Home › Engine / Hybrid System · 6AR-FSE › FUEL › FUEL PUMP

FUEL PUMP > INSPECTION

for Preparation Click here



1. INSPECT FUEL PUMP


    A288171E03
  1. Check the resistance.

    1. Measure the resistance according to the value(s) in the table below.
      Standard Resistance: 
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      20°C (68°F)
      0.2 to 3.0 Ω
      If the result is not as specified, replace the fuel pump.

  1. Check fuel pump operation.

    1. Apply battery voltage to terminals 1 and 2. Check that the fuel pump operates.

      NOTICE:
      1. Perform this test within 10 seconds to prevent the coil from burning out.
      1. Keep the fuel pump as far away from the battery as possible.
      1. Always switch the voltage on and off at the battery side, not the fuel pump side.

      If the fuel pump does not operate, replace the fuel pump.