Home › General › SPECIFICATIONS › 2AR-FE COOLING

2AR-FE COOLING > SERVICE DATA



THERMOSTAT 
Condition
Specified Condition
Standard valve opening temperature
80 to 84°C (176 to 183°F)
Standard valve lift
10 mm (0.394 in.) or more at 95°C (203°F)

COOLING FAN MOTOR 
Item
Condition
Specified Condition
Cooling fan motor (for TMC, TMMR Made)
Battery voltage applied at 20°C (68°F)
5.8 to 7.4 A
Cooling fan motor (for TMMK Made)
Battery voltage applied at 20°C (68°F)
7.4 to 11.4 A
No. 2 cooling fan motor (for TMC, TMMR Made)
Battery voltage applied at 20°C (68°F)
5.8 to 7.4 A
No. 2 cooling fan motor (for TMMK Made)
Battery voltage applied at 20°C (68°F)
7.4 to 11.4 A

RELAY 
Item
Tester Connection
Specified Condition
Fan relay
3 - 4
Below 1 Ω
(Battery voltage not applied between terminals 1 and 2)
3 - 5
10 kΩ or higher
(Battery voltage not applied between terminals 1 and 2)
3 - 4
10 kΩ or higher
(Battery voltage is applied between terminals 1 and 2)
3 - 5
Below 1 Ω
(Battery voltage is applied between terminals 1 and 2)

RADIATOR 
Item
Condition
Specified Condition
Radiator cap
Standard value (for brand-new cap)
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
Minimum standard value (for used cap)
78.5 kPa (0.8 kgf/cm2, 11.4 psi)