DTC B27A5 Open in Front Floor Electrical Key Oscillator Circuit |
| DTC Code | DTC Detection Condition | Trouble Area | DTC Output Confirmation Operation |
| B27A5 | An open circuit is detected in the circuit between the certification ECU (smart key ECU assembly) and No. 1 indoor electrical key antenna assembly (front floor) (CLG5 - CLG3*1 or ANTE5*2, CG5B - CLGB) (1 trip detection logic**3). |
| Any time |
| Vehicle Condition when Malfunction Detected | Fail-safe Operation when Malfunction Detected |
When electrical key transmitter sub-assembly is in front seat area:
| - |
| DTC Code | Data List and Active Test |
| B27A5 | Key diagnostic mode can be used to perform troubleshooting |

| 1.CHECK CONNECTOR CONNECTION |
Turn the engine switch off.
Check that the connectors are properly connected to the certification ECU (smart key ECU assembly) and No. 1 indoor electrical key antenna assembly (front floor).
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - NO. 1 INDOOR ELECTRICAL KEY ANTENNA) |
Disconnect the I78 certification ECU (smart key ECU assembly) connector.
Disconnect the I46 No. 1 indoor electrical key antenna assembly (front floor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I78-3 (CLG5) - I46-1 (CLG3) | Always | Below 1 Ω |
| I78-2 (CG5B) - I46-3 (CLGB) | Always | Below 1 Ω |
| A43-11 (E) - Body ground | Always | Below 1 Ω |
| I78-3 (CLG5) or I46-1 (CLG3) - Body ground | Always | 10 kΩ or higher |
| I78-2 (CG5B) or I46-3 (CLGB) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| I78-3 (CLG5) - I46-1 (ANTE5) | Always | Below 1 Ω |
| I78-2 (CG5B) - I46-3 (CLGB) | Always | Below 1 Ω |
| A43-11 (E) - Body ground | Always | Below 1 Ω |
| I78-3 (CLG5) or I46-1 (ANTE5) - Body ground | Always | 10 kΩ or higher |
| I78-2 (CG5B) or I46-3 (CLGB) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) (OUTPUT TO NO. 1 INDOOR ELECTRICAL KEY ANTENNA) |
Connect the I78 certification ECU (smart key ECU assembly) connector.

| *1 | Waveform | - | - |
| *a | Component with harness connected (Certification ECU (smart key ECU assembly)) | *b | Within approximately 30 seconds from when the door is closed |
| *c | After approximately 30 seconds from when the door is closed | - | - |
Connect the I46 No. 1 indoor electrical key antenna assembly (front floor) connector.
Using an oscilloscope, check the waveform.
| Tester Connection | Switch Condition | Tool Setting | Specified Condition |
| I78-3 (CLG5) - A43-11 (E) | Procedure:
| 2 V/DIV., 500 ms/DIV. | Pulse generation (See waveform) |
| I78-2 (CG5B) - A43-11 (E) | Procedure:
| 2 V/DIV., 500 ms/DIV. | Pulse generation (See waveform) |
|
| ||||
| OK | |
| 4.REPLACE NO. 1 INDOOR ELECTRICAL KEY ANTENNA ASSEMBLY (FRONT FLOOR) |
Temporarily replace the No. 1 indoor electrical key antenna assembly (front floor) with a new or known good one (Click here).
| NEXT | |
| 5.CLEAR DTC |
Clear the DTCs (Click here).
| NEXT | |
| 6.CHECK FOR DTC |
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||