AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor (cooler thermistor) / Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) | Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Ambient temperature sensor (thermistor assembly) / Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) | - | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor (No. 1 cooler thermistor) / Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) | Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Driver side automatic light control sensor (solar sensor) / Min.: 0 Max.: 255 | Driver side automatic light control sensor (solar sensor) value increases as brightness increases | - |
| Solar Sensor (P Side) | Front passenger side automatic light control sensor (solar sensor) / Min.: 0 Max.: 255 | Front passenger side automatic light control sensor (solar sensor) value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature sensor / Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature displayed | - |
| Set Temperature (D Side) | Driver side set temperature / Min.: MAX COLD Max.: MAX HOT | Driver side set temperature displayed | - |
| Set Temperature (P Side) | Front passenger side set temperature / Min.: MAX COLD Max.: MAX HOT | Front passenger side set temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 Max.: 31 | Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioning pressure sensor / Min.: -0.4566 MPaG Max.: 3.2943 MPaG | Actual refrigerant pressure displayed | - |
| Regulator Control Current | Solenoid valve control current / Min.: 0 A Max.: 0.997 A | Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| Set Temperature (Rear)*3 | Rear set temperature / Min.: MAX COLD Max.: MAX HOT | Actual rear set temperature displayed | - |
| Air Mix Servo Targ Pulse(R)*3 | No. 3 air conditioning radiator damper servo sub-assembly (rear air mix) target pulse / Min.: 0 Max.: 255 | MAX. COLD: 113 (pulse) MAX. HOT: 29 (pulse) | - |
| Air Mix Servo Actual Pulse(R)*3 | No. 3 air conditioning radiator damper servo sub-assembly (rear air mix) actual pulse / Min.: 0 Max.: 255 | MAX. COLD: 113 (pulse) MAX. HOT: 29 (pulse) | - |
| Air Mix Servo Targ Pulse(D) | for LHD: No. 2 air conditioning radiator damper servo sub-assembly (air mix*1) target pulse / Min.: 0 Max.: 255 for RHD: No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) target pulse / Min.: 0 Max.: 255 | for LHD: MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) for RHD: MAX. COLD: 105 MAX. HOT: 7 | - |
| Air Mix Servo Actual Pulse(D) | for LHD: No. 2 air conditioning radiator damper servo sub-assembly (air mix*1) actual pulse / Min.: 0 Max.: 255 for RHD: No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) actual pulse / Min.: 0 Max.: 255 | for LHD: MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) for RHD: MAX. COLD: 105 MAX. HOT: 7 | - |
| Air Mix Servo Targ Pulse(P) | for LHD: No. 1 air conditioning radiator damper servo sub-assembly (air mix*2) target pulse / Min.: 0 Max.: 255 for RHD: No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) target pulse / Min.: 0 Max.: 255 | for LHD: MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) for RHD: MAX. COLD: 5 MAX. HOT: 103 | - |
| Air Mix Servo Actual Pulse(P) | for LHD: No. 1 air conditioning radiator damper servo sub-assembly (air mix*2) actual pulse / Min.: 0 Max.: 255 for RHD: No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) actual pulse / Min.: 0 Max.: 255 | for LHD: MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) for RHD: MAX. COLD: 5 MAX. HOT: 103 | - |
| Air Outlet Servo Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse / Min.: 0 Max.: 255 | FACE: 8 (pulse) B/L: 30 (pulse) FOOT (Manual mode) : 67 (pulse) FOOT (Automatic mode) : 60, 67 or 74 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) | - |
| Air Outlet Servo Actu Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse / Min.: 0 Max.: 255 | FACE: 8 (pulse) B/L: 30 (pulse) FOOT (Manual mode) : 67 (pulse) FOOT (Automatic mode) : 60, 67 or 74 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) | - |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (air inlet) target pulse / Min.: 0 Max.: 255 | RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) | - |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly (air inlet) actual pulse / Min.: 0 Max.: 255 | RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) | - |
| Electric Heater Control*4 | Maximum heater operation level / Min.: 0 Max.: 2 | Maximum possible operation level of quick heater assembly displayed | - |
| Electric Heater Active Level*4 | Actual heater operation level / Min.: 0 Max.: 2 | Actual operation level of quick heater assembly displayed | - |
| Shift Set Temperature | Shift set temperature / 2C decr, 1C decr, Normal, 1C incr, 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode / Auto or Manual | Customized value displayed | - |
| Compressor Mode | Compressor mode / Auto or Manual | Customized value displayed | - |
| Evaporator Control | Evaporator control / Auto or Manual | Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check / ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control / Slow, Normal, Fast | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/DEF auto mode / ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/DEF auto blower speed increase / ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr | Customized value displayed | - |
| Flow Sensor | A/C flow sensor / Min.: 0 V Max.: 5 V | Ignition switch ON: 0.3 to 4.7 V | A/C flow sensor is malfunctioning when a constant value below 0.3 V or higher than 4.7 V is displayed continuously for more than 4 seconds. |
| A/C Cutoff Signal | A/C control cutoff signal / OFF or ON | A/C switch on: OFF A/C switch off: ON | - |
| Ion Generate Control*5 | Ion generator control / ON or OFF | Customized value displayed | - |
| Outside Air Mode Auto Switch Function | Number of trouble codes / Min.: 0 Max.: 255 | Number of DTCs displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0 Max.: 255 | Number of DTCs displayed | - |
| ACTIVE TEST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
Perform the Active Test according to the display on the intelligent tester.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0, Max.: 31 | - |
| Magnetic Clutch Relay | A/C system operation | OFF, ON | - |
| Defogger Relay (Rear) | Defogger relay (engine room junction block assembly) | OFF, ON | - |
| Heater Active Level*4 | Quick heater assembly | Min.: 0, Max.: 2 | - |
| Air Mix Servo Targ Pulse(D) | for LHD: No. 2 air conditioning radiator damper servo sub-assembly (air mix*1) pulse for RHD: No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) pulse | Min.: 0, Max.: 255 | for LHD: Operates between 5 and 103 pulses for RHD: Operates between 7 and 105 pulses |
| Air Mix Servo Targ Pulse(P) | for LHD: No. 1 air conditioning radiator damper servo sub-assembly (air mix*2) pulse for RHD: No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) pulse | Min.: 0, Max.: 255 | for LHD: Operates between 7 and 105 pulses for RHD: Operates between 5 and 103 pulses |
| Air Outlet Servo Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse | Min.: 0, Max.: 255 | Operates between 8 and 97 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (air inlet) pulse | Min.: 0, Max.: 255 | Operates between 7 and 28 pulses |
| Rear Air Mix Servo Targ Pulse*3 | No. 3 air conditioning radiator damper servo sub-assembly (rear air mix) pulse | Min.: 0, Max.: 255 | Operates between 29 and 113 pulses |
| Ion Generator*5 | Ion generator sub-assembly | OFF, ON | - |