ION GENERATOR > REMOVAL |
| 1. REMOVE INSTRUMENT PANEL SAFETY PAD ASSEMBLY |
| 2. REMOVE HEATER TO REGISTER DUCT ASSEMBLY (for LHD) |
![]() |
Remove the clip.
Remove the 3 screws <D>.
Disengage the heater to register duct assembly from the ion generator assembly, to remove the heater to register duct.
| 3. REMOVE HEATER TO REGISTER DUCT ASSEMBLY (for RHD) |
![]() |
Remove the clip.
Remove the 3 screws <D>.
Disengage the heater to register duct assembly from the ion generator assembly, to remove the heater to register duct.
| 4. REMOVE ION GENERATOR SUB-ASSEMBLY WITH BRACKET |
![]() |
Remove the 3 screws and ion generator sub-assembly with bracket.
| *A | for LHD |
| *B | for RHD |
| 5. REMOVE NO. 1 AIR PURIFIER AIR DUCT |
![]() |
Disengage the 2 claws to remove the No. 1 air purifier air duct.
| *A | for LHD |
| *B | for RHD |
| 6. REMOVE ION GENERATOR SUB-ASSEMBLY |
![]() |
Remove the 3 screws and ion generator sub-assembly.
| *A | for LHD |
| *B | for RHD |