D2+)
      Always
      Below 1 Ω

      If the result is not as specified, replace the spiral cable with sensor sub-assembly.