Home › General › SPECIFICATIONS › 6AR-FSE COOLING

6AR-FSE COOLING > SERVICE DATA



THERMOSTAT 
Condition
Specified Condition
Standard valve opening temperature
80 to 84°C (176 to 183°F)
Standard valve lift
10 mm (0.394 in.) or more at 95°C (203°F)

COOLING FAN MOTOR 
Item
Condition
Specified Condition
Cooling fan motor
Battery voltage applied at 20°C (68°F)
5.5 to 7.5 A
No. 2 cooling fan motor
Battery voltage applied at 20°C (68°F)
5.5 to 7.5 A

RELAY 
Item
Tester Connection
Specified Condition
Fan relay
3 - 4
Below 1 Ω
(Battery voltage not applied between terminals 1 and 2)
3 - 5
10 kΩ or higher
(Battery voltage not applied between terminals 1 and 2)
3 - 4
10 kΩ or higher
(Battery voltage is applied between terminals 1 and 2)
3 - 5
Below 1 Ω
(Battery voltage is applied between terminals 1 and 2)

RADIATOR 
Item
Condition
Specified Condition
Radiator cap sub-assembly
Standard pressure (for brand-new radiator cap subassembly)
93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18.0 psi)
Minimum pressure (for used radiator cap subassembly)
79 kPa (0.8 kgf/cm2, 11.5 psi)