OUTER MIRROR SWITCH > INSPECTION |
| 1. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/o Memory) |
Check the mirror select switch and mirror surface adjust switch. (except TMMK Made)
![]() |
Turn the mirror select switch to the L position.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 4 (MLV) - 8 (B) 6 (M+) - 7 (E) | UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 4 (MLV) - 7 (E) 6 (M+) - 8 (B) | DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 5 (MLH) - 8 (B) 6 (M+) - 7 (E) | LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 5 (MLH) - 7 (E) 6 (M+) - 8 (B) | RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
Turn the mirror select switch to the R position.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (MRV) - 8 (B) 6 (M+) - 7 (E) | UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 3 (MRV) - 7 (E) 6 (M+) - 8 (B) | DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 2 (MRH) - 8 (B) 6 (M+) - 7 (E) | LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 2 (MRH) - 7 (E) 6 (M+) - 8 (B) | RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
| *1 | Mirror select switch |
| *2 | Mirror surface adjust switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
Check the mirror retract switch. (except TMMK Made)
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 10 (MF) - 7 (E) | Mirror retract switch retract position | Below 1 Ω |
| 9 (MR) - 8 (B) | Below 1 Ω | |
| 10 (MF) - 8 (B) | Mirror retract switch return position | Below 1 Ω |
| 9 (MR) - 7 (E) | Below 1 Ω |
| *1 | Mirror retract switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
Check the mirror select switch and mirror surface adjust switch. (for TMMK Made)
![]() |
Turn the mirror select switch to the L position.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 15 (VL) - 19 (B) 17 (M+) - 18 (E) | UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 15 (VL) - 18 (E) 17 (M+) - 19 (B) | DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 16 (HL) - 19 (B) 17 (M+) - 18 (E) | LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 16 (HL) - 18 (E) 17 (M+) - 19 (B) | RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
Turn the mirror select switch to the R position.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 14 (VR) - 19 (B) 17 (M+) - 18 (E) | UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 14 (VR) - 18 (E) 17 (M+) - 19 (B) | DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 13 (HR) - 19 (B) 17 (M+) - 18 (E) | LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 13 (HR) - 18 (E) 17 (M+) - 19 (B) | RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
| *1 | Mirror select switch |
| *2 | Mirror surface adjust switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
Check the mirror retract switch. (for TMMK Made)
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 21 (MF) - 18 (E) | Mirror retract switch retract position | Below 1 Ω |
| 20 (MR) - 19 (B) | Below 1 Ω | |
| 21 (MF) - 19 (B) | Mirror retract switch return position | Below 1 Ω |
| 20 (MR) - 18 (E) | Below 1 Ω |
| *1 | Mirror retract switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
| 2. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Memory) |
![]() |
Check the switch functions.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (M+) - 2 (E1) | Mirror adjust switch pressed up | 90 to 110 Ω |
| Mirror adjust switch pressed down | 437 to 503 Ω | |
| Mirror adjust switch pressed left | 744 to 856 Ω | |
| Mirror adjust switch pressed right | 225 to 275 Ω | |
| Mirror adjust switch not pressed | 10 kΩ or higher | |
| 1 (MSW) - 2 (E1) | Mirror select switch R | Below 1 Ω |
| Mirror select switch L | 90 to 110 Ω | |
| Mirror select switch off | 10 kΩ or higher |
| *1 | Mirror Adjust Switch |
| *2 | Mirror Select Switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
Check the mirror retract switch.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 8 (MF) - 4 (E2) | Mirror retract switch retract position | Below 1 Ω |
| 7 (MR) - 6 (B) | Below 1 Ω | |
| 8 (MF) - 6 (B) | Mirror retract switch return position | Below 1 Ω |
| 7 (MR) - 4 (E2) | Below 1 Ω | |
| 7 (MR) - 8 (MF) | Always | 10 kΩ or higher |
| *1 | Mirror retract switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |