Home › Engine / Hybrid System · 6AR-FSE › STARTING › RELAY

RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT ST RELAY


    E209082
  1. Check the resistance.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      3 - 5
      Battery voltage not applied to terminals 1 and 2
      10 kΩ or higher
      Battery voltage applied to terminals 1 and 2
      Below 1 Ω

      If the result is not as specified, replace the ST relay.