CANISTER > INSPECTION |
| 1. INSPECT CANISTER (CHARCOAL CANISTER ASSEMBLY) |
Visually check the canister (charcoal canister assembly).
Visually check the canister (charcoal canister assembly) for cracks or damage.
If cracks or damage are found, replace the canister (charcoal canister assembly).
Check canister (charcoal canister assembly) air flow.
![]() |
Using a vacuum pump, check that air flows through the canister (charcoal canister assembly) according to the table below.
| *a | Port (A) |
| *b | Port (B) |
| *c | Port (C) |
| Condition | Specified Condition |
| Block port (B) and (C) and apply 2 kPa (15 mmHg, 0.591 in. Hg) of vacuum into port (A) | There are no leaks |
| Block port (B) and apply 2 kPa (15 mmHg, 0.591 in. Hg) of vacuum into port (A) | Air is sucked into port (C) |
| Block port (C) and blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into port (A) | Air comes out of port (B) |
| Blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into port (A) | Air comes out of port (B) and (C) |
| 2. CLEAN FILTER IN CANISTER (CHARCOAL CANISTER ASSEMBLY) |
![]() |
Clean the filter by blowing 5 kPa (0.1 kgf/cm2, 0.7 psi) of compressed air into the port (A) while holding the port (B) closed.
| *a | Port (A) |
| *b | Port (B) |
| *c | Air |