STARTER > REASSEMBLY |
| 1. INSTALL PLANETARY GEAR |
![]() |
Apply high-temperature grease to the 3 planetary gears, 3 planetary gear shafts and No. 2 repair service starter kit.
![]() | High-temperature Grease |
Install the 3 planetary gears to the No. 2 repair service starter kit.
| 2. INSTALL STARTER ARMATURE ASSEMBLY |
![]() |
Apply high-temperature grease to the starter armature shaft.
![]() | High-temperature Grease |
![]() |
Apply high-temperature grease to the washer and bearing shown in the illustration.
| *1 | Washer |
| *a | Bearing |
![]() | High-temperature Grease |
Install the starter armature assembly to the starter commutator end frame assembly.
![]() |
Using snap ring pliers, install the washer and a new snap ring.
| *a | Snap Ring Pliers |
![]() |
Using a vernier caliper, measure the width of the snap ring end gap as shown in the illustration.
| *a | Width |
| 3. INSTALL STARTER COMMUTATOR END FRAME COVER |
![]() |
Install the starter commutator end frame cover to the starter commutator end frame assembly.
| 4. INSTALL STARTER ARMATURE PLATE |
![]() |
Insert the starter armature plate to the starter yoke assembly.
| *a | Keyway |
| *b | Key |
Align the keyway of the starter armature plate with the key inside the starter yoke assembly, and install the starter armature plate.
| 5. INSTALL STARTER COMMUTATOR END FRAME ASSEMBLY |
![]() |
Align the rubber of the starter commutator end frame assembly with the cutout of the starter yoke assembly.
| *a | Cutout |
| *b | Rubber |
Install the starter commutator end frame assembly to the starter yoke assembly.
| 6. INSTALL STARTER YOKE ASSEMBLY |
![]() |
Align the protrusion of the starter yoke assembly with the cutout of the No. 2 repair service starter kit.
| *a | Cutout |
| *b | Protrusion |
Install the starter yoke assembly with the 2 through bolts.
| 7. INSTALL REPAIR SERVICE STARTER KIT |
![]() |
Apply high-temperature grease to the plunger.
| *a | Hook |
![]() | High-temperature Grease |
Hang the hook of the plunger on the drive lever.
Apply high-temperature grease to the return spring.
Install the return spring to the plunger.
Install the magnet switch to the No. 2 repair service starter kit with the 2 screws.
Connect the field coil lead wire to terminal C with the nut.