BLOWER UNIT (for TMC, TMMR Made) > REMOVAL |
| 1. REMOVE AIR CONDITIONING UNIT ASSEMBLY |
| 2. REMOVE NO. 1 AIR DUCT SUB-ASSEMBLY |
![]() |
Disengage the 2 claws and guide, and remove the No. 1 air duct sub-assembly as shown in the illustration.
| 3. REMOVE NO. 6 HEATER TO REGISTER DUCT ASSEMBLY |
![]() |
Disengage the 2 claws and 2 guides, and remove the No. 6 heater to register duct assembly as shown in the illustration.
| 4. REMOVE AIR CONDITIONING HARNESS ASSEMBLY (for Dual Type) |
![]() |
Remove the heater packing as shown in the illustration.
![]() |
Disconnect the 5 connectors.
Disengage 7 clamps and remove the air conditioning harness assembly.
| 5. REMOVE AIR CONDITIONING HARNESS ASSEMBLY (for 3 Zone Type) |
![]() |
Remove the heater packing as shown in the illustration.
![]() |
Disconnect the 6 connectors.
Disengage 7 clamps and remove the air conditioning harness assembly.
| 6. REMOVE BLOWER ASSEMBLY |
![]() |
Remove the 2 screws.
Disengage the 2 claws and remove the blower assembly.