INTEGRATION RELAY > INSPECTION |
| 1. INSPECT NO. 1 INTEGRATION RELAY |

| *1 | No. 1 Integration Relay | - | - |
EFI MAIN RELAY:
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| No. 1 integration relay 1B-1 - No. 1 integration relay 1A-8 | Battery voltage is not applied between terminals 1C-7 and 1E-2 | 10 kΩ or higher |
| No. 1 integration relay 1B-1 - No. 1 integration relay 1A-8 | Battery voltage is applied between terminals 1C-7 and 1E-2 | Below 1 Ω |
| No. 1 integration relay 1B-1 - No. 1 integration relay 1C-3 | ||
| No. 1 integration relay 1B-1 - No. 1 integration relay 1C-4 | ||
| No. 1 integration relay 1B-1 - No. 1 integration relay 1C-6 | ||
| No. 1 integration relay 1B-1 - No. 1 integration relay 1C-9 | ||
| No. 1 integration relay 1B-1 - No. 1 integration relay 1C-10 |
| *1 | No. 1 Integration Relay |
A/F HTR RELAY:
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| No. 1 integration relay 1A-6 - No. 1 integration relay 1D-1 | Battery voltage is not applied between terminals 1A-8 and 1E-2 | 10 kΩ or higher |
| No. 1 integration relay 1A-6 - No. 1 integration relay 1D-1 | Battery voltage is applied between terminals 1A-8 and 1E-2 | Below 1 Ω |
| No. 1 integration relay 1A-7 - No. 1 integration relay 1D-1 |
| *1 | No. 1 Integration Relay |
IG2 RELAY:
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| No. 1 integration relay 1A-1 - No. 1 integration relay 1D-3 | Battery voltage is not applied between terminals 1C-8 and 1E-2 | 10 kΩ or higher |
| No. 1 integration relay 1A-1 - No. 1 integration relay 1D-3 | Battery voltage is applied between terminals 1C-8 and 1E-2 | Below 1 Ω |
| No. 1 integration relay 1A-3 - No. 1 integration relay 1D-3 | ||
| No. 1 integration relay 1A-5 - No. 1 integration relay 1D-3 | ||
| No. 1 integration relay 1C-1 - No. 1 integration relay 1D-3 | ||
| No. 1 integration relay 1C-2 - No. 1 integration relay 1D-3 | ||
| No. 1 integration relay 1C-5 - No. 1 integration relay 1D-3 |
| *1 | No. 1 Integration Relay |