POWER WINDOW CONTROL SYSTEM (for Models with Jam Protection Function on 4 Windows) > INITIALIZATION |
| INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR MOTOR ASSEMBLY (ALL DOORS)) (EXCEPT TMMR MADE) |
Perform initialization according to the table below.
| Condition of Power Window | Proceed to |
| Initialization method when a power window regulator motor assembly has been replaced with a new one. | Procedure A |
Initialization method when a power window regulator motor assembly has been removed/installed or a door glass and/or door glass run etc. have been removed/installed or replaced with new ones.
| Procedure B |
| Initialization method when a reverse rotation malfunction occurs due to a sliding resistance change resulting from adjustment etc. | Procedure C |
Procedure A
Connect the battery and turn the ignition switch ON.
Fully open the power window by fully pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the power window is fully closed to reset the glass position and complete initialization.
Procedure B
Connect the battery and turn the ignition switch to ON.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway even when the switch is fully pulled up, release the switch and fully pull it again).
Fully open the window by pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Release the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly. Then fully push down and hold the switch for 4 seconds or more.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.
Procedure C
Connect the battery and turn the ignition switch to ON.
Fully open the window by fully pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.
| INITIALIZE POWER WINDOW CONTROL SYSTEM (ALL DOORS) (FOR TMMR MADE) |
Perform initialization according to the table below.
| Condition of Power Window | Proceed to |
| Initialization method when a power window regulator motor assembly has been replaced with a new one. | Procedure A |
| Procedure B |
| Initialization method for when the power window unexpectedly operates in reverse or stops due to a change in the sliding resistance after a fitting adjustment is made. | Procedure C |
Procedure A
Perform registration of the door glass position (fully closed, fully open) and sliding resistance learning.

Procedure B
Reset the door glass position, perform window position initialization (fully closed, fully open) and sliding resistance learning.


Procedure C
Perform sliding resistance learning.