BLIND SPOT MONITOR SYSTEM > OPERATION CHECK |
| BLIND SPOT MONITOR BEAM AXIS INSPECTION |
Procedure to enter Test Mode
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the blind spot monitor main switch (warning canceling switch assembly) on.
Turn the GTS on.
Switch the blind spot monitor sensor to Test Mode using the GTS. Enter the following menus: Body Electrical / Blind Spot Monitor Master or Blind Spot Monitor Slave / Utility / BSM Master beam axis inspection or BSM Slave beam axis inspection.
Finish Test Mode.
| BLIND SPOT MONITOR BEAM AXIS CONFIRMATION |
When performing the blind spot monitor beam axis confirmation, move the vehicle to a place where the space shown in the illustration can be secured.

Place the reflector.
Hang a string (with weight) from the center of the vehicle's rear emblem. Mark the vehicle's rear center point on the ground. Repeat for the front of the vehicle. (mark (A) and (B))
![]() |
Draw a vehicle center line so that it passes through mark (A) and (B) (front and rear center points).
![]() |
Mark the position on the center line 593 mm (1.94 ft.) behind the rear bumper (for LH). (Mark (C))
| *a | for LH |
![]() |
Mark the position on the center line 589 mm (1.93 ft.) behind the rear bumper (for RH). (Mark (C))
| *a | for RH |
![]() |
Prepare 2 pieces of string of 600 mm (1.97 ft.) in length and secure the end of each string at a point 300 mm (11.8 in.) from mark (C) as shown in the illustration.
Pull the end of each string and mark the position where each string meets on both the left and right side (marks (D) and (E)).

![]() |
Draw a line (P) so that it passes through mark (D) and (E) and is perpendicular to the vehicle center line.
Set the reflector at the position (Z) shown in the illustration below.

![]() |
| A | |
| Blind spot monitor sensor RH | 465 mm (1.52 ft.) |
| Blind spot monitor sensor LH | 653 mm (2.14 ft.) |
![]() |
Perform the blind spot monitor beam axis display.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the blind spot monitor main switch (warning canceling switch assembly) on.
Turn the GTS on.
Enter the following menus: Body Electrical / Blind Spot Monitor Master or Blind Spot Monitor Slave / Utility / BSM Master beam axis display or BSM Slave beam axis display.
Check the results displayed for the BSM beam axis display.
| Item | Blind Spot Monitor Sensor RH (Master) | Blind Spot Monitor Sensor LH (Slave) |
| Angle | -3.6 to +3.6 ° | -3.6 to +3.6 ° |
| Distance | 2.0 to 3.0 m (6.56 to 9.84 ft.) | 2.0 to 3.0 m (6.56 to 9.84 ft.) |
Perform the blind spot monitor beam axis adjustment using the GTS. Enter the following menus: Body Electrical / Blind Spot Monitor Master or Blind Spot Monitor Slave / Utility / BSM Master beam axis adjustment or BSM Slave beam axis adjustment.
| BLIND SPOT MONITOR INSTALLATION CONDITION INSPECTION |
Remove the rear bumper (Click here).
Attach a jig similar to the one shown in the illustration to the outward facing surface of the blind spot monitor sensor and check that the blind spot monitor sensor is perpendicular to the floor surface or within the allowable range.


| A | B | |
| Blind spot monitor sensor RH | 8 mm (0.315 in) | -8 mm (-0.315 in) |
| Blind spot monitor sensor LH | 0 mm (0.0 in) | -17 mm (-0.669 in) |
![]() |
Using the sensor installation stud bolt center lines as a reference, check that the stud bolts are as shown in the illustration.
| Dimension | Specified Value |
| y | 29 to 42 mm (1.14 to 1.65 in) |