Home › Engine / Hybrid System · 2GR-FE › INTAKE / EXHAUST › VACUUM SWITCHING VALVE (for Intake Air Control System)

VACUUM SWITCHING VALVE (for Intake Air Control System) > INSPECTION

for Preparation Click here



1. INSPECT VACUUM SWITCHING VALVE
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    37 to 44 Ω
    1 - Valve body
    Always
    10 kΩ or higher
    2 - Valve body

    If the result is not as specified, replace the vacuum switching valve.



    A254377E01
  1. Using a vacuum pump, check that air flows through the vacuum switching valve as specified.

    OK:
    Measurement Condition
    Specified Condition
    Battery voltage applied between terminals 1 and 2 and vacuum applied to port F.
    Air is sucked into port E.
    Battery voltage not applied between terminals 1 and 2 and vacuum applied to port E.
    Air is sucked into filter.

    Text in Illustration 
    *1
    Filter
    If the result is not as specified, replace the vacuum switching valve.