CHARGING SYSTEM > ON-VEHICLE INSPECTION |
| 1. CHECK BATTERY CONDITION |
Check the battery for damage or deformation. If severe damage, deformation or leakage is found, replace the battery.
Check the electrolyte level in each cell.
For maintenance-free batteries:
For non-maintenance-free batteries:
Check the voltage.
Turn the ignition switch off and turn on the headlights for 20 to 30 seconds. This will remove the surface charge from the battery.
Measure the battery voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Positive (+) terminal - Negative (-) terminal | 20°C (68°F) | 12.6 to 12.8 V |
| 2. CHECK BATTERY TERMINAL |
Check that the battery terminals are not loose or corroded.
If a terminal is loose or corroded, tighten or clean the terminal.
| 3. CHECK FUSES |
Measure the resistance of each fuse for the charging system.
| 4. INSPECT V-RIBBED BELT |
![]() |
Check the V-ribbed belt for wear, cracks or other signs of damage.
If any of the following defects is found, replace the V-ribbed belt.
![]() |
Check that the V-ribbed belt fits properly in the ribbed grooves.
| *a | Correct |
| *b | Incorrect |
| 5. INSPECT GENERATOR WIRING |
Visually check the generator wiring.
Check that the wiring is in good condition.
| 6. CHECK FOR ABNORMAL NOISE |
Check for abnormal noises from the generator assembly.
Check that no abnormal noises are heard from the generator assembly while the engine is running.
If noise occurs, refer to Problem Symptoms Table (Click here).
| 7. INSPECT CHARGE WARNING LIGHT CIRCUIT |
Turn the ignition switch to ON. Check that the charge warning light comes on.
Start the engine and check that the charge warning light goes off.
If the light does not operate as specified, perform troubleshooting of the charge warning light (Click here).
| 8. INSPECT CHARGING CIRCUIT WITHOUT LOAD |
![]() |
Connect a voltmeter and an ammeter to the charging circuit as follows.
| *1 | Generator Assembly |
| *2 | Battery |
| *a | Terminal B |
Disconnect the wire from terminal B of the generator assembly and connect it to the negative (-) lead of the ammeter.
Connect the ammeter positive (+) lead to terminal B of the generator assembly.
Connect the voltmeter positive (+) lead to the positive (+) terminal of the battery.
Ground the voltmeter negative (-) lead.
Check the charging circuit.
Maintain the engine speed at 2000 rpm and check the readings on the ammeter and voltmeter.
| 9. INSPECT CHARGING CIRCUIT WITH LOAD |
With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the "HI" position.
Check the reading on the ammeter.