Home › General › SPECIFICATIONS › 2AR-FE BATTERY / CHARGING

2AR-FE BATTERY / CHARGING > SERVICE DATA



Battery
Standard voltage
12.5 to 12.9 V at 20°C (68°F)
Charging circuit without load
Standard amperage
10 A or less
Standard voltage
13.2 to 14.8 V
Charging circuit with load
Standard amperage
30 A or more
Generator brush holder assembly
Brush length
Standard length
9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum length
4.5 mm (0.177 in.)
for 100, 130 A Type
Generator rotor assembly
Standard resistance
Slip ring
1.8 to 2.2 Ω at 20°C (68°F) (for 100 A Type)
1.55 to 1.95Ω at 20°C (68°F) (for 130 A Type)
Slip ring - Rotor
10 kΩ or higher
Slip ring diameter
Standard diameter
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter
14 mm (0.551 in.)
for 150 A Type
Generator rotor assembly
Standard resistance
Slip ring
1.5 to 1.9 Ω at 20°C (68°F)
Slip ring - Rotor
10 kΩ or higher
Slip ring diameter
Standard diameter
14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter
14 mm (0.551 in.)