Home › Power Source / Network ยท 2AR-FE BATTERY / CHARGING › CHARGING SYSTEM

CHARGING SYSTEM > Charge Warning Light Comes ON while Driving

for Preparation Click here


INSPECTION PROCEDURE

1.CHECK LOCK FUNCTION OF GENERATOR PULLEY WITH CLUTCH
  1. Check the lock function with the pulley installed in the vehicle.

    1. Visually check that the rotor in the generator operates with the engine started.



  1. Check the lock function with the pulley removed from the vehicle.

    1. Remove the generator pulley cap.



    2. A208964E03
    3. Hold the generator rotor using SST, and turn the generator pulley with clutch clockwise to check that the outer ring locks.
      Text in Illustration 
      *a
      Free
      *b
      Lock

      OK:
      The outer ring locks.

      Result:
      Result
      Proceed to
      OK
      A
      NG (for 100 A, 130 A)
      B
      NG (for 150 A)
      C

SST
09820-63021  


B
REPLACE GENERATOR PULLEY WITH CLUTCH (Click here)

C
REPLACE GENERATOR PULLEY WITH CLUTCH (Click here)
A


2.CHECK LOCK OF GENERATOR PULLEY WITH CLUTCH
  1. Start the engine and visually check for looseness of the generator pulley with clutch.

    OK:
    The generator pulley with clutch is not loose.

    Result:
    Result
    Proceed to
    OK (for 100, 130 A)
    A
    OK (for 1150 A)
    B
    NG (for 100 A, 130 A)
    C
    NG (for 150 A)
    D



B
REPLACE GENERATOR ASSEMBLY (Click here)

C
TIGHTEN GENERATOR PULLEY WITH CLUTCH TO THE SPECIFIED TORQUE

D
TIGHTEN GENERATOR PULLEY WITH CLUTCH TO THE SPECIFIED TORQUE
A